AI summary

100% confidence

MES research in electrode, bacteria. Reliable and accurate in situ sensors capable of detecting and quantifying troublesome marine biofil...

Generated by MESSAI extraction pipeline · review against source PDF

Extraction

Reported parameters

3 extracted values

View extracted values

No 3D model is mapped to this paper yet. Parameter ranges above still place reported values on the literature distribution.

Abstract

Reliable and accurate in situ sensors capable of detecting and quantifying troublesome marine biofilms on metallic surfaces are increasingly necessary. A 0.2 mm diameter gold electrochemical sensor was fully characterized using cyclic voltammetry in abiotic and biotic artificial seawater media within a continuous culture flow cell to detect the growth and development of an aerobic Pseudoalteromonas sp. biofilm. Deconvolution of the abiotic and biotic responses enable the constituent extracellular electron transfer and biofilm responses to be resolved. Differentiation of enhanced oxygen reduction kinetics within the aerobic bacterial biofilm is linked to enzyme and redox mediator activities.

Keywords

BiofilmAbiotic componentCyclic voltammetryRedoxElectron transferElectrochemistry

Identifiers

Journal
ACS Applied Materials & Interfaces
Year
2021