Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MEC

Competition of two highly specialized and efficient acetoclastic electroactive bacteria for acetate in biofilm anode of microbial electrolysis cell

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 70 %Substrat ·pure compound

Zusammenfassung

AbstractMaintaining functional stability of microbial electrolysis cell (MEC) treating wastewater depends on maintaining functional redundancy of efficient electroactive bacteria (EAB) on the anode biofilm. Therefore, investigating whether efficient EAB competing for the same resources (electron donor and acceptor) co-exist at the anode biofilm is key for the successful application of MEC for wastewater treatment. Here, we compare the electrochemical and kinetic properties of two efficient acetoclastic EAB, Geobacter sulfurreducens (GS) and Desulfuromonas acetexigens (DA), grown as monoculture in MECs fed with acetate. Additionally, we monitor the evolution of DA and GS in co-culture MECs fed with acetate or domestic wastewater using fluorescent in situ hybridization. The apparent Monod kinetic parameters reveal that DA possesses higher jmax (10.7 ± 0.4 A/m²) and lower KS, app (2 ± 0.15 mM) compared to GS biofilms (jmax: 9.6 ± 0.2 A/m² and KS, app: 2.9 ± 0.2 mM). Further, more donor electrons are diverted to the anode for respiration in DA compared to GS. In acetate-fed co-culture MECs, DA (98% abundance) outcompete GS for anode-dependent growth. In contrast, both EAB co-exist (DA: 55 ± 2%; GS: 24 ± 1.1%) in wastewater-fed co-culture MECs despite the advantage of DA over GS based on kinetic parameters alone. The co-existence of efficient acetoclastic EAB with high current density in MECs fed with wastewater is significant in the context of functional redundancy to maintain stable performance. Our findings also provide insight to future studies on bioaugmentation of wastewater-fed MECs with efficient EAB to enhance performance.

KI-Zusammenfassung: entspricht dem Abstract (70 % Konfidenz) · mit dem Quell-PDF abgleichen

Zentrale Ergebnisse

  • 4 A/m²) and lower KS, app (2 ± 0.
  • In contrast, both EAB co-exist (DA: 55 ± 2%; GS: 24 ± 1.
  • 1%) in wastewater-fed co-culture MECs despite the advantage of DA over GS based on kinetic parameters alone.
02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 61 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

31 von 60 extrahierten Zeilen modellierbar

  • 1 nicht kanonisiert (kein kanonischer Slug)
  • 17 kein SI-Wert
  • 1 außerhalb physikalischer Grenzen
  • 9 nicht als modellierbar markiert
  • 1 Verifizierer hat den Wert abgelehnt
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Substrateacetate,wastewater—80 %
llm
Current Density9,4A/m²95 %
chronoamperometry
"The T-MECGS-NaAc reactor took longer time (40 h) to produce a peak current of 9.…" · T=30°C, pH(an)=7, substrate=acetate, startupModellierbar
Current Density7,2A/m²95 %
chronoamperometry
"A slight decrease in peak current density was observed by reducing the acetate c…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModellierbar
Current Density9,9A/m²95 %
chronoamperometry
"A slight decrease in peak current density was observed by reducing the acetate c…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModellierbar
Current Density (Areal)10,7A/m²95 %
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModellierbar
Current Density10,6A/m²95 %
chronoamperometry
"The T-MECGS-NaAc reactor took longer time (40 h) to produce a peak current of 9.…" · T=30°C, pH(an)=7, substrate=acetate, startupModellierbar
Coulombic efficiency98%95 %
chronoamperometry
"High CE was observed for both MECDA-NaAc (98 ± 2%) and MECGS-NaAc (>110 ± 10%) f…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModellierbar
Current Density (Areal)9,6A/m²95 %
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModellierbar
Current Density×211A/m²95 %
chronoamperometry
"In the 1st batch of operation, a peak current density of 11 ± 0.2 A/m2 was obser…" · T=30°C, pH(an)=7, substrate=acetate, startupModellierbar
Half Saturation Constant2mM95 %
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateAusgeschlossen: kein SI-Wert
Half Saturation Constant2,9mM95 %
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateAusgeschlossen: kein SI-Wert
Current Density8A/m²95 %
chronoamperometry
"In the 1st batch of operation, a peak current density of 11 ± 0.2 A/m2 was obser…" · T=30°C, pH(an)=7, substrate=acetate, startupModellierbar
Coulombic efficiency110Außerhalb des physikalischen Bereichs, Quelle prüfen%95 %
chronoamperometry
"High CE was observed for both MECDA-NaAc (98 ± 2%) and MECGS-NaAc (>110 ± 10%) f…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateAusgeschlossen: außerhalb physikalischer Grenzen
Coulombic efficiency98%95 %
extrahiert
"High CE was observed for both MECDA-NaAc (98 ± 2%) and MECGS-NaAc (>110 ± 10%) f…" · pH(an)=7, substrate=acetate, batchModellierbar
Yield Coefficient0,051g VSS per g COD90 %
dc-protein assay
"27.9 ± 4.8 d−1 (doubling time of 0.6 ± 0.1 h), 0.051 ± 0.001 g VSS per g COD and…" · T=30°C, pH(an)=7, substrate=acetate, startupAusgeschlossen: kein SI-Wert
Chemical Oxygen Demand (COD) Removal0,065h⁻¹90 %
hplc
"In both reactors, the acetate removal rate followed first-order kinetics with re…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateAusgeschlossen: kein SI-Wert
Chemical Oxygen Demand (COD) Removal88%90 %
cod assay
"When domestic wastewater was used as the main source of carbon and energy, the c…" · T=30°C, pH(an)=7, substrate=domestic wastewater with glucose, steady_stateModellierbar
Coulombic efficiency39%90 %
chronoamperometry
"When domestic wastewater was used as the main source of carbon and energy, the c…" · T=30°C, pH(an)=7, substrate=domestic wastewater with glucose, steady_stateModellierbar
Biofilm Coverage21,7%90 %
fish-clsm
"As observed in the MEC reactors fed with acetate, the relative abundance of D. a…" · T=30°C, pH(an)=7, substrate=domestic wastewater with glucose, steady_stateModellierbar
Biofilm Coverage24%90 %
fish-clsm
"As observed in the MEC reactors fed with acetate, the relative abundance of D. a…" · T=30°C, pH(an)=7, substrate=domestic wastewater with glucose, steady_stateModellierbar
Relative Abundance66%90 %
fish-clsm
"While the influent wastewater feed resulted in other microorganisms growing in t…" · T=30°C, pH(an)=7, substrate=domestic wastewater with glucose, steady_stateModellierbar
Biofilm Coverage44%90 %
fish-clsm
"As observed in the MEC reactors fed with acetate, the relative abundance of D. a…" · T=30°C, pH(an)=7, substrate=domestic wastewater with glucose, steady_stateModellierbar
Coulombic efficiency90%90 %
chronoamperometry
"The profile of current generation in the reactors fed with synthetic medium did …" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModellierbar
Electron Recovery Efficiency0,072e- eq of biomass per e- eq of donor90 %
calculation
"27.9 ± 4.8 d−1 (doubling time of 0.6 ± 0.1 h), 0.051 ± 0.001 g VSS per g COD and…" · T=30°C, pH(an)=7, substrate=acetate, startupAusgeschlossen: kein SI-Wert
Chemical Oxygen Demand (COD) Removal0,076h⁻¹90 %
hplc
"In both reactors, the acetate removal rate followed first-order kinetics with re…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateAusgeschlossen: kein SI-Wert
25 von 60 angezeigt

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

The study employed a combination of monoculture and co-culture experiments in microbial electrolysis cells (MECs) to compare the electrochemical and kinetic properties of two efficient acetoclastic electroactive bacteria (EAB) and monitor their coexistence.

Systemkonfiguration

FeldWert
system typeMEC

Biologische Parameter

FeldWert
microbial communityfor acetate in biofilm anode of microbial electrolysis cell

Leistungskennzahlen

FeldWert
citation count39

Betriebsparameter

FeldWert
substrate["acetate","wastewater"]

Elektrochemische Daten

FeldWert
max current density0.4

Betriebsbedingungen

9 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-128572d4cab6c384307—acetate630—startup—-0.1—
v2-3fdf76465f05c55a307————steady_state—-0.1—
v2-52459fd6cf4ecd10307——500—steady_state—-0.1—
v2-64b476fb8837ceb8307—acetate380—steady_state—-0.1—
v2-7bb46dd8c06db06e—7—acetate380—batch———
v2-89fa3cc9e6625dbc307—domestic wastewater with glucose400—steady_state—-0.1—
v2-92d7114005d87ce7307—acetate——steady_state—-0.1—
v2-bc88eb1c9b58fbe6307—domestic wastewater with glucose600—steady_state—-0.1—
v2-c8658e321c5e20d0307—acetate——startup—-0.1—

Mikrobielle Kinetik

3 Konstanten
OrganismusSubstratParameterWertEinheitKonf.
Geobacter sulfurreducensacetateKs2.9Millimolar97 %
Desulfuromonas acetexigensacetateKs2Millimolar97 %
Geobacter sulfurreducensacetateKs2.9Millimolar80 %

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

50 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

60 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

70 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

89 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MEC

Repräsentatives Modell: MEC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MEC
System
11,0Ampere pro Quadratmeter
Bestes Ergebnis · Stromdichte
bester von 11
61
Extrahierte Werte
2021
Jahr

In diesem Datensatz

Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.

Organismen · 4

Schlagwörter

  • Biofilm
  • Microbial electrolysis cell
  • Anode
  • Competition (biology)
  • Electrolysis
  • Bacteria

Zitieren

Veerraghavulu Sapireddy, Krishna P. Katuri, Ali Muhammad et al. (2021). Competition of two highly specialized and efficient acetoclastic electroactive bacteria for acetate in biofilm anode of microbial electrolysis cell. npj Biofilms and Microbiomes. https://doi.org/10.1038/s41522-021-00218-3

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen