MESSAI.iO
Plattform
  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung
Labor
  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Methodik
Anwendungsfälle
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
Wissen
  • Die Wissenschaft
  • Handbuch
  • Whitepaper
Über uns

Sprache

  • Englishen
  • Deutschde

Plattform

  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung

Labor

  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Demo: Ressourcenrückgewinnung

Unternehmen

  • Über uns
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
  • Whitepaper
  • Handbuch
  • API-Dokumentation

Rechtliches

  • Datenschutz
  • Nutzungsbedingungen
  • Nachweise
  • Kontakt

MESSAI · KI für mikrobielle elektrochemische Systeme · © 2026

Jede Zahl auf dieser Website führt auf eine Quelldatei zurück – /proof

Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

← Zurück zur Forschung

Bio-electrochemical nitrogen removal in wastewater: Coupling anodic ammonium oxidation with hydrogenotrophic denitrification in a microbial electrolysis cell.

Bioelectrochemistry (Amsterdam, Netherlands)·2025·doi.org/40946441
Interaktives 3D-ModellKI-angereichert· 75 %
SystemMEC

KI-Zusammenfassung

75 % Konfidenz

This MEC study investigates Anaerobic digestion, Bio-electrochemical systems, Hydrogenotrophic denitrification. The research focuses on system optimization and characterization.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Generic MECProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →

Was gemacht wurde

Systemtyp
MEC

Was funktioniert hat

Noch keine Ergebniskennzahlen extrahiert.

Zusammenfassung

The increasing need for efficient nitrogen removal in wastewater treatment has driven interest in innovative biological and electrochemical approaches that can simultaneously address ammonium and nitrate contamination. This study explored the performance of simultaneous anodic ammonium oxidation and hydrogenotrophic denitrification in a single-chamber microbial electrolysis cell (MEC). Different operational conditions, including varying ammonia‑nitrogen/nitrate‑nitrogen ratios, were selected to evaluate the MEC's ability to promote anaerobic ammonium oxidation along with organic matter removal. The results demonstrated that the single-stage MEC achieved 57.8 % total nitrogen removal efficiency under an optimal condition where the influent contained only ammonium nitrogen at 200 mg/L with no added nitrate. Adding nitrate in the influent of the microbial electrolysis system decreased ammonium removal in all the operational conditions. Additionally, chemical oxygen demand (COD) destruction and methane production occurred uninterrupted throughout all experimental stages. Therefore, simultaneous methane production and nitrogen removal was realized in this study. The microbial electrolysis system achieved 97.3 ± 0.5 % nitrate removal, outperforming the hydrogenotrophic anaerobic digestion system. While no nitrite accumulation was observed in the systems, nitrous oxide emission occurred in all the operational conditions. A microbial community analysis showed that the anode of the MEC reactor was dominated by Pseudothauera and clostridium, which explained the denitrification performance by the MEC. This highlights the potential of bioelectrochemical systems for simultaneous ammonium and nitrate removal in a single-stage wastewater treatment process.

Schlagwörter

Anaerobic digestionBio-electrochemical systemsHydrogenotrophic denitrificationRemoval efficiencySimultaneous nitrification/denitrification

Kennungen

DOI
40946441
PubMed
40946441
Zeitschrift
Bioelectrochemistry (Amsterdam, Netherlands)
Jahr
2025
Generic MECProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →