Enhanced Swine Wastewater Treatment by Constructed Wetland—Microbial Fuel Cell Systems

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 72 %

Zusammenfassung

This paper studies the effects of planting plants and coupled microbial fuel cells (MFCs) on the decontamination capacity and purification mechanism of constructed wetlands (CWs). Four systems were set, namely CW-without plants (A1), CW-with plants (A2), CW-MFC-without plants (A3) and CW-MFC-with plants (A4). The daily reductions per unit area of chemical oxygen demand (COD) were 48.72 ± 5.42, 51.26 ± 4.10, 53.49 ± 5.44 and 58.54 ± 4.16 g·(d·m²)−1, respectively. The daily reductions per unit area of nitrogen (N) were 11.89 ± 0.73, 12.38 ± 0.76, 12.24 ± 0.79 and 13.61 ± 1.07 g·(d·m²)−1, respectively. After studying the pollutant removal efficiency, it was found that the unit area of A4 removes the highest number of pollutants, improving the area efficiency of the wetland system and fundamentally alleviating the disadvantage of the large land footprint of wetland processes. The average output voltages of A3 and A4 were 568.29 and 717.46 mV, respectively, and the maximum power densities were 4.59 and 15.87 mW/m³, respectively. In addition, after high-throughput analysis of microbial samples, anaerobic ammonia oxidising (anammox) bacteria were found to remove N from the system in the anaerobic anode region.

KI-Zusammenfassung

72 % Konfidenz

This paper couples a microbial fuel cell (MFC) with an integrated vertical-flow constructed wetland (IVCW) treating swine wastewater in four configurations: no plants/open circuit (A1), plants/open circuit (A2), no plants/closed circuit (A3), and plants/closed circuit (A4). The best system (A4) achieved 83.07% COD removal (58.54 g/(d·m²)), 73.39% total N removal (13.61 g/(d·m²)), and 717.46 mV output voltage with 15.87 mW/m³ power density. Anammox bacteria in the anaerobic anode region were identified as a key nitrogen removal pathway, consuming NH₄⁺-N and NO₂⁻-N simultaneously under low C/N ratio (~4) conditions.

Zentrale Erkenntnisse

  • Zielkonflikt Synergistic coupling of plants and closed-circuit MFC in A4 removed 9.81 g/(d·m²) COD daily, exceeding the sum of individual improvements from A2 (2.53 g/(d·m²)) and A3 (4.76 g/(d·m²)) by 34.6%, indicating non-additive synergy.

    Was heißt das. Design coupled CW-MFC systems with both plants and closed-circuit operation rather than optimizing either feature alone; the interaction amplifies pollutant removal per unit area.

  • Schwellenwert Anammox bacteria (Candidatus Hydrogenedens and Candidatus Kuenenia) dominated the anode in closed-circuit systems (A3, A4), consuming NH₄⁺ and NO₂⁻ simultaneously at COD <500 mg/L and C/N ratio ~4, with NO₃⁻ and NO₂⁻ accumulation 30–40% lower in A4 than A2.

    Was heißt das. Maintain anode COD <500 mg/L and C/N ratio near 4 to enable anammox; this pathway reduces N₂O risk and improves TN removal without external aeration.

  • Zielkonflikt Plant root oxygenation in A2 and A4 caused NO₃⁻-N and NO₂⁻-N accumulation (A2: 14.87 mg/L NO₃⁻-N, A4: 12.34 mg/L) due to nitrification in the upflow region competing with denitrification, whereas A1 and A3 showed lower accumulation (10.36 and 11.64 mg/L respectively).

    Was heißt das. In planted systems, manage root-zone oxygen gradients to balance nitrification and denitrification; consider recirculation or staged aeration to prevent NO₃⁻ accumulation.

  • Mechanismus Closed-circuit operation (A3, A4) reduced NO₂⁻-N accumulation to 0.021–0.032 mg/L versus 0.031–0.043 mg/L in open-circuit systems (A1, A2), suggesting the electrode acts as an electron acceptor for denitrification.

    Was heißt das. Operate MFC in closed-circuit mode to suppress NO₂⁻ accumulation; this reduces N₂O precursor formation and improves N removal stability.

  • Leistung Power density increased 3.5-fold from A3 (4.59 mW/m³) to A4 (15.87 mW/m³) when plants were added, while maintaining similar COD removal rates (75.76% vs 83.07%), indicating plants enhance electron transfer without sacrificing organic degradation.

    Was heißt das. Include macrophytes in MFC-coupled wetlands to boost power generation; plant root exudates provide labile carbon for electroactive bacteria without competing for electron transfer.

Widersprüche1

Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.

  • Innerhalb der Publikation Plant-induced nitrification increases NO₃⁻ accumulation, yet A4 (with plants) shows lower NO₃⁻ than A2 (with plants, no MFC).

    Eine Seite

    A2 (plants, open circuit) accumulated NO₃⁻-N at 14.87 mg/L efflluent

    “the NO₃⁻-N and NO₂⁻-N concentrations of A2 and A4 plants were higher than A1 and A3, and the accumulation of NO₃⁻-N and NO₂⁻-N appeared in A2 and A4”
    Andere Seite

    A4 (plants, closed circuit) accumulated NO₃⁻-N at 12.34 mg/L efflluent, despite both having plants

    “the accumulation of NO₃⁻-N and NO₂⁻-N in the closed circuit groups (A3 and A4) was less than in the open circuit groups (A1 and A2)”

    Einordnung der Autoren. The authors resolve this by noting that in A4, the electrode acts as an electron acceptor for denitrification, competing with and partially offsetting the nitrification-driven NO₃⁻ accumulation caused by plant root oxygenation. The closed circuit provides an alternative electron sink that reduces net NO₃⁻ accumulation despite active nitrification.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch No measurement of N₂O or N₂ gas production; anammox pathway is inferred from microbial community composition but not confirmed by gas chromatography or isotope tracing.

    Anammox is claimed as a major N removal pathway (Equation 5 shows N₂ production), but the paper provides no direct evidence of N₂ or N₂O emissions. This is critical for validating the anammox mechanism and assessing environmental impact (N₂O is a potent greenhouse gas).

    Versuch. Measure headspace N₂ and N₂O concentrations using gas chromatography or membrane inlet mass spectrometry (MIMS) in A3 and A4 anode regions; correlate with anammox bacterial abundance and NO₂⁻ consumption rates.

  • Hoch No systematic variation of anode potential, cathode potential, or external resistance; only one fixed external resistance (800 Ω) tested.

    The paper does not explore how electrode potential affects nitrogen cycling. Anammox and denitrification are redox-sensitive; anode potential controls electron availability for denitrification, and cathode potential affects oxygen reduction kinetics. The 800 Ω resistance was not justified or optimized.

    Versuch. Vary external resistance (100–2000 Ω) or apply potentiostatic control (anode −0.2 to −0.4 V vs Ag/AgCl) and measure NH₄⁺, NO₂⁻, NO₃⁻ removal rates, anammox bacterial abundance, and power output to identify optimal operating window.

  • Hoch No measurement of dissolved oxygen (DO) profile along the water flow path; oxygen distribution is inferred from microbial community but not directly measured.

    The paper claims a redox gradient drives nitrification and denitrification, but provides no DO measurements. DO is critical for controlling the balance between nitrification (aerobic) and denitrification (anaerobic), and for understanding why NO₃⁻ accumulates in planted systems.

    Versuch. Profile DO concentration at 5 cm intervals from inlet to outlet in A2 and A4 using optical DO sensors; correlate with nitrification and denitrification rates and microbial distribution.

  • Mittel No variation of C/N ratio or organic loading rate; the paper notes that anammox is inhibited above COD 500 mg/L but does not systematically test this threshold or optimize C/N ratio.

    The paper states 'COD concentration could affect the anaerobic ammonia oxidation process, while the COD exceeded 500 mg/L' and notes C/N ratio ~4 in the anode, but does not experimentally vary these parameters to define the operating window for anammox.

    Versuch. Feed A4 with swine wastewater diluted to achieve anode COD of 300, 500, 700, and 1000 mg/L; measure anammox bacterial abundance, NH₄⁺ and NO₂⁻ removal rates, and N₂O production to quantify the COD inhibition threshold.

  • Mittel No measurement of catholyte pH or anode pH; pH is known to affect nitrification, denitrification, and anammox kinetics, but is not reported.

    Anammox bacteria are sensitive to pH (optimal 6.5–8.0); nitrification and denitrification rates are pH-dependent. The paper does not report pH in any compartment, making it impossible to assess whether pH was a limiting factor or to reproduce the system.

    Versuch. Monitor pH in anode, cathode, and bulk liquid daily; vary influent pH (6.5–8.5) and measure its effect on NH₄⁺ removal, anammox abundance, and power output.

  • Mittel No comparison of different plant species or plant density; only Ipomoea aquatica tested, and plant biomass/root density not quantified.

    The paper claims plants enhance oxygen transfer and provide labile carbon, but does not test whether other macrophytes (e.g., Canna indica, Acorus calamus mentioned in literature) would perform better, or whether root density affects performance.

    Versuch. Replicate A4 with Canna indica, Acorus calamus, and Ipomoea aquatica at two plant densities (e.g., 4 and 8 plants per 0.8 m² footprint); measure root biomass, oxygen release, COD and N removal rates, and power output.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 4 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

0 von 3 extrahierten Zeilen modellierbar

  • 1 nicht kanonisiert (kein kanonischer Slug)
  • 2 kein SI-Wert
ParameterWertEinheitKonfidenzQuelleModellierbar
Substratewastewater—80 %
llm
Anode materialregion—70 %
extrahiert
Ausgeschlossen: kein SI-Wert
Microbial communitywere found to remove n from the system in the anaerobic anode region—50 %
extrahiert
Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Maximum power density15,9mW/m²50 %
extrahiert
Ausgeschlossen: kein SI-Wert

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

Four parallel constructed wetland–MFC systems (A1–A4) were operated in a 2×2 orthogonal design (plants: yes/no; circuit: open/closed) treating swine wastewater (COD 852–1057 mg/L, NH₄⁺-N 170–238 mg/L) at 2-day HRT with 800 Ω external resistance. Anode: stainless-steel mesh wrapping activated carbon (20×20×10 cm, 10–20 cm depth). Cathode: carbon felt (20×20 cm, surface). Samples collected every 2 days from influent, anode (S1, 10 cm above bottom), and effluent; analyzed for COD, NH₄⁺-N, NO₃⁻-N, NO₂⁻-N, TP. Voltage and current measured daily; power density calculated. Microbial community analyzed by 16S rRNA pyrosequencing (Illumina MiSeq, V3-V4 region) at experiment end.

Systemkonfiguration

FeldWert
reactor typeMES
chamber config2-chamber

Biologische Parameter

FeldWert
microbial communitywere found to remove n from the system in the anaerobic anode region

Leistungskennzahlen

FeldWert
citation count12

Betriebsparameter

FeldWert
substrate["wastewater"]

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

38 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

50 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

72 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

63 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MFC

Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MFC
System
15,9Milliwatt pro Quadratmeter
Bestes Ergebnis · Leistungsdichte
4
Extrahierte Werte
2022
Jahr

Schlagwörter

  • Microbial fuel cell
  • Constructed wetland
  • Wastewater
  • Chemical oxygen demand
  • Pollutant
  • Wetland

Zitieren

Yun Zhang, Feng Liu, Yidong Lin et al. (2022). Enhanced Swine Wastewater Treatment by Constructed Wetland—Microbial Fuel Cell Systems. Water. https://doi.org/10.3390/w14233930

Zeitschrift
Water

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.