MESSAI.iO
Plattform
  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung
Labor
  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Methodik
Anwendungsfälle
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
Wissen
  • Die Wissenschaft
  • Handbuch
  • Whitepaper
Über uns

Sprache

  • Englishen
  • Deutschde

Plattform

  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung

Labor

  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Demo: Ressourcenrückgewinnung

Unternehmen

  • Über uns
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
  • Whitepaper
  • Handbuch
  • API-Dokumentation

Rechtliches

  • Datenschutz
  • Nutzungsbedingungen
  • Nachweise
  • Kontakt

MESSAI · KI für mikrobielle elektrochemische Systeme · © 2026

Jede Zahl auf dieser Website führt auf eine Quelldatei zurück – /proof

Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

← Zurück zur Forschung

Submersible microbial fuel cell sensor for monitoring microbial activity and BOD in groundwater: Focusing on impact of anodic biofilm on sensor applicability

Yifeng Zhang, Irini Angelidaki

Biotechnology and Bioengineering·2011·123 Zitationen·doi.org/10.1002/bit.23204
Interaktives 3D-ModellKI-angereichert· 70 %
SystemMFC

KI-Zusammenfassung

70 % Konfidenz

A submersible microbial fuel cell sensor was developed for in situ monitoring of microbial activity and BOD in groundwater, with the presence or absence of anodic biofilm affecting its applicability.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Generic MFCProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →

Was gemacht wurde

Systemtyp
MFC

Was funktioniert hat

Noch keine Ergebniskennzahlen extrahiert.

Zusammenfassung

Abstract A sensor, based on a submersible microbial fuel cell (SUMFC), was developed for in situ monitoring of microbial activity and biochemical oxygen demand (BOD) in groundwater. Presence or absence of a biofilm on the anode was a decisive factor for the applicability of the sensor. Fresh anode was required for application of the sensor for microbial activity measurement, while biofilm‐colonized anode was needed for utilizing the sensor for BOD content measurement. The current density of SUMFC sensor equipped with a biofilm‐colonized anode showed linear relationship with BOD content, to up to 250 mg/L (∼233 ± 1 mA/m 2 ), with a response time of <0.67 h. This sensor could, however, not measure microbial activity, as indicated by the indifferent current produced at varying active microorganisms concentration, which was expressed as microbial adenosine‐triphosphate (ATP) concentration. On the contrary, the current density (0.6 ± 0.1 to 12.4 ± 0.1 mA/m 2 ) of the SUMFC sensor equipped with a fresh anode showed linear relationship, with active microorganism concentrations from 0 to 6.52 nmol‐ATP/L, while no correlation between the current and BOD was observed. It was found that temperature, pH, conductivity, and inorganic solid content were significantly affecting the sensitivity of the sensor. Lastly, the sensor was tested with real contaminated groundwater, where the microbial activity and BOD content could be detected in <3.1 h. The microbial activity and BOD concentration measured by SUMFC sensor fitted well with the one measured by the standard methods, with deviations ranging from 15% to 22% and 6% to 16%, respectively. The SUMFC sensor provides a new way for in situ and quantitative monitoring contaminants content and biological activity during bioremediation process in variety of anoxic aquifers. Biotechnol. Bioeng. 2011;108: 2339–2347. © 2011 Wiley Periodicals, Inc.

Zentrale Ergebnisse

  • ▸The sensor showed a linear relationship between current density and BOD content up to 250 mg/L.
  • ▸The sensor equipped with a biofilm-colonized anode could not measure microbial activity.
  • ▸The sensor equipped with a fresh anode showed a linear relationship between current density and active microorganism concentrations.

Schlagwörter

Microbial fuel cellBiofilmGroundwaterEnvironmental chemistryAnodeEnvironmental engineering

Kennungen

DOI
10.1002/bit.23204
Zeitschrift
Biotechnology and Bioengineering
Jahr
2011
Generic MFCProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →