Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Publikation · MFC
Enhancement of microbial fuel cell performance by anodic communities adaptation and cathodic mixed nickel copper oxides (NiO-CuO) on graphene electrocatalyst
Zusammenfassung
Was die Publikation berichtet, in ihren eigenen Worten.
Zusammenfassung
Abstract Mixed transition metal (Ni & Cu) oxides supported on graphene (NiO-CuO/G) electrocatalyst was fabricated and tested as an efficient and cost-effective cathode for oxygen reduction reaction (ORR) in microbial fuel cells (MFCs). The electrocatalytic activity and selectivity of the NiO-CuO/G for ORR were examined using linear sweep voltammetry measurements (LSV) on a rotating disc electrode (RDE) in pH-neutral electrolyte. In comparison with a benchmark platinum cathode, the NiO-CuO/G showed high selectivity towards the ORR. The analysis of Koutecky-Levich relationship suggests that the electrocatalyst follows the four-electron ORR pathway. NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density 21.25 mWm − 2 compared to 50.4 mW m − 2 for Pt/C. Both scanning and transmission electron microscope analyses of anodic biofilm showed that a thick biofilm was successfully developed with a rod-like shape. Biochemical characterization of the communities showed that four genera named Escherichia coli ( E-coli ), Shewanella putrefaciens , Bacillus cereus and Bacillus Thuringiensis/mycoides , which belonging to GammaProteobacteria and Firmicutesphyla thatwerethe most abundant bacteria in the anodic biofilm. Our results revealed that NiO-CuO/G cathode demonstrates an enhanced electrocatalytic activity toward ORR in a pH-neutral solution; thus, the newly developed mixed transition metal oxides electrocatalyst can replace other expensive Pt-based catalysts for MFC application.
KI-Zusammenfassung: entspricht dem Abstract (70 % Konfidenz) · mit dem Quell-PDF abgleichen
Extrahierte Werte
Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.
n = 47 extrahierte Werte
Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.
30 von 47 extrahierten Zeilen modellierbar
- 4 nicht kanonisiert (kein kanonischer Slug)
- 9 kein SI-Wert
- 4 Verifizierer hat den Wert abgelehnt
| Parameter | Wert | Einheit | Konfidenz | Quelle | Anmerkungen | Modellierbar |
|---|---|---|---|---|---|---|
| Substrate Concentration | 1.470 | mg/L | 95 % | gravimetric calculation | "MFCs were fed with artificial wastewater containing: sodium acetate (2gL-1) as t…" · T=25°C, pH(an)=7.2, substrate=sodium acetate | Modellierbar |
| Reactor Volume | 100 | ml | 95 % | geometric measurement | "All MFCs experiments were conducted using single-chamber, air-cathode MFCs (6 cm…" · condition_hint=MFC design parameter | Modellierbar |
| Electrode Spacing | 5 | cm | 95 % | geometric measurement | "They were positioned in the other side of the chamber (perpendicularly to the ca…" · condition_hint=MFC design parameter | Modellierbar |
| Catalyst Loading | 0,3 | mg/cm² | 95 % | gravimetric measurement | "The gas-diffusion carbon cloth electrodes were used as cathode electrode (6 x 6 …" · condition_hint=cathode design parameter, electrode_material=carbon cloth cathode | Ausgeschlossen: kein SI-Wert |
| Electrode Surface Area | 18,5 | cm² | 95 % | geometric measurement | "They had an effective dimension of 2.5 x 2.5 x 0.6 cm and the projected surface …" · condition_hint=anode electrode design parameter, electrode_material=carbon felt | Modellierbar |
| Electrode Surface Area | 0,196 | cm² | 95 % | geometric measurement | "The working electrode (with a geometrical surface area 0.196 cm2) was either NiO…" · condition_hint=RDE electrode design parameter, electrode_material=glassy carbon disk | Modellierbar |
| Substrate Concentration | 50 | mM | 95 % | gravimetric preparation | "The cyclic voltammogram (CV) experiments were conducted in 50mM phosphate buffer…" · T=25°C, pH(an)=7.2 | Ausgeschlossen: kein SI-Wert |
| Electrode Surface Area | 16,6 | cm² | 95 % | geometric measurement | "The gas-diffusion carbon cloth electrodes were used as cathode electrode (6 x 6 …" · condition_hint=cathode electrode design parameter, electrode_material=carbon cloth | Modellierbar |
| Power Density | 21,3 | mWm⁻² | 95 % | extrahiert | "NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, fed_batch | Ausgeschlossen: kein SI-Wert |
| Internal Resistance | 12.000 | Ω | 90 % | polarization curve linear regression | "The internal resistance of NiO-CuO/G (11955 Ω) is slightly higher than the Pt/C …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Voltage | 720 | mV | 90 % | polarization curve | "The maximum voltage output of NiO-CuO/G-based MFC is slightly lower than that of…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Open Circuit Voltage | 654 | mV | 90 % | open-circuit voltage measurement | "After 62 days of operation, MFCs exhibited a stable OCV of 835mV for Pt/C-based …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Voltage | 541 | mV | 90 % | polarization curve | "The maximum voltage output of NiO-CuO/G-based MFC is slightly lower than that of…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Coulombic efficiency | 25 | % | 90 % | coulombic efficiency calculation | "Pt/C shows significantly higher Coulombic efficiency (CE) (35 ± 0.69%) than NiO-…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Internal Resistance | 9.470 | Ω | 90 % | polarization curve linear regression | "The internal resistance of NiO-CuO/G (11955 Ω) is slightly higher than the Pt/C …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Coulombic efficiency | 35 | % | 90 % | coulombic efficiency calculation | "Pt/C shows significantly higher Coulombic efficiency (CE) (35 ± 0.69%) than NiO-…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Open Circuit Voltage | 835 | mV | 90 % | open-circuit voltage measurement | "After 62 days of operation, MFCs exhibited a stable OCV of 835mV for Pt/C-based …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Onset Potential | 400 | mV | 90 % | linear sweep voltammetry | "Although the onset potential of Pt/C has a more positive onset potential (400 mV…" · T=25°C, pH(an)=7.2 | Ausgeschlossen: kein SI-Wert |
| Onset Potential | 163 | mV | 90 % | linear sweep voltammetry | "Although the onset potential of Pt/C has a more positive onset potential (400 mV…" · T=25°C, pH(an)=7.2 | Ausgeschlossen: kein SI-Wert |
| Chemical Oxygen Demand (COD) Removal | 92 | % | 90 % | cod assay | "In the case of NiO-CuO/G-based MFC, the COD removal percentage (92 ± 1.1%) was s…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Electron Recovery Efficiency | 3,94 | — | 90 % | koutecky-levich equation | "It is calculated from to be 3.94 at -0.1 V and 4 at − 0.4 V in case of Pt/C" · T=25°C, pH(an)=7.2 | Modellierbar |
| Electron Recovery Efficiency | 4 | — | 90 % | koutecky-levich equation | "It is calculated from to be 3.94 at -0.1 V and 4 at − 0.4 V in case of Pt/C" · T=25°C, pH(an)=7.2 | Modellierbar |
| Chemical Oxygen Demand (COD) Removal | 93 | % | 90 % | cod assay | "In the case of NiO-CuO/G-based MFC, the COD removal percentage (92 ± 1.1%) was s…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Power Density | 50,4 | mW/m² | 85 % | polarization curve | "NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
| Power Density | 50,4 | mW/m² | 85 % | polarization curve | "Pt/C cathode exhibited a maximum power density generation of 50.4 mWm− 2 at a ce…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_state | Modellierbar |
Methodik
Welches System und wie es betrieben wurde
Methodik
Methodology
The study used linear sweep voltammetry measurements and scanning and transmission electron microscopy to analyze the electrocatalytic activity and selectivity of the NiO-CuO/G electrocatalyst.
Systemkonfiguration
| Feld | Wert |
|---|---|
| chamber configuration | air-cathode |
| system type | MFC |
Elektrodenspezifikationen
| Feld | Wert |
|---|---|
| materials | ["graphene","platinum","copper","nickel"] |
Biologische Parameter
| Feld | Wert |
|---|---|
| microbial community | </italic> and <italic>firmicutesphyla</italic>thatwerethe most abundant bacteria in the anodic biofilm |
Betriebsbedingungen
9 Läufe extrahiert| Lauf | T°C | pHAnolyt | pHKatholyt | Substrat | [S]mg/L | HRTh | Modus | R_extΩ | V_appV | Inokulum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-07f45d82675bae2a | 25 | 7.2 | — | — | — | — | — | — | -0.4 | — |
| v2-0aae13cf23c31a02 | 25 | 7.2 | — | — | — | — | — | — | -0.1 | — |
| v2-0ba7c96606152ee4 | 25 | 7.2 | — | — | — | — | — | — | -0.6 | — |
| v2-18e0dd258c3f7bd6 | 25 | 7.2 | — | sodium acetate | 2000 | — | steady_state | 1000 | — | — |
| v2-25d3f85871ac2ebb | 25 | 7.2 | — | sodium acetate | 2000 | — | fed_batch | — | — | — |
| v2-43ec39334e9263ec | 25 | 7.2 | — | sodium acetate | 2000 | — | steady_state | — | — | — |
| v2-446a181dd772387a | 25 | 7.2 | — | — | — | — | — | — | — | — |
| v2-d06a1c96eea6cd40 | 25 | 7.2 | — | sodium acetate | 2000 | — | — | — | — | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Extraktionspipeline
Rohextraktionen, Artefakte, Qualitätssignal
Extraktionsqualität
EhrlichkeitssignalBemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.
Parametervollständigkeit
38 %
Anteil der erwarteten Parameter, die extrahiert wurden
Datenvollständigkeit
40 %
Gesamtabdeckung der Extraktion über alle Felder
KI-Konfidenz
70 %
Vom Modell selbst angegebene Konfidenz
Mittlere Parameterkonfidenz
85 %
Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen
vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1
Diagramm-Explorer
Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.
Modell erkunden
Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.
KI-Erkenntnisse
Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.
Ähnliche Publikationen vergleichen
Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.
Quell-PDF
Die Publikation, wie sie erschienen ist.
Repräsentatives Modell, generisches MFC
Zum Interagieren tippenRepräsentatives Modell, generisches MFC
Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.
In diesem Datensatz
Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.
Organismen · 1
Schlagwörter
- Electrocatalyst
- Linear sweep voltammetry
- Microbial fuel cell
- Non-blocking I/O
- Cyclic voltammetry
- Cathode
Zitieren
Dena Z Khater, Rabab S Amin, Monera O Zhran et al. (2021). Enhancement of microbial fuel cell performance by anodic communities adaptation and cathodic mixed nickel copper oxides (NiO-CuO) on graphene electrocatalyst. Research Square. https://doi.org/10.21203/rs.3.rs-405277/v1
- Zeitschrift
- Research Square
Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.
Im Labor öffnen