Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MFC

Enhancement of microbial fuel cell performance by anodic communities adaptation and cathodic mixed nickel copper oxides (NiO-CuO) on graphene electrocatalyst

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 70 %Substrat ·pure compound

Zusammenfassung

Abstract Mixed transition metal (Ni & Cu) oxides supported on graphene (NiO-CuO/G) electrocatalyst was fabricated and tested as an efficient and cost-effective cathode for oxygen reduction reaction (ORR) in microbial fuel cells (MFCs). The electrocatalytic activity and selectivity of the NiO-CuO/G for ORR were examined using linear sweep voltammetry measurements (LSV) on a rotating disc electrode (RDE) in pH-neutral electrolyte. In comparison with a benchmark platinum cathode, the NiO-CuO/G showed high selectivity towards the ORR. The analysis of Koutecky-Levich relationship suggests that the electrocatalyst follows the four-electron ORR pathway. NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density 21.25 mWm − 2 compared to 50.4 mW m − 2 for Pt/C. Both scanning and transmission electron microscope analyses of anodic biofilm showed that a thick biofilm was successfully developed with a rod-like shape. Biochemical characterization of the communities showed that four genera named Escherichia coli ( E-coli ), Shewanella putrefaciens , Bacillus cereus and Bacillus Thuringiensis/mycoides , which belonging to GammaProteobacteria and Firmicutesphyla thatwerethe most abundant bacteria in the anodic biofilm. Our results revealed that NiO-CuO/G cathode demonstrates an enhanced electrocatalytic activity toward ORR in a pH-neutral solution; thus, the newly developed mixed transition metal oxides electrocatalyst can replace other expensive Pt-based catalysts for MFC application.

KI-Zusammenfassung: entspricht dem Abstract (70 % Konfidenz) · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 47 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

30 von 47 extrahierten Zeilen modellierbar

  • 4 nicht kanonisiert (kein kanonischer Slug)
  • 9 kein SI-Wert
  • 4 Verifizierer hat den Wert abgelehnt
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Substrate Concentration1.470mg/L95 %
gravimetric calculation
"MFCs were fed with artificial wastewater containing: sodium acetate (2gL-1) as t…" · T=25°C, pH(an)=7.2, substrate=sodium acetateModellierbar
Reactor Volume100ml95 %
geometric measurement
"All MFCs experiments were conducted using single-chamber, air-cathode MFCs (6 cm…" · condition_hint=MFC design parameterModellierbar
Electrode Spacing5cm95 %
geometric measurement
"They were positioned in the other side of the chamber (perpendicularly to the ca…" · condition_hint=MFC design parameterModellierbar
Catalyst Loading0,3mg/cm²95 %
gravimetric measurement
"The gas-diffusion carbon cloth electrodes were used as cathode electrode (6 x 6 …" · condition_hint=cathode design parameter, electrode_material=carbon cloth cathodeAusgeschlossen: kein SI-Wert
Electrode Surface Area18,5cm²95 %
geometric measurement
"They had an effective dimension of 2.5 x 2.5 x 0.6 cm and the projected surface …" · condition_hint=anode electrode design parameter, electrode_material=carbon feltModellierbar
Electrode Surface Area0,196cm²95 %
geometric measurement
"The working electrode (with a geometrical surface area 0.196 cm2) was either NiO…" · condition_hint=RDE electrode design parameter, electrode_material=glassy carbon diskModellierbar
Substrate Concentration50mM95 %
gravimetric preparation
"The cyclic voltammogram (CV) experiments were conducted in 50mM phosphate buffer…" · T=25°C, pH(an)=7.2Ausgeschlossen: kein SI-Wert
Electrode Surface Area16,6cm²95 %
geometric measurement
"The gas-diffusion carbon cloth electrodes were used as cathode electrode (6 x 6 …" · condition_hint=cathode electrode design parameter, electrode_material=carbon clothModellierbar
Power Density21,3mWm⁻²95 %
extrahiert
"NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, fed_batchAusgeschlossen: kein SI-Wert
Internal Resistance12.000Ω90 %
polarization curve linear regression
"The internal resistance of NiO-CuO/G (11955 Ω) is slightly higher than the Pt/C …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Voltage720mV90 %
polarization curve
"The maximum voltage output of NiO-CuO/G-based MFC is slightly lower than that of…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Open Circuit Voltage654mV90 %
open-circuit voltage measurement
"After 62 days of operation, MFCs exhibited a stable OCV of 835mV for Pt/C-based …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Voltage541mV90 %
polarization curve
"The maximum voltage output of NiO-CuO/G-based MFC is slightly lower than that of…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Coulombic efficiency25%90 %
coulombic efficiency calculation
"Pt/C shows significantly higher Coulombic efficiency (CE) (35 ± 0.69%) than NiO-…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Internal Resistance9.470Ω90 %
polarization curve linear regression
"The internal resistance of NiO-CuO/G (11955 Ω) is slightly higher than the Pt/C …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Coulombic efficiency35%90 %
coulombic efficiency calculation
"Pt/C shows significantly higher Coulombic efficiency (CE) (35 ± 0.69%) than NiO-…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Open Circuit Voltage835mV90 %
open-circuit voltage measurement
"After 62 days of operation, MFCs exhibited a stable OCV of 835mV for Pt/C-based …" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Onset Potential400mV90 %
linear sweep voltammetry
"Although the onset potential of Pt/C has a more positive onset potential (400 mV…" · T=25°C, pH(an)=7.2Ausgeschlossen: kein SI-Wert
Onset Potential163mV90 %
linear sweep voltammetry
"Although the onset potential of Pt/C has a more positive onset potential (400 mV…" · T=25°C, pH(an)=7.2Ausgeschlossen: kein SI-Wert
Chemical Oxygen Demand (COD) Removal92%90 %
cod assay
"In the case of NiO-CuO/G-based MFC, the COD removal percentage (92 ± 1.1%) was s…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Electron Recovery Efficiency3,94—90 %
koutecky-levich equation
"It is calculated from to be 3.94 at -0.1 V and 4 at − 0.4 V in case of Pt/C" · T=25°C, pH(an)=7.2Modellierbar
Electron Recovery Efficiency4—90 %
koutecky-levich equation
"It is calculated from to be 3.94 at -0.1 V and 4 at − 0.4 V in case of Pt/C" · T=25°C, pH(an)=7.2Modellierbar
Chemical Oxygen Demand (COD) Removal93%90 %
cod assay
"In the case of NiO-CuO/G-based MFC, the COD removal percentage (92 ± 1.1%) was s…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Power Density50,4mW/m²85 %
polarization curve
"NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
Power Density50,4mW/m²85 %
polarization curve
"Pt/C cathode exhibited a maximum power density generation of 50.4 mWm− 2 at a ce…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, steady_stateModellierbar
25 von 47 angezeigt

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

The study used linear sweep voltammetry measurements and scanning and transmission electron microscopy to analyze the electrocatalytic activity and selectivity of the NiO-CuO/G electrocatalyst.

Systemkonfiguration

FeldWert
chamber configurationair-cathode
system typeMFC

Elektrodenspezifikationen

FeldWert
materials["graphene","platinum","copper","nickel"]

Biologische Parameter

FeldWert
microbial community</italic> and <italic>firmicutesphyla</italic>thatwerethe most abundant bacteria in the anodic biofilm

Betriebsbedingungen

9 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-07f45d82675bae2a257.2——————-0.4—
v2-0aae13cf23c31a02257.2——————-0.1—
v2-0ba7c96606152ee4257.2——————-0.6—
v2-18e0dd258c3f7bd6257.2—sodium acetate2000—steady_state1000——
v2-25d3f85871ac2ebb257.2—sodium acetate2000—fed_batch———
v2-43ec39334e9263ec257.2—sodium acetate2000—steady_state———
v2-446a181dd772387a257.2————————
v2-d06a1c96eea6cd40257.2—sodium acetate2000—————
v2-f586e9af22985397——————————

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

38 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

40 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

70 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

85 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MFC

Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MFC
System
50,4Milliwatt pro Quadratmeter
Bestes Ergebnis · Leistungsdichte
bester von 4
47
Extrahierte Werte
2021
Jahr

In diesem Datensatz

Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.

Schlagwörter

  • Electrocatalyst
  • Linear sweep voltammetry
  • Microbial fuel cell
  • Non-blocking I/O
  • Cyclic voltammetry
  • Cathode

Zitieren

Dena Z Khater, Rabab S Amin, Monera O Zhran et al. (2021). Enhancement of microbial fuel cell performance by anodic communities adaptation and cathodic mixed nickel copper oxides (NiO-CuO) on graphene electrocatalyst. Research Square. https://doi.org/10.21203/rs.3.rs-405277/v1

Zeitschrift
Research Square

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen