Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MFC

Different Types of Microbial Fuel Cell (MFC) Systems for Simultaneous Electricity Generation and Pollutant Removal

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 70 %Substrat ·real wastewaterWastewater TreatmentPower Generation

Zusammenfassung

The aim of this study is to identify the relationship between the rate of electricity generation and the rate of carbon and nitrogen removal from wastewater using different MFC processes. Determining whether the generation of electricity using MFC process could be related to the rate of pollutant removal from wastewater is noteworthy. Three types of MFC process configurations include the batch mode (SS), a continuous flow of influent with ferricyanide (PF) as the oxidizing agent and a continuous flow of influent with oxygen (PU) as the oxidizing agent. The highest quantity of electricity generation was achieved using the continuous flow mode with ferricyanide (0.833 V), followed by the continuous flow mode with oxygen (0.589 V) and the batch mode (0.352 V). The highest efficiency of carbon removal is also achieved by the continuous flow mode with ferricyanide (87%), followed by the continuous flow mode with oxygen (51%) and the batch mode (46%). Moreover, the continuous flow mode with ferricyanide produced the highest efficiency for nitrogen removal (63%), followed by the continuous flow mode with oxygen (54%) and the batch mode (27%).

KI-Zusammenfassung

70 % Konfidenz

Zentrale Erkenntnisse

  • Zielkonflikt Ferricyanide cathode generated 41% higher voltage (0.833 V vs 0.589 V) and 35% higher COD removal (86.69% vs 51.28%) than oxygen cathode under identical continuous-flow anode conditions.

    Was heißt das. If targeting high power output and carbon removal, use ferricyanide as cathode oxidant; oxygen is insufficient despite being cheaper and more practical.

  • Mechanismus Continuous anodic flow improved nitrogen removal from 27% (batch) to 54–63% (continuous), and this improvement was independent of cathode type, suggesting anode mixing is a primary driver of nitrogenous compound degradation.

    Was heißt das. Prioritize anode recirculation or mixing to enhance nitrogen removal; cathode choice modulates magnitude but not the fundamental benefit of continuous flow.

  • Mechanismus Organic nitrogen removal was 0% in batch and 66.67% in continuous-oxygen, but reached 100% in ferricyanide-continuous (PF), while ammonia removal plateaued at ~50% across all systems.

    Was heißt das. Ferricyanide selectively enhances organic nitrogen mineralization but does not improve ammonia oxidation; nitrification or ammonia recovery may require separate intervention.

  • Mechanismus Nitrate reduction was 17.85% (batch), 58.96% (oxygen-continuous), and 63.75% (ferricyanide-continuous), with the paper attributing the oxygen-system lag to oxidation of nitrite back to nitrate under aerated conditions.

    Was heißt das. If targeting denitrification, avoid aeration or use anoxic cathode; ferricyanide's anoxic nature may favor nitrite reduction to N2 over re-oxidation, but nitrite accumulation was not measured.

  • Schwellenwert pH dropped 1.74% (batch), 1.88% (oxygen-continuous), and 5.81% (ferricyanide-continuous) over 240 hr, attributed to denitrification; no pH control was applied.

    Was heißt das. Ferricyanide systems acidify faster; buffer capacity or pH control may be needed to maintain biofilm stability and prevent inhibition, especially in longer runs.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch Nitrite accumulation was not measured in any system, despite denitrification occurring and N2O being a focus of the reading prompt.

    Section 3.4 mentions nitrite oxidation in aerated conditions but provides no nitrite data; ferricyanide system may accumulate nitrite as intermediate, but this was not tracked.

    Versuch. Measure NO2-N (or NO2- in mg/l) at 48 hr intervals in all three systems, especially PF, to determine if ferricyanide cathode favors nitrite reduction to N2 or accumulation.

  • Hoch Cathode potential and anode potential were not independently controlled or reported; only open-circuit voltage and load voltage across resistors were measured.

    Section 2.2 describes voltage measurement but no potentiostat data; operating window for optimal denitrification vs. nitrification cannot be inferred.

    Versuch. Use potentiostat to set cathode potential (e.g., −0.2 to −0.6 V vs. Ag/AgCl) and anode potential (e.g., −0.2 to +0.2 V) independently; measure nitrogen species and power output at each combination.

  • Mittel Hydraulic retention time (HRT) was not explicitly controlled or varied; continuous systems withdrew 200 ml every 48 hr from a ~700 ml anode, but no HRT sensitivity analysis was performed.

    Section 2.2 states sampling protocol but does not report calculated HRT or test its effect on nitrogen removal or voltage.

    Versuch. Vary anode recirculation rate or influent flow rate to achieve HRTs of 2, 5, and 10 days; measure ammonia, nitrate, and power output to identify optimal HRT for denitrification.

  • Mittel C/N ratio was not controlled or reported; wastewater composition was fixed (glucose 1 g/l, ammonia chloride 0.5 g/l) but no sensitivity to C/N variation was tested.

    Section 2.1 describes substrate mix but does not justify C/N ratio or test its effect on nitrogen removal efficiency.

    Versuch. Prepare influent with C/N ratios of 5:1, 10:1, and 20:1 (by mass); measure TKN removal, ammonia removal, and nitrate reduction to identify optimal ratio for each system.

  • Mittel Dissolved oxygen (DO) in the anode compartment was not measured; batch and ferricyanide systems were sealed but no confirmation of anaerobic conditions was provided.

    Section 2.2 states epoxy sealing to ensure anaerobic conditions, but no DO probe data or redox potential measurements confirm this.

    Versuch. Insert DO probe into anode compartment of all three systems; confirm anaerobic conditions (<0.5 mg/l DO) and measure redox potential (Eh) to correlate with nitrogen species transformations.

  • Niedrig Catholyte pH was not controlled; anodic pH dropped 5.81% in ferricyanide system but no pH buffering or control strategy was tested.

    Section 3.5 reports pH change but no intervention; ferricyanide system acidified most, potentially limiting biofilm stability.

    Versuch. Buffer cathode or anode to pH 7.0 ± 0.5 using phosphate buffer; measure voltage, COD removal, and nitrogen removal to assess pH sensitivity.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Zentrale Ergebnisse

  • The highest quantity of electricity generation was achieved using the continuous flow mode with ferricyanide (0.
02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 160 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

98 von 157 extrahierten Zeilen modellierbar

  • 30 nicht kanonisiert (kein kanonischer Slug)
  • 14 kein SI-Wert
  • 12 nicht als modellierbar markiert
  • 1 Physikprüfung nicht bestanden
  • 2 widerspricht anderen Publikationen
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Open Circuit Voltage0,833V90 %
llm
abstract
Substratewastewater—80 %
llm
Designcontinuous flow—80 %
llm
Total Nitrogen Removal×217,9%95 %
nitrate analysis (apha 4500c)
"For the SS system, the reduction in the nitrate was approximately 5 mg/l or 17.8…" · pH(an)=7, substrate=wastewater with glucose, steady_stateAusgeschlossen: widerspricht anderen Publikationen
Maximum Power Point×20,589V95 %
open circuit voltage recording
"The highest voltage generated by the PF system was 0.833 V, whereas the highest …" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Maximum Power Point×20,833V95 %
open circuit voltage recording
"The highest voltage generated by the PF system was 0.833 V, whereas the highest …" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
pH×26,76—95 %
ph measurement
"The pH of the electrolyte dropped to 6.76 (or by 1.74%) in the SS system" · pH(an)=6.76, substrate=wastewater with glucose, steady_stateModellierbar
Organic Nitrogen×20,168mg/l95 %
organic nitrogen analysis (apha 4500c)
"Table 3: Hour 192: 0.168 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Organic Nitrogen Removal Efficiency×2100%95 %
organic nitrogen analysis (apha 4500c)
"100 % of the organic nitrogen is removed" · pH(an)=7, substrate=wastewater with glucose, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Organic Nitrogen Before MFC Operation×21,68mg/l95 %
organic nitrogen analysis (apha 4500c)
"The compositions of nitrogen before the MFC operation were 4.48 mg/l ammonia nit…" · pH(an)=7, substrate=wastewater with glucose, startupAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Organic Nitrogen×21,68mg/l95 %
organic nitrogen analysis (apha 4500c)
"Table 3: Hour 0: 1.68 mg/l" · pH(an)=7, substrate=wastewater with glucose, startupAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Organic Nitrogen Removal Efficiency×266,7%95 %
organic nitrogen analysis (apha 4500c)
"the percentage of organic nitrogen removed is 66.67%" · pH(an)=7, substrate=wastewater with glucose, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Organic Nitrogen×21,12mg/l95 %
organic nitrogen analysis (apha 4500c)
"Table 2: Hour 96: 1.12 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Ammonium Ion Concentration×22,24mg/l95 %
ammonia nitrogen analysis (apha 4500c)
"Table 3: Hour 240: 2.24 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Ammonium Ion Concentration×22,8mg/l95 %
ammonia nitrogen analysis (apha 4500c)
"Table 2: Hour 192: 2.8 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Total Kjeldahl Nitrogen×25,04mg/l95 %
tkn analysis (apha 4500c)
"Table 2: Hour 96: 5.04 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Total Kjeldahl Nitrogen×22,24mg/l95 %
tkn analysis (apha 4500c)
"Table 3: Hour 240: 2.24 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Chemical Oxygen Demand (COD) Removal×246%95 %
cod analysis (apha 5220b)
"and the batch mode (46%)" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Chemical Oxygen Demand (COD) Removal×246,2%95 %
cod analysis (apha 5220b)
"Table 1 shows that the efficiency of COD removal for the three systems. The most…" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Nitrogen Removal×227%95 %
nitrogen analysis (apha 4500c)
"and the batch mode (27%)" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Total Kjeldahl Nitrogen×22,8mg/l95 %
tkn analysis (apha 4500c)
"Table 2: Hour 240: 2.8 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Ammonia Removal Efficiency×250%95 %
ammonia nitrogen analysis (apha 4500c)
"The percentage of nitrogen components removed is higher for the PF system (50% o…" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Total Kjeldahl Nitrogen×22,52mg/l95 %
tkn analysis (apha 4500c)
"Table 3: Hour 144: 2.52 mg/l" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Chemical Oxygen Demand (COD) Removal×387%95 %
cod analysis (apha 5220b)
"The highest efficiency of carbon removal is also achieved by the continuous flow…" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
Chemical Oxygen Demand (COD) Removal×286,7%95 %
cod analysis (apha 5220b)
"Table 1 shows that the efficiency of COD removal for the three systems. The most…" · pH(an)=7, substrate=wastewater with glucose, steady_stateModellierbar
25 von 81 angezeigt

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

The study employed three types of MFC process configurations: batch mode (SS), continuous flow with ferricyanide (PF), and continuous flow with oxygen (PU) to investigate the relationship between electricity generation and pollutant removal.

Leistungskennzahlen

FeldWert
citation count6

Betriebsparameter

FeldWert
substrate["wastewater"]

Betriebsbedingungen

12 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
PF_continuous_ferricyanide——————continuous———
PF_continuous_ferricyanide #2——————continuous———
PU_continuous_oxygen——————continuous———
PU_continuous_oxygen #2——————continuous———
SS_batch——————batch———
SS_batch #2——————batch———
v2-11b9a75e088dca03——————continuous———
v2-474906e4b88f1557—7—wastewater with glucose1000—steady_state———
v2-4769e78b0ead6e18—7—wastewater with glucose1000—startup———
v2-adae3c749d2ca3b8—6.88—wastewater with glucose1000—startup———
v2-be91c0e38e88625c—6.76—wastewater with glucose1000—steady_state———
v2-e901e361c59df443——————batch———

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

38 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

60 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

70 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

94 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell: Einkammer-MFC mit Luftkathode

Repräsentatives Modell: Einkammer-MFC mit Luftkathode – zugeordnet anhand der berichteten Konfiguration der Publikation, nicht ihrer genauen Geometrie.

MFC
System
87,0Prozent
Bestes Ergebnis · CSB-Entfernung
bester von 15
160
Extrahierte Werte
2015
Jahr

In diesem Datensatz

Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.

Organismen · 1

  • mixed culture

Materialien · 1

Schlagwörter

  • Oxidizing agent
  • Ferricyanide
  • Wastewater
  • Volumetric flow rate
  • Pollutant
  • Pulp and paper industry

Zitieren

S. M. Zain, N. L. Ching, S. Jusoh et al. (2015). Different Types of Microbial Fuel Cell (MFC) Systems for Simultaneous Electricity Generation and Pollutant Removal. Jurnal Teknologi. https://doi.org/10.11113/jt.v74.4544

Zeitschrift
Jurnal Teknologi

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen