Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MFC

Enhancing Stability of Microalgae Biocathode by a Partially Submerged Carbon Cloth Electrode for Bioenergy Production from Wastewater

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 78 %Substrat ·real wastewater

Zusammenfassung

The electricity output from microbial fuel cell (MFC) with a microalgae assisted cathode is usually higher than that with an air cathode. The output of electricity from a photosynthetic microalgae MFC was positively correlated with the dissolved oxygen (DO) level in the microalgae assisted biocathode. However, DO is highly affected by the photosynthesis of microalgae, leading to the low stability in the electricity output that easily varies with the change in microalgae growth. In this study, to improve the electricity output stability of the MFC, a partially submerged carbon cloth cathode electrode was first investigated to use oxygen from both microalgae and air, with synthetic piggery wastewater used as the anolyte and anaerobically digested swine wastewater as the catholyte. When the DO levels dropped from 13.6–14.8 to 1.0–1.6 mg/L, the working voltages in the MFCs with partially submerged electrodes remained high (256–239 mV), whereas that for the conventional completely submerged electrodes dropped from 259 to 102 mV. The working voltages (average, 297 ± 26 mV) of the MFCs with the 50% submerged electrodes were significantly (p < 0.05) higher than with other partially or completely submerged electrodes. The associated maximum lipid production from wastewater was 250 ± 42 mg/L with lipid content of 41 ± 6% dry biomass. Although the partially submerged electrode had no significant effects on lipid production or nitrogen removal in wastewater, there was significant improvement in the stability of the electricity generated under variable conditions.

KI-Zusammenfassung

78 % Konfidenz

This study demonstrates that a partially submerged (50%) carbon cloth cathode in a microalgae-assisted microbial fuel cell (MFC) improves voltage stability and power output by accessing both dissolved oxygen from algal photosynthesis and atmospheric oxygen. When DO dropped from 13.6–14.8 to 1.0–1.6 mg/L, the 50% submerged electrode maintained 256–239 mV versus 259–102 mV for fully submerged electrodes. The system achieved 297 ± 26 mV average working voltage, 99 ± 6 mW/m³ power density, and 250 ± 42 mg/L lipid production while removing 75 ± 1% total nitrogen from anaerobically digested swine wastewater, though nitrogen removal was not significantly affected by electrode submersion.

Zentrale Erkenntnisse

  • Schwellenwert Partial submersion (50%) of the cathode electrode reduced voltage variance from ±66 mV (100% submerged) to ±26 mV while maintaining higher average voltage (297 vs 268 mV), demonstrating that dual oxygen access stabilizes performance under variable DO conditions.

    Was heißt das. Operators should target 50% submersion as an operating window to decouple electricity output from microalgae growth phase and light/dark cycles, enabling more predictable power generation in variable wastewater treatment systems.

  • Schwellenwert Working voltage remained stable (256–239 mV) at 25% submersion despite 13.6× drop in DO (13.6–14.8 to 1.0–1.6 mg/L), whereas 100% submerged voltage collapsed to 102 mV, indicating a critical DO threshold below ~2 mg/L where fully submerged electrodes fail.

    Was heißt das. Design cathode systems to operate above 2 mg/L DO if using fully submerged electrodes, or adopt partial submersion to extend stable operation into low-DO regimes (1–2 mg/L) common in late-batch or dark-period conditions.

  • Zielkonflikt Nitrogen removal (TN 75 ± 1%, NH₃-N 63 ± 2%) was not significantly different across submersion levels (p > 0.05), but MFCs outperformed controls (53 ± 4% TN, 44 ± 5% NH₃-N), indicating that electrode geometry does not control N-removal kinetics in this system.

    Was heißt das. Electrode submersion can be optimized for power stability without sacrificing nitrogen removal; focus design trade-offs on voltage/power rather than N-removal, which is driven by microalgae uptake and pH-dependent ammonia speciation.

  • Mechanismus COD/TN ratio improved from 0.7–0.8 (inlet) to 1.7–3.0 (outlet) due to TN removal, approaching the 2.0–2.5 threshold needed for effective denitrification in downstream treatment, but the paper does not measure nitrite or N₂O accumulation.

    Was heißt das. This MFC cathode can serve as a pre-treatment to raise COD/N for downstream denitrification, but operators should monitor for NO₂⁻ or N₂O slip in the cathode itself, which is not reported here.

  • Leistung Internal resistance was lowest (6 ± 0.1 × 10² Ω) and most stable at 50% submersion versus 7 ± 1–2 × 10² Ω for other conditions, correlating with voltage stability but not significantly affecting power density (p > 0.05).

    Was heißt das. Partial submersion reduces ohmic losses and variance, supporting the use of 50% submersion for stable, predictable voltage output in scaled systems.

Widersprüche1

Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.

  • Innerhalb der Publikation Electrode submersion significantly affects voltage stability but not nitrogen removal efficiency

    Eine Seite

    Submersion proportion has significant effect on working voltage (p < 0.05, ANOVA F=23.927)

    “ANOVA analysis also revealed that the effect of submerged proportion on working voltages is significant (p (Sig.) < 0.05, Table A1).”
    Andere Seite

    Submersion proportion has no significant effect on TN and NH₃-N removal (p > 0.05)

    “This finding suggests that the effects for the submerged proportions of the cathode electrode were not significant for the removal efficiencies of nitrogen and COD.”

    Einordnung der Autoren. The authors explain that nitrogen removal is driven by microalgae uptake and pH-dependent ammonia speciation (free ammonia 0.8–20.2% of total), not by electrode oxygen availability. Voltage stability depends on dual oxygen access, which is decoupled from N-removal kinetics in this system.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch No measurement of nitrite (NO₂⁻) or nitrous oxide (N₂O) accumulation in the cathode chamber despite achieving 75% TN removal and raising COD/TN ratio to 2.0–2.4, which are conditions favoring denitrification.

    Section 3.4 states that 'Increasing the COD/N ratio could effectively improve the biological nitrogen removal by denitrification,' but the paper does not measure whether NO₂⁻ or N₂O are produced or accumulated in the cathode. This is critical for assessing true N-removal pathways and greenhouse gas emissions.

    Versuch. Measure NO₃⁻, NO₂⁻, and N₂O in the cathode chamber at 2-day intervals across all submersion levels; use gas chromatography for N₂O and ion chromatography for NO₃⁻/NO₂⁻. Determine if denitrification or nitrification-denitrification is occurring.

  • Hoch No systematic variation of cathode potential or current density to assess their effect on nitrogen speciation or removal pathway selection.

    The paper operates at fixed 1 kΩ external resistance (generating 239–344 mV working voltage) but does not test how cathode potential affects N-removal mechanisms. Denitrification and nitrification are potential-dependent processes; the paper does not explore this trade-off.

    Versuch. Vary external resistance (100 Ω to 10 kΩ) to span cathode potentials from −0.2 to +0.3 V vs. Ag/AgCl. Measure NO₃⁻, NO₂⁻, NH₄⁺, and N₂O at each potential. Identify the potential window for complete denitrification vs. NO₂⁻ accumulation.

  • Mittel No measurement of dissolved oxygen concentration in the anode chamber or assessment of whether partial submersion of the cathode affects anode-side anaerobiosis.

    The paper seals the anode with silicone and parafilm, but does not verify that partial cathode submersion (which increases air exposure) does not compromise anode anaerobiosis. Oxygen leakage could affect anode biofilm composition and acetate oxidation kinetics.

    Versuch. Measure DO in the anode chamber at the start and end of each batch for all submersion levels using a sealed DO probe. Verify that anode remains <0.5 mg/L DO regardless of cathode design.

  • Mittel No exploration of the optimal submersion proportion as a function of DO setpoint or light intensity, which vary with microalgae growth phase and day/night cycles.

    The paper tests fixed submersion levels (25%, 50%, 75%, 100%) but does not investigate whether the optimal submersion should be adjusted dynamically based on real-time DO or light conditions. This limits practical applicability to variable wastewater treatment scenarios.

    Versuch. Implement a feedback control system that adjusts submersion proportion (e.g., via a motorized electrode holder) based on measured DO. Compare voltage stability and average power output to fixed-submersion controls across a 12-hour light/dark cycle.

  • Mittel No characterization of the microbial community (bacteria, archaea) in the cathode chamber, despite operating under non-sterile conditions and achieving high lipid content (41 ± 6%).

    Section 3.3 notes 'negligible presences of bacteria cells' and attributes high lipid content to low contamination, but provides no 16S rRNA or metagenomic data. This limits understanding of whether heterotrophic bacteria compete with microalgae for oxygen or nitrogen, and whether they contribute to denitrification.

    Versuch. Perform 16S rRNA gene sequencing on cathode samples at days 0, 4, 8 of each batch. Quantify bacterial vs. algal biomass. Correlate community composition with nitrogen removal pathway and N₂O production.

  • Niedrig No measurement of pH dynamics in the cathode chamber beyond the statement that pH was adjusted to 7.0 every 2 days; no assessment of how pH variation affects ammonia speciation and nitrogen removal.

    Section 3.4 states that pH increased from 7.0 to 8.3–8.5 between adjustments, and that free ammonia ranged from 0.8–20.2% of total ammonia in this pH range. However, the paper does not measure the kinetics of pH change or its effect on N-removal rate or pathway.

    Versuch. Measure pH continuously (every 2 hours) using an in-situ pH probe. Correlate pH trajectory with ammonia removal rate and nitrogen speciation. Determine if pH control (e.g., via CO₂ sparging) improves N-removal consistency.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 80 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

60 von 79 extrahierten Zeilen modellierbar

  • 1 nicht kanonisiert (kein kanonischer Slug)
  • 18 kein SI-Wert
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Substratewastewater—80 %
llm
Operating Voltage268mV95 %
direct voltage measurement
"the average working voltages for the 25%, 50%, 75%, and 100% submerged electrode…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage278mV95 %
direct voltage measurement
"the average working voltages for the 25%, 50%, 75%, and 100% submerged electrode…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage297mV95 %
direct voltage measurement
"The working voltages (average, 297 ± 26 mV) of the MFCs with the 50% submerged e…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage246mV95 %
direct voltage measurement
"the average working voltages for the 25%, 50%, 75%, and 100% submerged electrode…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage387mV90 %
direct voltage measurement
"Working voltage on 1 kΩ(mV) max 387" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage259mV90 %
direct voltage measurement
"whereas that of the 100% submerged one fell from 259 to 102 mV, when their DO in…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage102mV90 %
direct voltage measurement
"whereas that of the 100% submerged one fell from 259 to 102 mV, when their DO in…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage239mV90 %
direct voltage measurement
"The working voltage in the MFCs with 25% submerged cathode electrodes just chang…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage329mV90 %
direct voltage measurement
"Working voltage on 1 kΩ(mV) max 329" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage344mV90 %
direct voltage measurement
"Working voltage on 1 kΩ(mV) max 344" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage322mV90 %
direct voltage measurement
"Working voltage on 1 kΩ(mV) max 322" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Operating Voltage256mV90 %
direct voltage measurement
"The working voltage in the MFCs with 25% submerged cathode electrodes just chang…" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Lipid Content37%90 %
folch method
"Lipid content (%) max 37 ± 2" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Lipid Content40%90 %
folch method
"Lipid content (%) max 40 ± 3" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Lipid Content34%90 %
folch method
"Lipid content (%) average 34 ± 3" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Biogas Production573mg/L90 %
dry weight measurement
"Biomass production (dry weight, mg/L) average 573 ± 53" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Formic Acid Production Rate199mg/L90 %
folch method
"Lipid production (mg/L) average 199 ± 27" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Lipid Content41%90 %
folch method
"Lipid content (%) max 41 ± 6" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterModellierbar
Biogas Production616mg/L90 %
dry weight measurement
"Biomass production (dry weight, mg/L) max 616 ± 17" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Formic Acid Production Rate214mg/L90 %
folch method
"Lipid production (mg/L) max 214 ± 4" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Biogas Production647mg/L90 %
dry weight measurement
"Biomass production (dry weight, mg/L) max 647 ± 57" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Biogas Production587mg/L90 %
dry weight measurement
"Biomass production (dry weight, mg/L) average 587 ± 83" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Formic Acid Production Rate206mg/L90 %
folch method
"Lipid production (mg/L) average 206 ± 8" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
Biogas Production659mg/L90 %
dry weight measurement
"Biomass production (dry weight, mg/L) max 659 ± 12" · T=30°C, pH(an)=7, substrate=anaerobically digested swine wastewaterAusgeschlossen: kein SI-Wert
25 von 78 angezeigt

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

Eight identical dual-chamber MFCs (1 L each, separated by Nafion 117 PEM) were operated with a carbon brush anode (synthetic piggery wastewater) and carbon cloth cathode (anaerobically digested swine wastewater + Chlorella pyrenoidosa). Cathode electrodes were suspended at 25%, 50%, 75%, or 100% submersion to vary oxygen access. The system was operated at 30°C under continuous light (5000 lux) for 3 batches of 8–10 days each, with 50% substrate replacement every 4 days. Working voltage, current, DO, pH, COD, TN, and NH₃-N were measured every 2 days. Lipid and biomass were quantified at the end of each batch. ANOVA and LSD post-hoc tests were used to assess statistical significance (p < 0.05).

Systemkonfiguration

FeldWert
reactor typeMFC
chamber config2-chamber

Elektrodenspezifikationen

FeldWert
materials["carbon cloth"]

Leistungskennzahlen

FeldWert
citation count42

Betriebsparameter

FeldWert
substrate["wastewater"]

Betriebsbedingungen

1 Lauf extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-d5d5db395f783d63307—anaerobically digested swine wastewater———1000——

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

50 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

60 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

78 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

85 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MFC

Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MFC
System
0,39Volt
Bestes Ergebnis · Spannung
bester von 12
80
Extrahierte Werte
2019
Jahr

Schlagwörter

  • Microbial fuel cell
  • Wastewater
  • Pulp and paper industry
  • Bioenergy
  • Biomass (ecology)
  • Cathode

Zitieren

Jiayin Ling, Yanbin Xu, Chuansheng Lu et al. (2019). Enhancing Stability of Microalgae Biocathode by a Partially Submerged Carbon Cloth Electrode for Bioenergy Production from Wastewater. Energies. https://doi.org/10.3390/en12173229

Zeitschrift
Energies

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen