Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Publikation · MERC
Groundwater Bioremediation through Reductive Dechlorination in a Permeable Bioelectrochemical Reactor
Zusammenfassung
Was die Publikation berichtet, in ihren eigenen Worten.
Zusammenfassung
A new membrane-less bioelectrochemical reactor configuration was developed for contaminated groundwater remediation. The new bioelectrochemical reactor configuration was inspired by the utilisation of a permeable reactive barrier (PBR) configuration with no separation membrane. The corresponding reactive zones were created by using graphite granules and mixed metal oxide (MMO) electrodes to stimulate the reductive and oxidative biological degradation of chlorinated aliphatic hydrocarbons. In the present study, the PBR-like bioelectrochemical reactor has been preliminarily operated with synthetic contaminated groundwater, testing the reductive dechlorination activity on cis-dichloroethylene (cisDCE). Moreover, to assess the effects of competing anions presence for the electron donor (i.e., the cathode), the synthetic wastewater contained sulphate and nitrate anions. In the PBR-like reactor operation, nearly all cisDCE was removed in the initial sampling port, with only VC detected as the observable RD product. During the same biotic test of the PRB reactor, the presence of both the reductive dechlorination and anions reduction was confirmed by the complete nitrate reduction in the cathodic chamber of the PRB reactor. On the contrary, sulphate reduction showed a lower activity; indeed, only 25% of the influent sulphate was removed by the PRB reactor.
KI-Zusammenfassung
78 % KonfidenzA membrane-less bioelectrochemical reactor with graphite granules and a silica-bead separator was tested for reductive dechlorination of cisDCE in synthetic groundwater containing competing electron acceptors (NO₃⁻ and SO₄²⁻). At 100 mA galvanostatic mode and 0.8 d⁻¹ HRT, cisDCE removal reached 96% at the first sampling port, producing VC as the main product. However, competing metabolisms (nitrate reduction 100%, sulphate reduction 25%, methanogenesis 12.4%) consumed most of the supplied current, leaving <0.1% coulombic efficiency for dechlorination. Energy consumption was 4.6 ± 0.9 kWh/m³, substantially higher than an internal counter-electrode configuration (0.6 ± 0.1 kWh/m³) due to high resistance across the non-conductive separator layer.
Zentrale Erkenntnisse
Zielkonflikt Nitrate reduction consumed 17.1% of current and was complete throughout operation, while sulphate reduction increased from 22.6% to higher levels, together accounting for ~40% of coulombic efficiency and dominating over reductive dechlorination at <0.1%.
Was heißt das. Operators must either pre-treat groundwater to remove NO₃⁻ and SO₄²⁻, or accept that dechlorination will be a minor pathway; competing anion reduction is not a side effect but the dominant electron sink.
Zielkonflikt The silica-bead non-conductive separator created a potential drop of ~11 V (most of the total 13 V cell voltage), raising energy consumption 7.7× compared to an internal counter-electrode design operating under similar HRT and feed composition.
Was heißt das. Membrane-less designs with thick non-conductive separators are not economically viable for this application; minimize separator thickness or use ion-exchange membranes to reduce ohmic loss.
Mechanismus Hydrogen was produced at 0.7 ± 0.2 mmol/L in the non-conductive zone (pH 9) and migrated counter-current into the cathode, but was consumed by methanogenesis and dechlorination rather than accumulating, indicating H₂ availability was not rate-limiting.
Was heißt das. H₂ supply is adequate at 100 mA; the bottleneck is not H₂ generation but competition from alternative electron acceptors and high ohmic resistance.
Schwellenwert After 20 days of operation, RD, methanogenesis, and nitrate reduction all decreased simultaneously despite continuous H₂ production, then partially recovered; the cause remained unclear but suggests a transient inhibition or biofilm restructuring unrelated to substrate availability.
Was heißt das. Long-term stability and biofilm dynamics in this configuration are not well understood; extended operation (>30 days) and microbial community profiling are needed before field deployment.
Leistung VC accumulated from 0.9 ± 0.2 to 3.7 ± 0.4 µmol/L at the cathodic effluent (port D) over the test period, indicating incomplete dechlorination to ethene and potential accumulation of a toxic intermediate.
Was heißt das. The system lacks organisms or conditions to reduce VC to ethene; either inoculate with Dehalococcoides or couple with an oxidative stage to mineralize VC.
Ansatzpunkte6
Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.
Hoch No systematic variation of applied current (only 100 mA tested); unclear whether lower current would reduce competing anion reduction or improve dechlorination selectivity.
The paper states 'the rate and extent of microbial dechlorination, nor the competition for produced hydrogen between dechlorination and competing metabolisms' cannot be directly controlled, yet only one current is tested. A current sweep (50–200 mA) would reveal the trade-off between H₂ supply and selectivity.
Versuch. Apply 50, 75, 100, 150, 200 mA galvanostatic; measure cisDCE removal rate, VC accumulation, NO₃⁻ and SO₄²⁻ reduction, and coulombic efficiency for each pathway.
Hoch No investigation of cathode potential control (potentiostatic mode) versus current control (galvanostatic); potentiostatic operation might suppress competing reductions by setting a less negative potential.
The paper uses only galvanostatic mode at 100 mA, which drives the cathode to −640 mV vs. SHE. This potential is sufficiently negative for both dechlorination and anion reduction. Potentiostatic operation at −400 to −500 mV might favor dechlorination over nitrate/sulphate reduction.
Versuch. Operate in potentiostatic mode at −300, −400, −500, −600 mV vs. SHE; measure current draw, dechlorination rate, and coulombic efficiency for each pathway.
Hoch Separator thickness and material not optimized; silica beads (3 cm) create 11 V drop. No test of thinner separators or ion-exchange membranes.
Text states: 'The lower performance of the PRB configuration with respect to the internal counter-electrode configuration was mainly caused by the considerable increase in resistance promoted by the setup of the nonconductive layer.' Energy consumption is 7.7× higher than the counter-electrode design. Reducing separator thickness or using a cation-exchange membrane could dramatically improve economics.
Versuch. Test separator thickness (1, 2, 3, 5 cm silica) and material (Nafion, Selemion, silica) at constant 100 mA; measure cell voltage and energy consumption.
Mittel No measurement of N₂O or NO₂⁻ accumulation during nitrate reduction; incomplete denitrification pathway not characterized.
The paper reports complete NO₃⁻ removal but does not measure N₂O, NO₂⁻, or other denitrification intermediates. Bioelectrochemical systems can accumulate N₂O (a potent greenhouse gas) or NO₂⁻ (toxic) depending on cathode potential and pH.
Versuch. Measure N₂O and NO₂⁻ in headspace and liquid at ports B, D, F using GC-ECD and IC; correlate with cathode potential and pH.
Mittel Inoculum composition and enrichment history not fully disclosed; no 16S rRNA sequencing of the final biofilm after 30 days of operation.
The paper states 'Raw data of the 16S rRNA gene amplicon sequencing of the consortium are available at the DDBJ/ENA/GenBank under the BioProject PRJNA705054' but does not report the final community composition or changes over time. This limits understanding of why methanogenesis and dechlorination declined after day 20.
Versuch. Perform 16S rRNA amplicon sequencing on biofilm samples from ports B and D at days 5, 15, 25, and 35; correlate community shifts with performance changes.
Mittel No test of different C/N or C/S ratios; synthetic groundwater has fixed stoichiometry (400 µmol/L NO₃⁻, 2013 µmol/L SO₄²⁻, negligible TOC ~50 mgC/L).
The paper notes 'a considerably higher concentration of sulphate and nitrate was detected, indicating possible competition for the available reducing power' but does not vary these ratios. Real groundwater may have different anion profiles; the operating window for dechlorination selectivity is unknown.
Versuch. Prepare synthetic groundwater with NO₃⁻ and SO₄²⁻ at 0.5×, 1×, and 2× the baseline concentrations; measure dechlorination rate and coulombic efficiency for each.
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Extrahierte Werte
Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.
n = 62 extrahierte Werte
Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.
23 von 61 extrahierten Zeilen modellierbar
- 17 nicht kanonisiert (kein kanonischer Slug)
- 17 kein SI-Wert
- 3 außerhalb physikalischer Grenzen
- 1 widerspricht anderen Publikationen
| Parameter | Wert | Einheit | Konfidenz | Quelle | Anmerkungen | Modellierbar |
|---|---|---|---|---|---|---|
| Substrate | wastewater | — | 80 % | llm | ||
| Sampling port diameter | 20 | mm | 95 % | design specification | "The PBR reactor was equipped with seven sampling ports, each with a threaded end…" · condition_hint=reactor design parameter | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Particle Size | 3 | mm | 95 % | design specification | "The column was filled with conductive graphite granules with a diameter between …" · condition_hint=reactor design parameter, range 2-4 mm, electrode_material=graphite granules | Modellierbar |
| Sulphate concentration | 2.010 | µmol/L | 95 % | ionic chromatography | "Sulphate 2013 ± 40 µmol/L in groundwater sample (Table 1)" · substrate=groundwater | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Influent Flow Rate | 5,8 | L/d | 95 % | design specification | "the cathode chamber of the bioelectrochemical reactor was continuously fed at a …" · condition_hint=operational parameter | Modellierbar |
| Reactor Height | 1,05 | m | 95 % | design specification | "The bioelectrochemical scale-up reactor consisted of a borosilicate 1.05 m glass…" · condition_hint=reactor design parameter, electrode_material=borosilicate glass | Modellierbar |
| Nitrate concentration | 400 | µmol/L | 95 % | ionic chromatography | "Nitrate 400 ± 21 µmol/L in groundwater sample (Table 1)" · substrate=groundwater | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Nitrate Removal | 100 | % | 95 % | ionic chromatography | "In all investigated conditions, nitrate reduction was complete, and no nitrate w…" · substrate=nitrate, steady_state | Modellierbar |
| Standard Potential | 0,199 | V vs. SHE | 95 % | design specification | "Ag/AgCl reference electrodes (+0.199 vs standard hydrogen electrode, SHE)" · condition_hint=reference electrode specification, electrode_material=Ag/AgCl | Modellierbar |
| Cell Diameter | 10 | cm | 95 % | design specification | "with an internal diameter of 10 cm" · condition_hint=reactor design parameter, electrode_material=borosilicate glass | Modellierbar |
| Reactor Volume Total | 8,24 | L | 95 % | design specification | "and an empty volume of 8.24 L" · condition_hint=reactor design parameter, electrode_material=borosilicate glass | Modellierbar |
| Cathode Potential | -640 | mV vs. SHE | 95 % | potentiometry | "After 30 days of galvanostatic cycles, the cathode potential resulted enough neg…" · substrate=mineral medium, startup | Ausgeschlossen: kein SI-Wert |
| Inoculum Volume | 0,5 | L | 95 % | design specification | "the cathode (between port A and port D) was inoculated with 0.5 L of a TCE-to-et…" · substrate=TCE, startup | Modellierbar |
| Inoculum Volume | 0,2 | L | 95 % | design specification | "and 0.2 L of a cisDCE-to-ethene dechlorinating culture" · substrate=cisDCE, startup | Modellierbar |
| Initial Contaminant Concentration | 0,98 | µmol/L | 95 % | gas-chromatography analysis | "cisDCE 0.98 ± 0.12 µmol/L in groundwater sample (Table 1)" · substrate=cisDCE | Ausgeschlossen: kein SI-Wert |
| Initial Contaminant Concentration | 24,6 | µmol/L | 95 % | gas chromatography with fid | "the cathode chamber of the bioelectrochemical reactor was continuously fed at a …" · pH(an)=7.25, substrate=cisDCE | Ausgeschlossen: kein SI-Wert |
| Chloride Ion Concentration | 800 | µmol/L | 95 % | ionic chromatography | "Chloride 800 ± 16 µmol/L in groundwater sample (Table 1)" · substrate=groundwater | Ausgeschlossen: kein SI-Wert |
| Hydraulic retention time | 6,97 | h | 95 % | tracer step experiment | "The F test curve reported in Figure 1 allowed us to determine the effective hydr…" · condition_hint=tracer experiment with sodium bromide at 5.8 L/d flow rate, 100 mA current | Modellierbar |
| Chamber Volume | 1,7 | L | 95 % | tracer step experiment | "giving an effective volume of 1.7 L" · condition_hint=cathodic compartment of PBR reactor | Modellierbar |
| Anode Potential | 930 | mV vs. SHE | 95 % | potentiometry | "the potential of the anode compartment became more oxidising (930 mV vs. SHE)" · substrate=mineral medium, startup | Ausgeschlossen: kein SI-Wert |
| Initial Contaminant Concentration | 6,8 | µmol/L | 95 % | gas chromatography with fid | "From Figure 5A,C, it is evident that most of the influent cisDCE was removed whi…" · substrate=cisDCE, steady_state | Ausgeschlossen: kein SI-Wert |
| Electrode Diameter | 5 | mm | 95 % | design specification | "graphite rod current collectors (with a diameter of 5 mm, Sigma-Aldrich, Milan, …" · condition_hint=reactor design parameter, electrode_material=graphite rod | Modellierbar |
| Total Organic Carbon | 0,34 | µmol/L | 95 % | gas-chromatography analysis | "VC 0.34 ± 0.10 µmol/L in groundwater sample (Table 1)" · substrate=VC | Ausgeschlossen: kein SI-Wert |
| Particle Size | 2 | mm | 95 % | design specification | "The column was filled with conductive graphite granules with a diameter between …" · condition_hint=reactor design parameter, range 2-4 mm, electrode_material=graphite granules | Modellierbar |
| Total Organic Carbon | 0,59 | µmol/L | 95 % | gas-chromatography analysis | "TCE 0.59 ± 0.3 µmol/L in groundwater sample (Table 1)" · substrate=TCE | Ausgeschlossen: kein SI-Wert |
Methodik
Welches System und wie es betrieben wurde
Methodik
Methodology
A membrane-less bioelectrochemical reactor (1.05 m glass column, 10 cm ID, 8.24 L) was packed with graphite granules (2–4 mm) and separated into cathode and anode compartments by a 3 cm silica-bead layer. Graphite rod current collectors and Ag/AgCl reference electrodes were placed in each compartment. The reactor was operated in galvanostatic mode at 100 mA with synthetic groundwater (24.6 µmol/L cisDCE, 400 µmol/L NO₃⁻, 2013 µmol/L SO₄²⁻) fed at 5.8 L/d (0.8 d⁻¹ HRT). Samples were collected from seven ports along the column and analyzed by GC-FID (chlorinated compounds, methane, ethane), GC-TCD/RGD (H₂), and IC (anions). Coulombic efficiency and energy consumption were calculated from mass balances.
Systemkonfiguration
| Feld | Wert |
|---|---|
| reactor type | BES |
| chamber config | 2-chamber |
Elektrodenspezifikationen
| Feld | Wert |
|---|---|
| materials | ["graphite"] |
Leistungskennzahlen
| Feld | Wert |
|---|---|
| citation count | 5 |
Betriebsparameter
| Feld | Wert |
|---|---|
| substrate | ["wastewater"] |
Betriebsbedingungen
25 Läufe extrahiert| Lauf | T°C | pHAnolyt | pHKatholyt | Substrat | [S]mg/L | HRTh | Modus | R_extΩ | V_appV | Inokulum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-10669e0289480773 | — | — | — | synthetic groundwater with cisDCE | — | — | steady_state | — | — | — |
| v2-1ed329b5c10ea789 | — | — | — | nitrate | — | — | steady_state | — | — | — |
| v2-32ee32e17aac47cf | — | — | — | mineral medium | — | — | startup | — | — | — |
| v2-390c55235dd4f27b | — | — | — | VC | — | — | — | — | — | — |
| v2-49e9a8918dc77531 | — | 9 | — | mineral medium | — | — | — | — | — | — |
| v2-554fdd789771837c | — | — | — | PCE | — | — | — | — | — | — |
| v2-5b5a8dad9c90cfd5 | — | 7.25 | — | sulphate | 150 | — | — | — | — | — |
| v2-6390d7916d380aff | — | — | — | CO2 | — | — | steady_state | — | — | — |
| v2-65986bb55ddd6299 | — | — | — | TCE | — | — | startup | — | — | — |
| v2-6c6deb5c1359d3ba | — | — | — | cisDCE | — | — | startup | — | — | — |
| v2-748f73ef8af08129 | — | 9 | 7 | vc | 92.5 | — | — | — | — | — |
| v2-75ae93c0702a5701 | — | — | — | TCE | — | — | — | — | — | — |
| v2-85cc64b2781286e2 | — | — | — | cisDCE | — | — | steady_state | — | — | — |
| v2-87bb2f3ae94cafa0 | — | 7.25 | — | mineral medium | — | — | — | — | — | — |
| v2-9a42bb053b051b36 | — | — | — | mineral medium | — | — | — | — | — | — |
| v2-9de3516f9ed4ef92 | — | — | — | sulphate | 150 | — | steady_state | — | — | — |
| v2-a037612e4b87bb7f | — | 7 | — | mineral medium | — | — | — | — | — | — |
| v2-ab6bc86d74b0ca9c | — | — | — | nitrate | 35 | — | steady_state | — | — | — |
| v2-b818433889e65dcd | — | — | — | sulphate | — | — | steady_state | — | — | — |
| v2-bb34369d070e672a | — | — | — | synthetic groundwater | — | — | steady_state | — | — | — |
| v2-be86e3a90c71107a | — | — | — | cisDCE | — | — | — | — | — | — |
| v2-c1528e293b02bd57 | — | 7.25 | — | nitrate | 35 | — | — | — | — | — |
| v2-de9bd652caa4674f | — | — | — | groundwater | — | — | — | — | — | — |
| v2-ed16f1597a30bae0 | — | 7.25 | — | cisDCE | — | — | — | — | — | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Extraktionspipeline
Rohextraktionen, Artefakte, Qualitätssignal
Extraktionsqualität
EhrlichkeitssignalBemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.
Parametervollständigkeit
50 %
Anteil der erwarteten Parameter, die extrahiert wurden
Datenvollständigkeit
60 %
Gesamtabdeckung der Extraktion über alle Felder
KI-Konfidenz
78 %
Vom Modell selbst angegebene Konfidenz
Mittlere Parameterkonfidenz
91 %
Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen
vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1
Diagramm-Explorer
Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.
Modell erkunden
Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.
KI-Erkenntnisse
Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.
Ähnliche Publikationen vergleichen
Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.
Quell-PDF
Die Publikation, wie sie erschienen ist.
Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die daraus extrahierten Werte stehen unter „Extrahierte Werte“.
Schlagwörter
- Permeable reactive barrier
- Reductive dechlorination
- Environmental remediation
- Nitrate
- Bioremediation
- Zerovalent iron
Zitieren
Geremia Sassetto, Laura Lorini, Agnese Lai et al. (2024). Groundwater Bioremediation through Reductive Dechlorination in a Permeable Bioelectrochemical Reactor. Catalysts. https://doi.org/10.3390/catal14030208
- Zeitschrift
- Catalysts