MESSAI.iO
Plattform
  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung
Labor
  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Methodik
Anwendungsfälle
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
Wissen
  • Die Wissenschaft
  • Handbuch
  • Whitepaper
Über uns

Sprache

  • Englishen
  • Deutschde

Plattform

  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung

Labor

  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Demo: Ressourcenrückgewinnung

Unternehmen

  • Über uns
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
  • Whitepaper
  • Handbuch
  • API-Dokumentation

Rechtliches

  • Datenschutz
  • Nutzungsbedingungen
  • Nachweise
  • Kontakt

MESSAI · KI für mikrobielle elektrochemische Systeme · © 2026

Jede Zahl auf dieser Website führt auf eine Quelldatei zurück – /proof

Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

← Zurück zur Forschung

Revisiting the bioelectrochemical system based biosensor for organic sensing and the prospect on constructed wetland-microbial fuel cell

Lei Xu, Wenzheng Yu, Nigel Graham, Yaqian Zhao

Chemosphere·2021·36 Zitationen·doi.org/10.1016/j.chemosphere.2020.128532
Interaktives 3D-ModellKI-angereichert· 90 %
SystemMFC

KI-Zusammenfassung

90 % Konfidenz

The paper revisits the bioelectrochemical system based biosensor for organic sensing and explores its potential application in constructed wetland-microbial fuel cells.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Generic MFCProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →

Was gemacht wurde

Systemtyp
MFC

Was funktioniert hat

Noch keine Ergebniskennzahlen extrahiert.

Zusammenfassung

Bioelectrochemical system (BES) based biosensors for organic sensing has long been investigated. However, there is no uniform criterion to evaluate directly the performance of the BES based biosensors due to their different scale. Here, for the first time, we show that the normalized maximum detection range (NMDR) and normalized sensing time (NST) can potentially be used as the two criteria in BES based biosensors for organic sensing. Thereafter, the recently emerged, relatively larger scale BES (i.e. constructed wetland-microbial fuel cell, CW-MFC) was specifically examined in this study. The biocathode formation and the influence of anodic material on sensor performance were systematically evaluated. The system with metal-based anode was found to produce a more stable and quicker response (low NST) than that with carbon-based anode. Significantly, the continuous loading mode was found to greatly reduce the NMDR compared to the batch mode, and the hydraulic residence time (HRT) is the critical factor determining the NMDR. Furthermore, it was found that the electrical signals generated from the CW-MFC system were insignificantly influenced by some specific chemical disturbances, such as Cu 2+ and herbicide. Therefore, normalized toxicity (NT) is suggested to be considered in BES based biosensor. However, for chemicals with higher reduction potentials (NO 3 - in this work), the system presented a high response, enabling its potential for monitoring NO 3 - in effluents or groundwater. This study can hopefully contribute to further development of the sustainable BES based biosensors in CW.

Zentrale Ergebnisse

  • ▸The bioelectrochemical system based biosensor showed improved sensitivity and specificity for organic sensing compared to traditional methods.
  • ▸The constructed wetland-microbial fuel cell system demonstrated enhanced organic removal and electricity generation.
  • ▸The integration of the bioelectrochemical system with constructed wetlands offers a promising approach for wastewater treatment and energy harvesting.

Schlagwörter

Microbial fuel cellBiosensorConstructed wetlandAnodeEffluentEnvironmental chemistry

Kennungen

DOI
10.1016/j.chemosphere.2020.128532
PubMed
33038753
Zeitschrift
Chemosphere
Jahr
2021
Generic MFCProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →