Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MEC

Ammonia Removal by Simultaneous Nitrification and Denitrification in a Single Dual-Chamber Microbial Electrolysis Cell

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 82 %

Zusammenfassung

Ammonia removal from wastewater was successfully achieved by simultaneous nitrification and denitrification (SND) in a double-chamber microbial electrolysis cell (MEC). The MEC operations at different applied voltages (0.7 to 1.5 V) and initial ammonia concentrations (30 to 150 mg/L) were conducted in order to evaluate their effects on MEC performance in batch mode. The maximum nitrification efficiency of 96.8% was obtained in the anode at 1.5 V, followed by 94.11% at 1.0 V and 87.05% at 0.7. At 1.5 V, the initial ammonia concentration considerably affected the nitrification rate, and the highest nitrification rate constant of 0.1601/h was determined from a first-order linear regression at 30 mg/L ammonium nitrogen. The overall total nitrogen removal efficiency was noted to be 85% via the SND in the MEC operated at an initial ammonium concentration of 50 mg/L and an applied cell voltage of 1.5 V. The MEC operation in continuous mode could remove ammonia (50 mg/L) in a series of anode and cathode chambers at the nitrogen removal rate of 170 g-N/m3.d at an HRT of 15. This study suggests that a standalone dual-chamber MEC can efficiently remove ammonia via the SND process without needing additional organic substrate and aeration, which makes this system viable for field applications.

KI-Zusammenfassung

82 % Konfidenz

This dual-chamber MEC study demonstrates simultaneous nitrification and denitrification (SND) for ammonia removal without external organic substrate or aeration. Applied voltage (0.7–1.5 V) controlled dissolved oxygen generation at the anode, enabling nitrification of 30–150 mg NH₄-N/L to nitrate, which was then reduced at the biocathode. Batch mode achieved 96.8% nitrification efficiency and 85% total nitrogen removal at 1.5 V and 50 mg/L inlet ammonia. Continuous operation at 15 h HRT yielded 170 g-N/m³·d removal rate with 81% ammonia removal efficiency, demonstrating potential for field-scale wastewater treatment without supplemental carbon or aeration.

Zentrale Erkenntnisse

  • Schwellenwert Applied voltage directly controls DO generation rate (0.26–0.65 mg/L/h at 0.7–1.5 V), which sets the nitrification rate ceiling; higher voltage accelerates DO buildup but corrosion occurs above 2.0 V.

    Was heißt das. Operators should target 1.5 V as the upper safe limit to maximize DO supply without electrode degradation; below 0.7 V, DO takes >50 h to reach the 2 mg/L nitrification threshold.

  • Zielkonflikt Nitrification rate constant decreases sharply with inlet ammonia loading: 0.160 1/h at 30 mg/L vs. 0.026 1/h at 150 mg/L (6-fold drop), despite constant applied voltage.

    Was heißt das. High-strength ammonia wastewater (>100 mg/L) will require proportionally longer residence times or staged reactors; single-pass treatment becomes kinetically limited.

  • Zielkonflikt Nitrogen diffusion across the cation exchange membrane increases with inlet ammonia loading: 11.2% at 30 mg/L to 14.3% at 150 mg/L, reducing net removal efficiency.

    Was heißt das. Ion-selective membranes or continuous-mode operation (which dilutes concentration gradients) are needed to minimize parasitic diffusion losses, especially at high inlet loads.

  • Mechanismus Denitrifcation is oxygen-sensitive: residual nitrate (4.2 mg/L from 55 mg/L inlet) and nitrite accumulation (<2.5 mg/L) persist because DO diffusion from anode to cathode inhibits the anaerobic reduction pathway.

    Was heißt das. Improve membrane selectivity or add a DO-scavenging step (e.g., L-cysteine dosing) before cathode feed to prevent oxygen cross-over and achieve >90% total nitrogen removal.

  • Zielkonflikt Continuous-mode ammonia removal efficiency is HRT-dependent: 81% at 15 h HRT vs. 97.8% at 25 h HRT, indicating nitrification kinetics are flow-rate limited even at constant applied voltage.

    Was heißt das. Field designs must balance throughput (170 g-N/m³·d at 15 h) against treatment quality; 20–25 h HRT is needed for >95% ammonia removal in continuous mode.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch No measurement of cathode potential or anode potential independently; only cell voltage (0.7–1.5 V) is reported. Anode and cathode potentials vs. SHE are not characterized.

    Section 2.2 states 'applied potential was regulated in the range 0.7 V, 1.0 V, and 1.5 V' but does not specify whether this is cell voltage or individual electrode potentials. Prior work (Zhan et al., cited) uses anodic potential of +800 mV vs. SHE; without electrode potentials, results cannot be compared or reproduced.

    Versuch. Measure anode and cathode potential vs. Ag/AgCl reference electrode at each applied cell voltage; correlate individual potentials to nitrification and denitrification rates.

  • Hoch No N₂O or N₂ quantification; only nitrate and nitrite are tracked. Denitrification pathway (N₂O vs. N₂) is not determined.

    Section 3.4 reports 44.5 mg/L (80.9%) of total nitrogen 'converted to nitrogen gas' but provides no direct measurement of N₂ or N₂O. Residual 4.2 mg NO₃⁻-N/L and <2.5 mg NO₂⁻-N/L account for only ~19%, leaving 1% unaccounted for; N₂O could be a significant byproduct.

    Versuch. Use gas chromatography or membrane inlet mass spectrometry to quantify N₂ and N₂O in cathode headspace during denitrification; determine if N₂O accumulates under high DO or low HRT conditions.

  • Mittel Continuous-mode operation only tested at 15, 20, and 25 h HRT; no intermediate values or shorter HRTs (<15 h) explored.

    Figure 7A shows ammonia removal drops to 81% at 15 h HRT but the paper does not test whether 10–12 h HRT is feasible or where the kinetic limit lies. Practical field designs need to know the minimum HRT for acceptable removal (e.g., 90%).

    Versuch. Operate continuous mode at HRT = 10, 12, 15, 18, 20, 25 h; plot ammonia removal efficiency and nitrogen removal rate vs. HRT to identify the optimal operating window.

  • Mittel No variation of applied voltage in continuous mode; only 1.5 V is tested. Trade-off between voltage, DO generation, and energy cost is not explored.

    Batch experiments show 1.0 V achieves 94.11% nitrification efficiency vs. 96.8% at 1.5 V (only 2.7% gain), but energy cost and electrode wear are not compared. Section 3.1 notes corrosion at 2.0 V but does not quantify electrode lifetime or energy consumption.

    Versuch. Operate continuous mode at 0.7, 1.0, 1.5 V; measure power consumption (W), electrode mass loss, and ammonia removal rate to calculate energy cost per kg N removed and electrode durability.

  • Mittel Cation exchange membrane (CEM) is used instead of proton exchange membrane (PEM), but no comparison of nitrogen diffusion or ion selectivity between the two.

    Section 2.1 states CEM was chosen for 'high rigidity, versatility, and low-cost' but Section 3.3 reports 14.3% nitrogen diffusion loss at 150 mg/L inlet. No data on whether PEM would reduce this loss or whether a more selective membrane (e.g., anion exchange) would improve denitrification.

    Versuch. Compare CEM vs. PEM vs. anion exchange membrane (AEM) in parallel batch experiments; measure nitrogen diffusion and denitrification efficiency at 50 and 150 mg NH₄-N/L inlet.

  • Mittel Cathode biofilm composition and denitrifier enrichment are not characterized; no molecular analysis (16S rRNA, metagenomics) or enzyme assays (nitrate reductase, nitrite reductase).

    Section 2.1 states cathode was 'inoculated with sewage sludge' and 'operated for one month to develop nitrifiers at the anode and denitrifiers at the cathode' but no confirmation that autotrophic denitrifiers (as claimed in Introduction) actually colonized the cathode. Heterotrophic denitrifiers could be responsible, which would require organic carbon.

    Versuch. Perform 16S rRNA gene sequencing on anode and cathode biofilms at steady state; quantify autotrophic vs. heterotrophic denitrifier abundance; measure nitrate reductase and nitrite reductase activity.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 64 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

24 von 62 extrahierten Zeilen modellierbar

  • 10 nicht kanonisiert (kein kanonischer Slug)
  • 28 kein SI-Wert
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Substratewastewater—80 %
llm
Coulombic efficiency96,8%80 %
llm
Dissolved Oxygen3mg/L95 %
do probe measurement
"the DO concentration increased in all the conditions and finally reached to 2.6, …" · T=35°C, steady_stateModellierbar
Dissolved Oxygen2,6mg/L95 %
do probe measurement
"the DO concentration increased in all the conditions and finally reached to 2.6, …" · T=35°C, steady_stateModellierbar
Nitrogen Removal170g-N/m³.d95 %
extrahiert
"The MEC operation in continuous mode could remove ammonia (50 mg/L) in a series …" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Nitrate Consumption Rate0,161/h95 %
first-order linear regression
"the highest nitrification rate constant of 0.1601/h was determined from a first-or…" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Dissolved Oxygen3,1mg/L95 %
do probe measurement
"the DO concentration increased in all the conditions and finally reached to 2.6, …" · T=35°C, steady_stateModellierbar
Ammonia Removal Efficiency87,1%95 %
extrahiert
"and 87.05% at 0.7" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Ammonia Removal Efficiency96,8%95 %
extrahiert
"The maximum nitrification efficiency of 96.8% was obtained in the anode at 1.5 V" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Total Nitrogen Removal85%95 %
extrahiert
"The overall total nitrogen removal efficiency was noted to be 85% via the SND in …" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Ammonia Removal Efficiency94,1%95 %
extrahiert
"followed by 94.11% at 1.0 V" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Nitrate Consumption Rate0,072L/h90 %
first-order kinetics
"The calculated constants from using 30, 50, and 150 mg/L of ammonium nitrogen in…" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Ammonium-N Removed93,3%90 %
extrahiert
"By the end of the operation (50 h), and 93.3% conversion of ammonium nitrogen to…" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Nitrate nitrogen effluent concentration4,2mg/L90 %
extrahiert
"By the end of the operation (170 h), the 55 mg/L of nitrate-nitrogen was decreas…" · T=35°C, substrate=nitrate nitrogen, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Nitrate nitrogen concentration52,1mg/L90 %
extrahiert
"The initial 55.8 mg/L of ammonium nitrogen was decreased to 0.7 mg/L, with a sim…" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Ammonium Ion Concentration13,5mg/L90 %
extrahiert
"At 20 h, with 0.7 V, 1.0 V, and 1.5 V, the effluent ammonium nitrogen concentrati…" · T=35°C, substrate=ammonium nitrogen, transientModellierbar
Ammonium Ion Concentration10,9mg/L90 %
extrahiert
"At 20 h, with 0.7 V, 1.0 V, and 1.5 V, the effluent ammonium nitrogen concentrati…" · T=35°C, substrate=ammonium nitrogen, transientModellierbar
Nitrogen Removal44,5mg/L90 %
extrahiert
"Overall, 44.5 mg/L or 80.9% of total nitrogen was converted to nitrogen gas" · T=35°C, substrate=nitrate nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Nitrogen Removal149g-N/m³.d90 %
extrahiert
"compared to what was obtained for HRT 20 (149 g-N/m3.d)" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Total Nitrogen Removal80,9%90 %
extrahiert
"Overall, 44.5 mg/L or 80.9% of total nitrogen was converted to nitrogen gas" · T=35°C, substrate=nitrate nitrogen, steady_stateModellierbar
Ammonium-N Removed81%90 %
extrahiert
"the ammonia-nitrogen was less for the first few hours (~50 h) and then became sta…" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Nitrate Consumption Rate0,055L/h90 %
first-order kinetics linear regression
"the computed constants with the application of 0.7 V, 1.0V, and 1.5 V, are noted…" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Nitrate Consumption Rate0,044L/h90 %
first-order kinetics linear regression
"the computed constants with the application of 0.7 V, 1.0V, and 1.5 V, are noted…" · T=35°C, substrate=ammonium nitrogen, steady_stateAusgeschlossen: kein SI-Wert
Ammonium-N Removed95%90 %
extrahiert
"the ammonia-nitrogen was less for the first few hours (~50 h) and then became sta…" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
Ammonium Ion Concentration7,2mg/L90 %
extrahiert
"the total removal was observed at 50 h and 140 h, with an effluent concentration …" · T=35°C, substrate=ammonium nitrogen, steady_stateModellierbar
25 von 63 angezeigt

Literatur-Priors

Verteilung

Im Vergleich zur Literatur

Der in der Publikation berichtete Wert (▼) ist auf der Literaturverteilung aus MESS-Parameters eingezeichnet. Werte außerhalb des Bands werden als Ausreißer gekennzeichnet.

Coulombic efficiency96,8Prozent

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

The study used a dual-chamber MEC (420 mL total volume) with carbon fiber brush electrodes separated by a cation exchange membrane. Anode and cathode were inoculated with sewage sludge and acclimated for one month. Batch experiments (0.7–1.5 V, 30–150 mg NH₄-N/L inlet, 100 h cycles) evaluated nitrification kinetics and voltage effects. Continuous-mode tests (15–25 h HRT, 50 mg NH₄-N/L inlet, 200 h duration) assessed steady-state performance. Nitrogen species (NH₄-N, NO₃-N, NO₂-N, total N) were measured by spectrophotometry; dissolved oxygen by probe; pH by electrode. First-order kinetics were fitted to batch ammonia removal data.

Systemkonfiguration

FeldWert
reactor typeMEC
chamber config2-chamber

Leistungskennzahlen

FeldWert
coulombic efficiency96.8
citation count11

Betriebsparameter

FeldWert
substrate["wastewater"]

Betriebsbedingungen

18 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-07462404aff9255235—————steady_state—1.5—
v2-0dc40916a0859e7935——ammonium nitrogen50—transient—1.5—
v2-0f2b218262dae34035——nitrate nitrogen55—steady_state—1.5—
v2-1fa4fc0f1547fe5f35——ammonium nitrogen50—steady_state—1.5—
v2-29a9ea4b2ddb64c835—————steady_state—1—
v2-3392b9659210e88035—————steady_state—0.7—
v2-3e033c4f57a586c335——ammonium nitrogen50—transient—1—
v2-50ab3fec0dd5132635——ammonium nitrogen55—steady_state—1.5—
v2-51f7994682633ef635——ammonium nitrogen150—startup—1.5—
v2-835d3a7ea6123e8735——ammonium nitrogen150—steady_state—1.5—
v2-8575e24ce7d608e335——ammonium nitrogen50—transient—0.7—
v2-85af779d10df427035——ammonium nitrogen30—steady_state—1.5—
v2-879e8ea811691c1235———————1.5—
v2-a3410e2ba51bceaf35——ammonium nitrogen50—steady_state—0.7—
v2-b5b0df16ec94a45735——nitrate nitrogen55———1.5—
v2-b99fd1ee41d53df335———————0.7—
v2-bf7be62cb730fea135——ammonium nitrogen50—steady_state—1—
v2-eeab7128b08e1aa535———————1—

Ergebnisse

Was gemessen wurde und was funktioniert hat

Kernaussagen

Coulombic efficiency

Elektrochemie

96.8Prozent

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

50 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

70 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

82 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

88 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MEC

Repräsentatives Modell: MEC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MEC
System
96,8Prozent
Bestes Ergebnis · Coulomb-Effizienz
bester von 2
64
Extrahierte Werte
2022
Jahr

In diesem Datensatz

Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.

Parameter · 1

Schlagwörter

  • Nitrification
  • Ammonia
  • Electrolysis
  • Anode
  • Ammonium
  • Aeration

Zitieren

Sanath Kondaveeti, Dae-Hyeon Choi, Md Tabish Noori et al. (2022). Ammonia Removal by Simultaneous Nitrification and Denitrification in a Single Dual-Chamber Microbial Electrolysis Cell. Energies. https://doi.org/10.3390/en15239171

Zeitschrift
Energies

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen