Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Publikation · MBES
Microbial Fuel Cell as a Bioelectrochemical Sensor of Nitrite Ions
Zusammenfassung
Was die Publikation berichtet, in ihren eigenen Worten.
Zusammenfassung
The deteriorating environmental quality requires a rapid in situ real-time monitoring of toxic compounds in environment including water and wastewater. One of the most toxic nitrogen-containing ions is nitrite ion, therefore, it is particularly important to ensure that nitrite ions are completely absent in surface and ground waters as well as in wastewater or, at least, their concentration does not exceed permissible levels. However, no selective ion electrode, which would enable continuous measurement of nitrite ion concentration in wastewater by bioelectrochemical sensor, is available. Microbial fuel cell (MFC)-based biosensor offers a sustainable low-cost alternative to the monitoring by periodic sampling for laboratory testing. It has been determined, that at low (0.01–0.1 mg·L⁻¹) and moderate (1.0–10 mg·L⁻¹) concentration of nitrite ions in anolyte-model wastewater, the voltage drop in MFC linearly depends on the logarithm of nitrite ion concentration of proving the potential of the application of MFC-based biosensor for the quantitative monitoring of nitrite ion concentration in wastewater and other surface water. Higher concentrations (100–1000 mg·L⁻¹) of nitrite ions in anolyte-model wastewater could not be accurately quantified due to a significant drop in MFC voltage. In this case MFC can potentially serve as a bioelectrochemical early warning device for extremely high nitrite pollution.
KI-Zusammenfassung
78 % KonfidenzThis paper demonstrates a dual-chamber MFC with Shewanella putrefaciens as a biosensor for nitrite detection in wastewater. The MFC voltage drop correlates linearly with the logarithm of NO2− concentration in the range 0.01–10 mg·L⁻¹ (covering regulatory limits worldwide), with a limit of detection of ~0.0028 mg·L⁻¹. At higher concentrations (100–1000 mg·L⁻¹), voltage recovery fails due to bacterial toxicity, making the system useful as an early-warning device. Partial denitrification (25–30% removal at low concentrations) occurs at the bioanode via electron competition between exoelectrogens and NO2− reduction.
Zentrale Erkenntnisse
Schwellenwert MFC voltage drop follows a linear relationship with log(NO2−) concentration only in the 0.01–10 mg·L⁻¹ range; above 100 mg·L⁻¹ the slope flattens and recovery fails, restricting quantitative measurement to regulatory-relevant concentrations.
Was heißt das. Operators should use this MFC design only for monitoring in the 0.01–10 mg·L⁻¹ window; above 100 mg·L⁻¹ switch to a threshold-based early-warning mode rather than attempting quantification.
Zielkonflikt Nitrite ion retention in the anode half-cell (4–5 samples, ~160–200 mL residence) causes rapid voltage drop on exposure but slow recovery (30–60 min for low/moderate concentrations), decoupling the sensor response timescale from the actual inlet concentration change.
Was heißt das. Design sampling protocols with a 60+ minute settling time after switching feeds to avoid false negatives; consider reducing anolyte flow rate (HRT extension) to improve detection sensitivity at the cost of response time.
Mechanismus Partial denitrification removes 25–30% of NO2− at low inlet concentrations (0.01–0.1 mg·L⁻¹) but only 0.24–1.49% at high concentrations (100–1000 mg·L⁻¹), indicating electron availability becomes limiting under high nitrite stress.
Was heißt das. At high nitrite loads, the MFC does not function as a denitrification reactor; if N2O or NO3− accumulation is a concern, operate in the low-concentration regime or increase anode surface area to boost electron supply.
Mechanismus MFC voltage recovery failure at ≥100 mg·L⁻¹ NO2− is attributed to bacterial toxicity and partial biofilm loss, not substrate depletion, since acetate remains available and voltage does not recover even after 2 h of nitrite-free feed.
Was heißt das. Do not attempt to recover the system by flushing; instead, plan for biofilm re-inoculation or use redundant MFC units if high-concentration excursions are expected.
Ansatzpunkte6
Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.
Hoch No evaluation of cathode potential, anode potential, or electrochemical impedance across the NO2− concentration range; unclear whether voltage drop is due to anode overpotential increase, cathode limitation, or ohmic resistance change.
The paper measures only terminal voltage and current; Section 3.2 attributes voltage drop to 'anode electrochemical potential increase' but provides no potentiostat data to confirm this or rule out cathode oxygen limitation.
Versuch. Perform cyclic voltammetry or potentiostatic control at fixed anode/cathode potentials across 0.01–1000 mg·L⁻¹ NO2− to isolate the source of voltage loss.
Hoch No measurement of N2O, NO, or other nitrogen species in the gas phase or liquid phase; denitrification pathway (NO2− → N2 vs. NO2− → NO → N2O → N2) is not characterized.
Section 3.3 proposes equation (4) for reduction to N2, but only total NO2− removal is measured (Table 2); no gas chromatography or ion chromatography data on product distribution.
Versuch. Collect anode headspace gas and analyze by GC-MS for N2, N2O, NO; measure outlet anolyte for NO3−, NO2−, and NH4+ to close the nitrogen balance.
Mittel No variation of anolyte hydraulic retention time (HRT) or flow rate; paper mentions HRT extension as a potential improvement but does not test it.
Section 3.2 states: 'the application of a MFC for the more accurate measurement of the higher concentration of nitrite ions could be achieved by reducing the flow rate of the anolyte through the anodic half-cell, which is essentially in line with the extension of the analyzed anolyte-wastewater hydraulic retention time' but no experiments are shown.
Versuch. Test anolyte flow rates of 6, 12, 24 mL·min⁻¹ (HRT ~5.3, 2.7, 1.3 min) across 0.01–100 mg·L⁻¹ NO2− to map the trade-off between sensitivity and response time.
Mittel No investigation of catholyte pH, dissolved oxygen concentration, or aeration rate effects on voltage response; all experiments use fixed aeration (~200 mL·min⁻¹ air) and no pH control.
Section 2.3 specifies constant aeration and nitrogen flow but does not vary these; Figure 2 shows DO reaches 7.2 mg·L⁻¹ in catholyte but no sensitivity analysis is provided.
Versuch. Vary catholyte DO (5–8 mg·L⁻¹), pH (6–8), and aeration rate (100–300 mL·min⁻¹) to determine if cathode oxygen availability limits voltage recovery at high NO2− concentrations.
Mittel No testing of multi-stage MFCs in series; paper mentions this as a potential solution for high-concentration measurement but provides no proof-of-concept.
Section 3.2 suggests: 'by using multi-stage MFCs connected in series' but no experimental data or design is provided.
Versuch. Build a 2–3 stage MFC cascade and test voltage response to 100–1000 mg·L⁻¹ NO2− to assess whether serial connection extends the linear range.
Mittel No long-term stability or biofilm viability testing; all experiments are single-pass batch tests with fresh inoculum; unclear if the sensor can be reused or how many cycles it tolerates.
Section 3.2 describes one-time exposure to each NO2− concentration with recovery between tests, but does not report cumulative damage, biofilm regrowth kinetics, or sensor lifetime.
Versuch. Perform 10–20 repeated cycles of 0.01–10 mg·L⁻¹ NO2− exposure and recovery to quantify biofilm resilience and sensor drift over time.
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Extrahierte Werte
Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.
n = 19 extrahierte Werte
Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.
0 von 18 extrahierten Zeilen modellierbar
- 18 nicht kanonisiert (kein kanonischer Slug)
| Parameter | Wert | Einheit | Konfidenz | Quelle | Anmerkungen | Modellierbar |
|---|---|---|---|---|---|---|
| Substrate | wastewater | — | 80 % | llm | ||
| Nitrite removal | 36,1 | % | 85 % | molecular absorption spectrometry (540 nm) at mfc anode inlet vs outlet (table 2) | "Decrease in Nitrite Ion Concentration ... 0.01 -> 36.1%" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Nitrite removal | 0,24 | % | 85 % | molecular absorption spectrometry (table 2) | "1000.0 -> 0.24%" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Maximum average current | 33 | microA | 85 % | average current during 15-min load at each resistance (fig 4b) | "it reached a maximum average current of ~33 uA at an external resistance of 1 ko…" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Maximum dissolved oxygen catholyte | 7,2 | mg/L | 85 % | luminescent/optical do probe (hach hq40d) | "The maximum concentration of DO (7.2 mg/L) in the catholyte was achieved after a…" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Nitrite removal | 6,31 | % | 85 % | molecular absorption spectrometry (table 2) | "10.0 -> 6.31%" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Open circuit voltage stable | 250 | mV | 85 % | ocv vs time (potentiostat sp-150) | "stabilized at ~250 mV after 13-15 h" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Maximum open circuit voltage | 275 | mV | 85 % | ocv vs time (potentiostat sp-150) | "When the MFC open circuit voltage reached a maximum value of ~275 mV, it dropped…" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Nitrite removal | 9,74 | % | 85 % | molecular absorption spectrometry (table 2) | "1.0 -> 9.74%" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Nitrite removal | 1,49 | % | 85 % | molecular absorption spectrometry (table 2) | "100.0 -> 1.49%" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Nitrite removal | 22,8 | % | 85 % | molecular absorption spectrometry (table 2) | "0.1 -> 22.8%" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Limit of detection | 0,0028 | mg/L | 80 % | lod = 3.3 sigma/m from low-range (0.01-10 mg/l) log-linear calibration | "The calculated LOD for nitrite ion concentration is ~0.0028 mg/L" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Voltage drop | 89 | % | 75 % | mfc voltage drop (fig 6) | "the MFC voltage drop values are very high (reaching 89% and 95%, respectively) […" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Voltage drop | 95 | % | 75 % | mfc voltage drop (fig 6) | "reaching 89% and 95%, respectively; ~95% at 1000 mg/L" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Operating voltage | 30 | mV | 70 % | voltage across 1 kohm load | "the passive resistance of 1 kohm, at which MFC generated the highest average cur…" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Voltage drop | 47 | % | 60 % | mfc voltage drop (fig 6) | "~47% at 0.1 mg/L (read from plot)" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Voltage drop | 64 | % | 60 % | mfc voltage drop (fig 6) | "~64% at 1.0 mg/L (read from plot)" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Voltage drop | 27 | % | 60 % | mfc voltage drop after feeding nitrite-contaminated anolyte (fig 6) | "Figure 6 voltage drop vs NO2- concentration; ~27% at 0.01 mg/L (read from plot).…" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Voltage drop | 78 | % | 60 % | mfc voltage drop (fig 6) | "~78% at 10 mg/L (read from plot)" · T=22°C, substrate=sodium acetate (CH3COONa.3H2O), batch | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
Methodik
Welches System und wie es betrieben wurde
Methodik
Methodology
A dual-chamber MFC with graphite felt electrodes (7×7×0.65 cm) separated by a Nafion PEM was inoculated with Shewanella putrefaciens and operated in batch mode with continuous anolyte circulation (12 mL·min⁻¹, anaerobic) and aerated catholyte circulation (30 mL·min⁻¹, ~200 mL·min⁻¹ air). Voltage was measured across a 1 kΩ load (optimized from 32 kΩ to 15 Ω sweep). Nitrite-contaminated anolyte (0.01–1000 mg·L⁻¹ NO2−) was fed for 80 mL (residence time ~6.7 min), then switched back to nitrite-free anolyte; voltage recovery and outlet NO2− concentration were monitored. All experiments were replicated ≥3 times with mean and standard deviation reported.
Systemkonfiguration
| Feld | Wert |
|---|---|
| reactor type | MFC |
| chamber config | 2-chamber |
Leistungskennzahlen
| Feld | Wert |
|---|---|
| citation count | 14 |
Betriebsparameter
| Feld | Wert |
|---|---|
| substrate | ["wastewater"] |
Betriebsbedingungen
9 Läufe extrahiert| Lauf | T°C | pHAnolyt | pHKatholyt | Substrat | [S]mg/L | HRTh | Modus | R_extΩ | V_appV | Inokulum |
|---|---|---|---|---|---|---|---|---|---|---|
| cma:baseline_1kohm | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:inoculation_OCV | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | — | — | Shewanella putrefaciens NCTC 10695 (DSM 1818), pure culture grown in LB broth |
| cma:load_selection | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | — | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:nitrite_0.01 | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:nitrite_0.1 | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:nitrite_1.0 | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:nitrite_10 | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:nitrite_100 | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
| cma:nitrite_1000 | 22 | — | — | sodium acetate (CH3COONa.3H2O) | 3 | — | batch | 1000 | — | Shewanella putrefaciens NCTC 10695, pure culture |
Extraktionspipeline
Rohextraktionen, Artefakte, Qualitätssignal
Extraktionsqualität
EhrlichkeitssignalBemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.
Parametervollständigkeit
38 %
Anteil der erwarteten Parameter, die extrahiert wurden
Datenvollständigkeit
60 %
Gesamtabdeckung der Extraktion über alle Felder
KI-Konfidenz
78 %
Vom Modell selbst angegebene Konfidenz
Mittlere Parameterkonfidenz
77 %
Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen
vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1
Diagramm-Explorer
Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.
Modell erkunden
Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.
KI-Erkenntnisse
Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.
Ähnliche Publikationen vergleichen
Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.
Quell-PDF
Die Publikation, wie sie erschienen ist.
Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die daraus extrahierten Werte stehen unter „Extrahierte Werte“.
Schlagwörter
- Nitrite
- Wastewater
- Microbial fuel cell
- Environmental chemistry
- Biosensor
- Sewage treatment
Zitieren
Arnas Klevinskas, Kristina Kantminienė, Nerita Žmuidzinavičienė et al. (2021). Microbial Fuel Cell as a Bioelectrochemical Sensor of Nitrite Ions. Processes. https://doi.org/10.3390/pr9081330
- Zeitschrift
- Processes