Possibilities of using a corona electric discharge generator in the processes of water and surface sterilization

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

KI-angereichert· 90 %

Zusammenfassung

The work is devoted to the use of an electric discharge in the geometry of a point electrode – a plane surface for the sterilization of water and surfaces contaminated with bacteria. The relationship between the concentrations of oxidizing impurities and active species generated in an electric discharge is discussed. It is shown that if the concentration of active species is too high, they will interact predominantly with each other and die without producing any effect. Using the example of cyanide decomposition, it is shown that the highest decomposition efficiency is achieved at the maximum voltage on the discharge electrode and the minimum electric discharge current. Therefore, a corona electric discharge was chosen for work. In a corona electric discharge generator in air in the presence of water vapor, an ozone-hydroxyl mixture is formed, in which the lifetime of hydroxyl radicals is ~ 1 sec. This makes it possible to extract hydroxyl radicals from the discharge cavity and ensure their contact with the water flow. After treatment in the generator, the water is purified from impurities within the limits allowed by the release of active species concentration, saturated with ozone and air oxygen to the solubility limit at a given water temperature, and becomes oxygenated. For the experiments, a prototype of the corona electric discharge generator was made. The voltage applied to the discharge electrodes was minus 11 kV, and the total discharge current was 1.7 mA. The choice of parameters of the electrical circuit that forms and maintains the corona discharge is analyzed. The bactericidal effect of the generator was determined for a liquid contaminated with bacteria and for a contaminated surface. The bactericidal effect of the liquid was evaluated after passing it through the reactor of the corona discharge generator. Water flow 150 L/h. The energy costs for reducing CFU (Coli Forming Units) by 10 times for an aqueous solution containing the bacteria Escherichia coli, Enterobacter cloacae, Pseudomonas aeruginosa, Enterococcus faecalis at a concentration of 10–103 CFU per 100 ml of solution are 59±6 J/100 ml of solution for each type of bacteria. Surface sterilization was carried out by spraying the contaminated surface with water after its treatment in the generator reactor. The area of contaminated samples was 25 cm². To reduce CFU by 10 times on a surface contaminated with gram-negative bacteria Escherichia coli and gram-positive bacteria Staphylococcus aureus at a concentration of 104 CFU/cm², an energy of 100±11 J/cm² was expended. High energy costs for surface sterilization are associated with the inefficient use of oxygenated water in this experiment, since the water was drained from the surface without losing its activity. Water retains noticeable activity up to 4 hours. Thus, the water produced by the generator can disinfect large surfaces, which will significantly reduce energy costs. For comparison, the solution was disinfected with UV radiation by irradiation in a Petri dish. A DKB-9 low-pressure mercury lamp emitting 253.7 nm photons was used. The energy spent on reducing CFU by 10 times was 1.6±0.2 and 0.7±0.1 J/cm² for Staphylococcus aureus and Escherichia coli, respectively. The advantage of decontamination with oxygenated water is that contaminated objects can be washed from all sides, which is not possible using lamp radiation. The results obtained make it possible to calculate the modes of sterilization of a liquid and a contaminated surface using a corona discharge generator and oxygenated water depending on the concentration of microorganisms. Oxygenated water is an environmentally friendly disinfectant, since the active species formed during the generator treatment break down into water and oxygen over time.

KI-Zusammenfassung

90 % Konfidenz

MES research in electrode, bacteria. The work is devoted to the use of an electric discharge in the geometry of a point electrode – a pla...

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 2 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

0 von 2 extrahierten Zeilen modellierbar

  • 1 nicht kanonisiert (kein kanonischer Slug)
  • 1 kein SI-Wert
ParameterWertEinheitKonfidenzQuelleModellierbar
Dominant organismPseudomonas—80 %
extrahiert
Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Volume0,1mL60 %
extrahiert
Ausgeschlossen: kein SI-Wert

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

The researchers used a corona electric discharge generator to investigate the sterilization of water and surfaces contaminated with bacteria, focusing on the relationship between oxidizing impurities and active species generated in the electric discharge.

Elektrodenspezifikationen

FeldWert
anode area25

Biologische Parameter

FeldWert
dominant species["Pseudomonas","Escherichia","Enterobacter"]

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

38 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

40 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

90 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

70 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die daraus extrahierten Werte stehen unter „Extrahierte Werte“.

2
Extrahierte Werte
2024
Jahr

In diesem Datensatz

Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.

Schlagwörter

  • Sterilization (economics)
  • Corona discharge
  • Electric discharge
  • Corona (planetary geology)

Zitieren

E.D. Kuzina, I. P. Ivanova, I. Piskarev (2024). Possibilities of using a corona electric discharge generator in the processes of water and surface sterilization. Science Intensive Technologies. https://doi.org/10.18127/j19998465-202404-05