Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MES

Low electric current in a bioelectrochemical system facilitates ethanol production from CO using CO-enriched mixed culture

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 95 %

Zusammenfassung

Fossil resources must be replaced by renewable resources in production systems to mitigate green-house gas emissions and combat climate change. Electro-fermentation utilizes a bioelectrochemical system (BES) to valorize industrial and municipal waste. Current electro-fermentation research is mainly focused on microbial electrosynthesis using CO 2 for producing commodity chemicals and replacing petroleum-based infrastructures. However, slow production rates and low titers of metabolites during CO 2 -based microbial electrosynthesis impede its implementation to the real application in the near future. On the other hand, CO is a highly reactive gas and an abundant feedstock discharged from fossil fuel-based industry. Here, we investigated CO and CO 2 electro-fermentation, using a CO-enriched culture. Fresh cow fecal waste was enriched under an atmosphere of 50% CO and 20% CO 2 in N 2 using serial cultivation. The CO-enriched culture was dominated by Clostridium autoethanogenum (≥89%) and showed electro-activity in a BES reactor with CO 2 sparging. When 50% CO was included in the 20% CO 2 gas with 10 mA applied current, acetate and ethanol were produced up to 12.9 ± 2.7 mM and 2.7 ± 1.1 mM, respectively. The coulombic efficiency was estimated to 148% ± 8% without an electron mediator. At 25 mA, the culture showed faster initial growth and acetate production but no ethanol production, and only at 86% ± 4% coulombic efficiency. The maximum optical density (OD) of 10 mA and 25 mA reactors were 0.29 ± 0.07 and 0.41 ± 0.03, respectively, whereas it was 0.77 ± 0.19 without electric current. These results show that CO electro-fermentation at low current can be an alternative way of valorizing industrial waste gas using a bioelectrochemical system.

KI-Zusammenfassung

95 % Konfidenz

BES research focusing on bacteria, power, substrate. Fossil resources must be replaced by renewable resources in production systems to mitigate green-house gas emissions and combat climate change. Electro-fermentation utilizes a bioelectrochemic...

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 42 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

8 von 40 extrahierten Zeilen modellierbar

  • 5 nicht kanonisiert (kein kanonischer Slug)
  • 27 kein SI-Wert
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Substrateacetate,ethanol—80 %
llm
Coulombic efficiency8%80 %
llm
Acetic Acid Concentration5,8mM95 %
hplc with refractive index detector
"While no acetate production was observed in the abiotic experiment, formate was …" · T=37°C, pH(an)=5, substrate=CO and CO2Ausgeschlossen: kein SI-Wert
Relative Abundance89,1%95 %
16s rrna sequencing (v1-v2 primer set)
"The majority of the bacterial community (≥89%) was found to consist of Clostridi…" · T=37°C, pH(an)=5, substrate=CO and CO2Modellierbar
Acetic Acid Concentration11,3mM95 %
hplc with refractive index detector
"At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=5.9, substrate=CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration12,9mM95 %
hplc with refractive index detector
"At the end of the experiment, 12.9 ± 2.7 mM acetate and 2.7 ± 1.1 mM ethanol wer…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Biomass Concentration0,3—95 %
spectrophotometry at 600 nm
"When 10 mA of electric current was applied, the maximum OD was lower (0.30 ± 0.0…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration6,8mM95 %
hplc with refractive index detector
"At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=6.2, substrate=CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration3mM95 %
hplc with refractive index detector
"While no acetate production was observed in the abiotic experiment, formate was …" · T=37°C, pH(an)=5, substrate=CO and CO2Ausgeschlossen: kein SI-Wert
Acetic Acid Concentration16,9mM95 %
hplc with refractive index detector
"When no electric current was applied, the maximum OD, 0.78 ± 0.19, was achieved …" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Biomass Concentration0,77—95 %
spectrophotometry at 600 nm
"The maximum optical density (OD) of 10 mA and 25 mA reactors were 0.29 ± 0.07 an…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Biomass Concentration0,42—95 %
spectrophotometry at 600 nm
"The maximum OD reached 0.42 ± 0.04 on day 2, and 15.3 ± 3.0 mM of acetate was de…" · T=37°C, pH(an)=5, substrate=CO and CO2, startupAusgeschlossen: kein SI-Wert
Acetic Acid Concentration15,3mM95 %
hplc with refractive index detector
"The maximum OD reached 0.42 ± 0.04 on day 2, and 15.3 ± 3.0 mM of acetate was de…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration0,6g/L95 %
hplc with refractive index detector
"Acetate and ethanol titers (g/L) Ac 0.60 ± 0.03 Eth 0.12 ± 0.05" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateModellierbar
Specific Growth Rate0,044h⁻¹95 %
spectrophotometry at 600 nm
"The cell growth rate in the 25 mA reactor was faster (μ = 0.044 ± 0.001 h−1) tha…" · T=37°C, pH(an)=6.2, substrate=CO2, startupModellierbar
Specific Growth Rate0,011h⁻¹95 %
spectrophotometry at 600 nm
"The cell growth rate in the 25 mA reactor was faster (μ = 0.044 ± 0.001 h−1) tha…" · T=37°C, pH(an)=5.9, substrate=CO2, startupModellierbar
Relative Abundance94,3%95 %
16s rrna sequencing (v3-v4 primer set)
"The majority of the bacterial community (≥89%) was found to consist of Clostridi…" · T=37°C, pH(an)=5, substrate=CO and CO2Modellierbar
Relative Abundance4,03%95 %
16s rrna sequencing (v3-v4 primer set)
"Lacticaseobacillus chiayiensis (4% with primers V3–V4)" · T=37°C, pH(an)=5, substrate=CO and CO2Modellierbar
Relative Abundance7,49%95 %
16s rrna sequencing (v1-v2 primer set)
"The second most frequent bacterial species of the enriched community was identif…" · T=37°C, pH(an)=5, substrate=CO and CO2Modellierbar
Acetic Acid Concentration1,2mM95 %
hplc with refractive index detector
"At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=6.2, substrate=CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration0,72g/L95 %
hplc with refractive index detector
"Acetate and ethanol titers (g/L) ... Ac 0.72 ± 0.14" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateModellierbar
Acetic Acid Concentration2,7mM95 %
hplc with refractive index detector
"At the end of the experiment, 12.9 ± 2.7 mM acetate and 2.7 ± 1.1 mM ethanol wer…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration1,6mM95 %
hplc with refractive index detector
"At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=5.9, substrate=CO2, steady_stateAusgeschlossen: kein SI-Wert
Product Concentration0,12g/L95 %
hplc with refractive index detector
"Acetate and ethanol titers (g/L) Ac 0.60 ± 0.03 Eth 0.12 ± 0.05" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
Acetic Acid Concentration2,7mM95 %
hplc with refractive index detector
"When 50% CO was included in the 20% CO2 gas with 10 mA applied current, acetate …" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_stateAusgeschlossen: kein SI-Wert
25 von 42 angezeigt

Literatur-Priors

Verteilung

Im Vergleich zur Literatur

Der in der Publikation berichtete Wert (▼) ist auf der Literaturverteilung aus MESS-Parameters eingezeichnet. Werte außerhalb des Bands werden als Ausreißer gekennzeichnet.

Coulombic efficiency8Prozent

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

The authors investigated the use of a bioelectrochemical system with low electric current to facilitate ethanol production from CO using a CO-enriched mixed culture.

Biologische Parameter

FeldWert
dominant species["Clostridium"]

Leistungskennzahlen

FeldWert
coulombic efficiency8
citation count3

Betriebsparameter

FeldWert
substrate["acetate","ethanol"]

Betriebsbedingungen

16 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-0fff8aa2a44bcf21375—CO and CO2——steady_state———
v2-379f9afb6ff07aaf375—CO and CO2————-0.8—
v2-3e184a9e73909e31375—CO and CO2————-1—
v2-58a2540478c500d825—————————
v2-6f336e1a25fe9d19375—CO and CO2——steady_state—-1—
v2-75cc08d7def72fd4375—CO and CO2——batch———
v2-96c77d8d0ebbb066——————startup———
v2-9ac075bcf106f8c1375.9—CO2——steady_state—-0.8—
v2-ab45e64a47441279375—CO and CO2——steady_state—-0.8—
v2-c3f11826babebaa6375—CO and CO2——————
v2-c3fbc7e70c689b34375—CO and CO2——startup—-0.8—
v2-c65079053aa9e59f376.2—CO2——startup—-1—
v2-d8c3a00ee3938b79376.2—CO2——steady_state—-1—
v2-df95e568afbdce74375.9—CO2——startup—-0.8—
v2-f3c38fe8acc74b70375—CO and CO2——startup—-1—
v2-f586e9af22985397——————————

Ergebnisse

Was gemessen wurde und was funktioniert hat

Kernaussagen

Coulombic efficiency

Elektrochemie

8Prozent

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

63 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

70 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

95 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

91 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches mikrobielles elektrochemisches System

Repräsentatives Modell: mikrobielles elektrochemisches System – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MES
System
86,0Prozent
Bestes Ergebnis · Coulomb-Effizienz
bester von 5
42
Extrahierte Werte
2024
Jahr

In diesem Datensatz

Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.

Schlagwörter

  • Pulp and paper industry
  • Fermentation
  • Microbial fuel cell
  • Ethanol fuel
  • Raw material
  • Faraday efficiency

Zitieren

Chaeho Im, Minsoo Kim, Jung Rae Kim et al. (2024). Low electric current in a bioelectrochemical system facilitates ethanol production from CO using CO-enriched mixed culture. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2024.1438758

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen