Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Publikation · MES
Low electric current in a bioelectrochemical system facilitates ethanol production from CO using CO-enriched mixed culture
Zusammenfassung
Was die Publikation berichtet, in ihren eigenen Worten.
Zusammenfassung
Fossil resources must be replaced by renewable resources in production systems to mitigate green-house gas emissions and combat climate change. Electro-fermentation utilizes a bioelectrochemical system (BES) to valorize industrial and municipal waste. Current electro-fermentation research is mainly focused on microbial electrosynthesis using CO 2 for producing commodity chemicals and replacing petroleum-based infrastructures. However, slow production rates and low titers of metabolites during CO 2 -based microbial electrosynthesis impede its implementation to the real application in the near future. On the other hand, CO is a highly reactive gas and an abundant feedstock discharged from fossil fuel-based industry. Here, we investigated CO and CO 2 electro-fermentation, using a CO-enriched culture. Fresh cow fecal waste was enriched under an atmosphere of 50% CO and 20% CO 2 in N 2 using serial cultivation. The CO-enriched culture was dominated by Clostridium autoethanogenum (≥89%) and showed electro-activity in a BES reactor with CO 2 sparging. When 50% CO was included in the 20% CO 2 gas with 10 mA applied current, acetate and ethanol were produced up to 12.9 ± 2.7 mM and 2.7 ± 1.1 mM, respectively. The coulombic efficiency was estimated to 148% ± 8% without an electron mediator. At 25 mA, the culture showed faster initial growth and acetate production but no ethanol production, and only at 86% ± 4% coulombic efficiency. The maximum optical density (OD) of 10 mA and 25 mA reactors were 0.29 ± 0.07 and 0.41 ± 0.03, respectively, whereas it was 0.77 ± 0.19 without electric current. These results show that CO electro-fermentation at low current can be an alternative way of valorizing industrial waste gas using a bioelectrochemical system.
KI-Zusammenfassung
95 % KonfidenzBES research focusing on bacteria, power, substrate. Fossil resources must be replaced by renewable resources in production systems to mitigate green-house gas emissions and combat climate change. Electro-fermentation utilizes a bioelectrochemic...
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Extrahierte Werte
Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.
n = 42 extrahierte Werte
Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.
8 von 40 extrahierten Zeilen modellierbar
- 5 nicht kanonisiert (kein kanonischer Slug)
- 27 kein SI-Wert
| Parameter | Wert | Einheit | Konfidenz | Quelle | Anmerkungen | Modellierbar |
|---|---|---|---|---|---|---|
| Substrate | acetate,ethanol | — | 80 % | llm | ||
| Coulombic efficiency | 8 | % | 80 % | llm | ||
| Acetic Acid Concentration | 5,8 | mM | 95 % | hplc with refractive index detector | "While no acetate production was observed in the abiotic experiment, formate was …" · T=37°C, pH(an)=5, substrate=CO and CO2 | Ausgeschlossen: kein SI-Wert |
| Relative Abundance | 89,1 | % | 95 % | 16s rrna sequencing (v1-v2 primer set) | "The majority of the bacterial community (≥89%) was found to consist of Clostridi…" · T=37°C, pH(an)=5, substrate=CO and CO2 | Modellierbar |
| Acetic Acid Concentration | 11,3 | mM | 95 % | hplc with refractive index detector | "At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=5.9, substrate=CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 12,9 | mM | 95 % | hplc with refractive index detector | "At the end of the experiment, 12.9 ± 2.7 mM acetate and 2.7 ± 1.1 mM ethanol wer…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Biomass Concentration | 0,3 | — | 95 % | spectrophotometry at 600 nm | "When 10 mA of electric current was applied, the maximum OD was lower (0.30 ± 0.0…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 6,8 | mM | 95 % | hplc with refractive index detector | "At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=6.2, substrate=CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 3 | mM | 95 % | hplc with refractive index detector | "While no acetate production was observed in the abiotic experiment, formate was …" · T=37°C, pH(an)=5, substrate=CO and CO2 | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 16,9 | mM | 95 % | hplc with refractive index detector | "When no electric current was applied, the maximum OD, 0.78 ± 0.19, was achieved …" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Biomass Concentration | 0,77 | — | 95 % | spectrophotometry at 600 nm | "The maximum optical density (OD) of 10 mA and 25 mA reactors were 0.29 ± 0.07 an…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Biomass Concentration | 0,42 | — | 95 % | spectrophotometry at 600 nm | "The maximum OD reached 0.42 ± 0.04 on day 2, and 15.3 ± 3.0 mM of acetate was de…" · T=37°C, pH(an)=5, substrate=CO and CO2, startup | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 15,3 | mM | 95 % | hplc with refractive index detector | "The maximum OD reached 0.42 ± 0.04 on day 2, and 15.3 ± 3.0 mM of acetate was de…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 0,6 | g/L | 95 % | hplc with refractive index detector | "Acetate and ethanol titers (g/L) Ac 0.60 ± 0.03 Eth 0.12 ± 0.05" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Modellierbar |
| Specific Growth Rate | 0,044 | h⁻¹ | 95 % | spectrophotometry at 600 nm | "The cell growth rate in the 25 mA reactor was faster (μ = 0.044 ± 0.001 h−1) tha…" · T=37°C, pH(an)=6.2, substrate=CO2, startup | Modellierbar |
| Specific Growth Rate | 0,011 | h⁻¹ | 95 % | spectrophotometry at 600 nm | "The cell growth rate in the 25 mA reactor was faster (μ = 0.044 ± 0.001 h−1) tha…" · T=37°C, pH(an)=5.9, substrate=CO2, startup | Modellierbar |
| Relative Abundance | 94,3 | % | 95 % | 16s rrna sequencing (v3-v4 primer set) | "The majority of the bacterial community (≥89%) was found to consist of Clostridi…" · T=37°C, pH(an)=5, substrate=CO and CO2 | Modellierbar |
| Relative Abundance | 4,03 | % | 95 % | 16s rrna sequencing (v3-v4 primer set) | "Lacticaseobacillus chiayiensis (4% with primers V3–V4)" · T=37°C, pH(an)=5, substrate=CO and CO2 | Modellierbar |
| Relative Abundance | 7,49 | % | 95 % | 16s rrna sequencing (v1-v2 primer set) | "The second most frequent bacterial species of the enriched community was identif…" · T=37°C, pH(an)=5, substrate=CO and CO2 | Modellierbar |
| Acetic Acid Concentration | 1,2 | mM | 95 % | hplc with refractive index detector | "At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=6.2, substrate=CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 0,72 | g/L | 95 % | hplc with refractive index detector | "Acetate and ethanol titers (g/L) ... Ac 0.72 ± 0.14" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Modellierbar |
| Acetic Acid Concentration | 2,7 | mM | 95 % | hplc with refractive index detector | "At the end of the experiment, 12.9 ± 2.7 mM acetate and 2.7 ± 1.1 mM ethanol wer…" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 1,6 | mM | 95 % | hplc with refractive index detector | "At the end of the experiments, concentrations of 11.3 ± 0.9 mM acetate and 1.6 ±…" · T=37°C, pH(an)=5.9, substrate=CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Product Concentration | 0,12 | g/L | 95 % | hplc with refractive index detector | "Acetate and ethanol titers (g/L) Ac 0.60 ± 0.03 Eth 0.12 ± 0.05" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
| Acetic Acid Concentration | 2,7 | mM | 95 % | hplc with refractive index detector | "When 50% CO was included in the 20% CO2 gas with 10 mA applied current, acetate …" · T=37°C, pH(an)=5, substrate=CO and CO2, steady_state | Ausgeschlossen: kein SI-Wert |
Literatur-Priors
Im Vergleich zur Literatur
Der in der Publikation berichtete Wert (▼) ist auf der Literaturverteilung aus MESS-Parameters eingezeichnet. Werte außerhalb des Bands werden als Ausreißer gekennzeichnet.
Methodik
Welches System und wie es betrieben wurde
Methodik
Methodology
The authors investigated the use of a bioelectrochemical system with low electric current to facilitate ethanol production from CO using a CO-enriched mixed culture.
Biologische Parameter
| Feld | Wert |
|---|---|
| dominant species | ["Clostridium"] |
Leistungskennzahlen
| Feld | Wert |
|---|---|
| coulombic efficiency | 8 |
| citation count | 3 |
Betriebsparameter
| Feld | Wert |
|---|---|
| substrate | ["acetate","ethanol"] |
Betriebsbedingungen
16 Läufe extrahiert| Lauf | T°C | pHAnolyt | pHKatholyt | Substrat | [S]mg/L | HRTh | Modus | R_extΩ | V_appV | Inokulum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-0fff8aa2a44bcf21 | 37 | 5 | — | CO and CO2 | — | — | steady_state | — | — | — |
| v2-379f9afb6ff07aaf | 37 | 5 | — | CO and CO2 | — | — | — | — | -0.8 | — |
| v2-3e184a9e73909e31 | 37 | 5 | — | CO and CO2 | — | — | — | — | -1 | — |
| v2-58a2540478c500d8 | 25 | — | — | — | — | — | — | — | — | — |
| v2-6f336e1a25fe9d19 | 37 | 5 | — | CO and CO2 | — | — | steady_state | — | -1 | — |
| v2-75cc08d7def72fd4 | 37 | 5 | — | CO and CO2 | — | — | batch | — | — | — |
| v2-96c77d8d0ebbb066 | — | — | — | — | — | — | startup | — | — | — |
| v2-9ac075bcf106f8c1 | 37 | 5.9 | — | CO2 | — | — | steady_state | — | -0.8 | — |
| v2-ab45e64a47441279 | 37 | 5 | — | CO and CO2 | — | — | steady_state | — | -0.8 | — |
| v2-c3f11826babebaa6 | 37 | 5 | — | CO and CO2 | — | — | — | — | — | — |
| v2-c3fbc7e70c689b34 | 37 | 5 | — | CO and CO2 | — | — | startup | — | -0.8 | — |
| v2-c65079053aa9e59f | 37 | 6.2 | — | CO2 | — | — | startup | — | -1 | — |
| v2-d8c3a00ee3938b79 | 37 | 6.2 | — | CO2 | — | — | steady_state | — | -1 | — |
| v2-df95e568afbdce74 | 37 | 5.9 | — | CO2 | — | — | startup | — | -0.8 | — |
| v2-f3c38fe8acc74b70 | 37 | 5 | — | CO and CO2 | — | — | startup | — | -1 | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Ergebnisse
Was gemessen wurde und was funktioniert hat
Kernaussagen
Coulombic efficiency
Elektrochemie8Prozent
Extraktionspipeline
Rohextraktionen, Artefakte, Qualitätssignal
Extraktionsqualität
EhrlichkeitssignalBemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.
Parametervollständigkeit
63 %
Anteil der erwarteten Parameter, die extrahiert wurden
Datenvollständigkeit
70 %
Gesamtabdeckung der Extraktion über alle Felder
KI-Konfidenz
95 %
Vom Modell selbst angegebene Konfidenz
Mittlere Parameterkonfidenz
91 %
Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen
vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1
Diagramm-Explorer
Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.
Modell erkunden
Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.
KI-Erkenntnisse
Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.
Ähnliche Publikationen vergleichen
Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.
Quell-PDF
Die Publikation, wie sie erschienen ist.
Repräsentatives Modell, generisches mikrobielles elektrochemisches System
Zum Interagieren tippenRepräsentatives Modell, generisches mikrobielles elektrochemisches System
Repräsentatives Modell: mikrobielles elektrochemisches System – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.
In diesem Datensatz
Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.
Organismen · 1
Parameter · 1
Schlagwörter
- Pulp and paper industry
- Fermentation
- Microbial fuel cell
- Ethanol fuel
- Raw material
- Faraday efficiency
Zitieren
Chaeho Im, Minsoo Kim, Jung Rae Kim et al. (2024). Low electric current in a bioelectrochemical system facilitates ethanol production from CO using CO-enriched mixed culture. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2024.1438758
- Zeitschrift
- Frontiers in Microbiology
Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.
Im Labor öffnen