Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Publikation · MES
Efficient Hydrogen Delivery for Microbial Electrosynthesis via 3D-Printed Cathodes
Zusammenfassung
Was die Publikation berichtet, in ihren eigenen Worten.
Zusammenfassung
The efficient delivery of electrochemically in situ produced H 2 can be a key advantage of microbial electrosynthesis over traditional gas fermentation. However, the technical details of how to supply large amounts of electric current per volume in a biocompatible manner remain unresolved. Here, we explored for the first time the flexibility of complex 3D-printed custom electrodes to fine tune H 2 delivery during microbial electrosynthesis. Using a model system for H 2 -mediated electromethanogenesis comprised of 3D fabricated carbon aerogel cathodes plated with nickel-molybdenum and Methanococcus maripaludis , we showed that novel 3D-printed cathodes facilitated sustained and efficient electromethanogenesis from electricity and CO 2 at an unprecedented volumetric production rate of 2.2 L CH4 /L catholyte /day and at a coulombic efficiency of 99%. Importantly, our experiments revealed that the efficiency of this process strongly depends on the current density. At identical total current supplied, larger surface area cathodes enabled higher methane production and minimized escape of H 2 . Specifically, low current density (<1 mA/cm 2 ) enabled by high surface area cathodes was found to be critical for fast start-up times of the microbial culture, stable steady state performance, and high coulombic efficiencies. Our data demonstrate that 3D-printing of electrodes presents a promising design tool to mitigate effects of bubble formation and local pH gradients within the boundary layer and, thus, resolve key critical limitations for in situ electron delivery in microbial electrosynthesis.
Extrahierte Werte
Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.
n = 17 extrahierte Werte
Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.
6 von 17 extrahierten Zeilen modellierbar
- 1 nicht kanonisiert (kein kanonischer Slug)
- 2 kein SI-Wert
- 4 Verifizierer hat den Wert abgelehnt
- 4 widerspricht anderen Publikationen
| Parameter | Wert | Einheit | Konfidenz | Quelle | Anmerkungen | Modellierbar |
|---|---|---|---|---|---|---|
| Coulombic efficiency×4 | 99 | % | 90 % | extrahiert | "At 60 mA total current, the reactors with the three highest surface area cathode…" · T=30°C, pH(an)=7, substrate=CO2, steady_state | Ausgeschlossen: Verifizierer hat den Wert abgelehnt |
| Coulombic efficiency | 99 | % | 90 % | extrahiert | "corresponding to a volumetric methane production rate of 2.2 LCH4 /Lcatholyte/da…" · T=30°C, pH(an)=7, substrate=CO2, steady_state | Modellierbar |
| Coulombic efficiency | 97 | % | 90 % | extrahiert | "At 0.6 mA/cm2 highly efficient methane production was established only after 145…" · T=30°C, pH(an)=7, substrate=CO2, steady_state | Modellierbar |
| Coulombic efficiency | 98 | % | 90 % | extrahiert | "At the lowest current density of 0.5 mA/cm2 (high surface area), stable electrom…" · T=30°C, pH(an)=7, substrate=CO2, steady_state | Modellierbar |
| Coulombic efficiency | 20 | % | 90 % | extrahiert | "resulted in an overall low coulombic efficiency of 20 ± 4% for methane (averaged…" · T=30°C, pH(an)=7, substrate=CO2 | Ausgeschlossen: widerspricht anderen Publikationen |
| Coulombic efficiency | 12 | % | 90 % | extrahiert | "the average coulombic efficiency for methane was only 12 ± 2%" · T=30°C, pH(an)=7, substrate=CO2 | Ausgeschlossen: widerspricht anderen Publikationen |
| Startup Time×2 | 7 | h | 90 % | extrahiert | "For current densities of 0.5 and 0.6 mA/cm2, highly efficient methane production…" · T=30°C, pH(an)=7, substrate=CO2 | Modellierbar |
| CH₄ Production Rate | 1 | other | 90 % | extrahiert | "Increasing the current to 70 mA led to an increase in methane production rate, e…" · T=30°C, pH(an)=7, substrate=CO2 | Ausgeschlossen: kein SI-Wert |
| Startup Time | 55 | h | 90 % | extrahiert | "At a current density of 0.9 mA/cm2, steady state methane production was reached …" · T=30°C, pH(an)=7, substrate=CO2 | Ausgeschlossen: widerspricht anderen Publikationen |
| Startup Time | 24 | h | 90 % | extrahiert | "stable electromethanogenesis was observed within 24 h" · T=30°C, pH(an)=7, substrate=CO2 | Modellierbar |
| Hydrogen in Reactor Off-gas | 1 | other | 90 % | extrahiert | "With increasing current density, steady state operation was delayed and H2 conce…" · T=30°C, pH(an)=7, substrate=CO2 | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Startup Time | 145 | h | 90 % | extrahiert | "highly efficient methane production was established only after 145 h" · T=30°C, pH(an)=7, substrate=CO2 | Ausgeschlossen: widerspricht anderen Publikationen |
| CH₄ Production Rate | 2,2 | LCH4/Lcatholyte/day | 90 % | extrahiert | "corresponding to a volumetric methane production rate of 2.2 LCH4 /Lcatholyte/da…" · T=30°C, pH(an)=7, substrate=CO2, steady_state | Ausgeschlossen: kein SI-Wert |
Methodik
Welches System und wie es betrieben wurde
Betriebsbedingungen
2 Läufe extrahiert| Lauf | T°C | pHAnolyt | pHKatholyt | Substrat | [S]mg/L | HRTh | Modus | R_extΩ | V_appV | Inokulum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-0cd05285734d985a | 30 | 7 | — | CO2 | — | — | steady_state | — | — | — |
| v2-5fdc0b1496fa68b1 | 30 | 7 | — | CO2 | — | — | — | — | — | — |
Extraktionspipeline
Rohextraktionen, Artefakte, Qualitätssignal
Extraktionsqualität
EhrlichkeitssignalBemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.
KI-Konfidenz
60 %
Vom Modell selbst angegebene Konfidenz
Mittlere Parameterkonfidenz
90 %
Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen
vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1
Diagramm-Explorer
Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.
Modell erkunden
Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.
KI-Erkenntnisse
Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.
Ähnliche Publikationen vergleichen
Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.
Quell-PDF
Die Publikation, wie sie erschienen ist.
Repräsentatives Modell, generisches mikrobielles elektrochemisches System
Zum Interagieren tippenRepräsentatives Modell, generisches mikrobielles elektrochemisches System
Repräsentatives Modell: mikrobielles elektrochemisches System – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.
In diesem Datensatz
Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.
Organismen · 1
Schlagwörter
- Electrosynthesis
- Faraday efficiency
- Cathode
- Nanotechnology
- Hydrogen production
- Electrode
Zitieren
Frauke Kracke, Jörg S. Deutzmann, Buddhinie Srimali Jayathilake et al. (2021). Efficient Hydrogen Delivery for Microbial Electrosynthesis via 3D-Printed Cathodes. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2021.696473
- PubMed
- 34413839
- Zeitschrift
- Frontiers in Microbiology
Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.
Im Labor öffnen