Energy Consumption for Nutrient Removal from High-Nitrate and High-Phosphorus Wastewater in Aerobic and Anaerobic Bioelectrochemical Reactors
- BER
- Dual Chamber
- Bioanode Only
- Mixed Culture
- Anode: Bioanode
- mixed culture biofilm
Zusammenfassung
Was die Publikation berichtet, in ihren eigenen Worten.
Zusammenfassung
An attempt was undertaken to determine indicators of energy consumption in bio-electro reactors (BERs) i.e., an aerobic rotating electrobiological disc contactor (REBDC) and an anaerobic sequencing batch biofilm reactor (SBBR), during contaminant removal from soilless tomato cultivation wastewater having a specific composition, i.e., high nitrate and phosphorus concentrations and low COD. Because of this specificity, the energy consumption during the treatment process was characterized by a cumulative indicator for simultaneous removal of phosphorus and nitrates—EEINUTRIENTSrem (electric energy consumption per unit of removed nutrient load, expressed as kWh/kgNUTRIENTSrem). Four values of direct current density were tested: 0.63, 1.25, 2.5, and 5.0 A/m². The indicator values were compared at a hydraulic retention time (HRT) of 24 h. The study demonstrated that the values of electric energy consumption per unit of removed nutrient load determined in the anaerobic SBBR ranged from 30 to 464 kWh/kg NUTRIENTSrem and were lower than the values obtained in the aerobic REBCD, i.e., 80–1380 kWh/kg NUTRIENTSrem.
KI-Zusammenfassung
72 % KonfidenzZentrale Erkenntnisse
Zielkonflikt In anaerobic SBBR at 0.63–5.0 A/m² and 24 h HRT, EEITNrem ranged 49–144.5 kWh/kg TNrem versus 398–1945 kWh/kg TNrem in aerobic REBDC—an 8- to 13-fold difference—despite lower denitrification efficiency (36.5% vs 68.6%).
Was heißt das. Operators treating high-nitrate, low-COD wastewater should prioritize anaerobic BER designs over aerobic ones if energy cost per kg nutrient removed is the primary constraint, even if absolute removal rates are lower.
Zielkonflikt In REBDC, extending HRT from 4 to 24 h at constant current density increased EEITNrem (e.g., 0.63 A/m²: 118→398 kWh/kg TNrem) despite improving removal effectiveness, creating a paradoxical energetic penalty for higher treatment efficiency.
Was heißt das. Do not assume longer residence time always improves energy efficiency; test the operating window where removal rate gain per unit time exceeds the energy cost of extended contact.
Zielkonflikt Phosphorus removal in REBDC was far more energy-intensive than nitrogen: EEITPrem reached 9456 kWh/kg TPrem (10.0 A/m², 24 h HRT) versus EEITNrem of 2170 kWh/kg TNrem under identical conditions—a 4.4× penalty.
Was heißt das. If phosphorus removal is the bottleneck, consider electrocoagulation as a separate post-treatment step rather than simultaneous removal, or accept higher energy cost as a trade-off for single-reactor simplicity.
Schwellenwert Current density increase from 0.63 to 10.0 A/m² in REBDC caused EEINUTRIENTSrem to rise from 80–330 to 600–1990 kWh/kg NUTRIENTSrem (2.4–6× increase), indicating diminishing returns on current input for nutrient removal efficiency.
Was heißt das. Operate REBDC at 0.63–1.25 A/m² to minimize energy cost per kg nutrient; higher current densities should only be used if treatment time constraints override energy efficiency.
Mechanismus Phosphorus removal effectiveness in REBDC exceeded 90% even at the lowest current density (0.63 A/m², 4 h HRT) and reached 99%+ at 10.0 A/m², whereas nitrogen removal peaked at 68.6% only at maximum current and HRT, indicating phosphorus is electrochemically favored over biological denitrification.
Was heißt das. Design for nitrogen removal kinetics as the limiting step; phosphorus will follow automatically, allowing you to optimize HRT and current for N removal without worrying about P breakthrough.
Widersprüche2
Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.
Innerhalb der Publikation Nitrogen removal effectiveness increases with HRT extension, yet energy cost per kg N removed also increases—a paradox the authors acknowledge but do not fully explain mechanistically.
Eine SeiteHRT extension improves removal effectiveness: 'Our previous research [27] demonstrated the highest nitrogen removal effectiveness (68.6%) at the highest electric current density and the longest hydraulic retention time. At all current densities tested, the effectiveness of nitrogen removal increased along with extended hydraulic retention time.'
“the highest nitrogen removal effectiveness (68.6%) at the highest electric current density and the longest hydraulic retention time”
Andere SeiteHRT extension increases energy cost per kg removed: 'HRT extension at a stable current density ensured both a technological effect, i.e., increased effectiveness of nitrogen removal, and a direct energetic effect, i.e., increased energy demand per unit of removed contaminant load.'
“HRT extension at a stable current density ensured both a technological effect, i.e., increased effectiveness of nitrogen removal, and a direct energetic effect, i.e., increased energy demand per unit of removed contaminant load”
Einordnung der Autoren. The authors observe the paradox but attribute it to the cumulative energy input (U·I·t in the numerator) growing faster than the incremental removal load in the denominator. This suggests that at longer HRT, the system reaches a plateau in removal rate while current continues to flow, wasting energy. The paper does not investigate whether this is due to kinetic limitation, biofilm saturation, or electrode potential constraints.
Innerhalb der Publikation Anaerobic SBBR achieves 8–13× lower energy cost per kg N removed than aerobic REBDC, yet absolute denitrification efficiency is lower (36.5% vs 68.6%), implying the anaerobic system removes less N per unit time but uses far less energy per unit removed.
Eine SeiteAnaerobic SBBR is more energy-efficient: 'In the SBBR, the values of the energy consumption during nutrient removal (Figure 5) ranged from 30 to 464 kWh/kg NUTRIENTSrem, whereas, in the REBDC, they reached 330 and 1380 kWh/kg NUTRIENTSrem.'
“the values of the energy consumption during nutrient removal (Figure 5) ranged from 30 to 464 kWh/kg NUTRIENTSrem, whereas, in the REBDC, they reached 330 and 1380 kWh/kg NUTRIENTSrem”
Andere SeiteAnaerobic SBBR has lower removal efficiency: 'The denitrification efficiency reached 36.5% at the lowest current density and 21.9% at the highest one.' vs. aerobic REBDC: 'the highest nitrogen removal effectiveness (68.6%) at the highest electric current density and the longest hydraulic retention time'
“The denitrification efficiency reached 36.5% at the lowest current density and 21.9% at the highest one”
Einordnung der Autoren. The authors do not reconcile this directly. The likely explanation is that the anaerobic SBBR operates at lower cell voltage or current density (0.63–5.0 A/m² vs 0.63–10.0 A/m² in REBDC), reducing energy input per unit time, and that the lower removal efficiency is acceptable if the goal is energy minimization rather than maximum treatment. The paper does not compare removal rates (kg/h) or discuss whether the anaerobic system could achieve higher efficiency with longer HRT.
Ansatzpunkte6
Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.
Hoch No investigation of nitrite (NO₂⁻) or N₂O accumulation across the current density and HRT matrix, despite these being critical indicators of denitrification pathway selectivity and greenhouse gas risk in bioelectrochemical systems.
The paper measures influent NO₂⁻ (0.092 mg N/L mean) and effluent NO₃⁻ and TN, but does not report effluent NO₂⁻ or N₂O at any condition. Given that electrochemical reduction can produce NO₂⁻ as an intermediate and that incomplete denitrification produces N₂O, the absence of these data prevents assessment of whether higher current densities or longer HRT favor complete denitrification or accumulation of intermediates.
Versuch. Measure NO₂⁻ and N₂O (headspace gas chromatography or dissolved via membrane inlet MS) at each combination of J (0.63, 1.25, 2.5, 5.0, 10.0 A/m²) and HRT (4, 8, 12, 24 h) in REBDC and at J (0.63–5.0 A/m²), HRT 24 h in SBBR. Correlate with current efficiency and identify the operating window that minimizes NO₂⁻ and N₂O while maximizing N₂ production.
Hoch No measurement of cathode and anode potentials (vs. Ag/AgCl or SHE) or cell voltage breakdown, making it impossible to identify which electrode limits performance or whether potential windows can be optimized for selective denitrification vs. phosphorus removal.
The paper applies current density (J) and measures total cell voltage (U) but does not report individual electrode potentials. Since hydrogenotrophic denitrification requires a specific cathode potential window for H₂ production and denitrifier activity, and electrocoagulation requires a specific anode potential for Al dissolution, the absence of potential data prevents mechanistic understanding and optimization.
Versuch. Install reference electrodes (Ag/AgCl, +0.197 V vs. SHE) in both REBDC and SBBR. At each J and HRT, measure and report cathode potential (Ecath), anode potential (Eanode), and cell voltage (U = Eanode − Ecath). Correlate Ecath with H₂ production rate (gas chromatography) and denitrification efficiency; correlate Eanode with Al dissolution rate (ICP-OES) and phosphorus removal. Identify the potential windows that maximize current efficiency for each process.
Mittel No systematic variation of influent C/N ratio or external carbon source type; sodium acetate was added but its concentration and the resulting C/N ratio are not reported, limiting reproducibility and generalizability to other wastewater types.
The paper states 'sodium acetate was added to wastewater as a source of carbon to ensure the growth of the biofilm biomass' but does not specify the acetate concentration, the resulting C/N ratio, or whether this ratio was optimized. The influent TN is 486 mg N/L and COD (with acetate) is 260 mg O₂/L, implying a very high N:C ratio. This may explain why nitrogen removal is incomplete and why the anaerobic SBBR achieves only 36.5% denitrification efficiency.
Versuch. Test influent C/N ratios of 0.5, 1.0, 2.0, and 4.0 (by varying acetate concentration) at fixed J = 1.25 A/m² and HRT = 24 h in both REBDC and SBBR. Measure TN removal efficiency, EEITNrem, and effluent NO₂⁻ and N₂O. Identify the C/N ratio that maximizes denitrification efficiency and minimizes energy cost per kg N removed.
Mittel No measurement of dissolved oxygen (DO) in the REBDC bulk liquid or biofilm profile, despite the paper claiming 'aerobic conditions' in the tank and 'transitional and anaerobic layers' in the biofilm. DO is critical for nitrification and oxygen-dependent denitrification pathways.
The paper assumes aerobic conditions in REBDC based on disc submergence (40%) and aeration, but does not measure DO. If DO is low or depleted, nitrification may be incomplete, and the measured TN removal may be dominated by electrochemical reduction rather than biological denitrification, affecting the interpretation of energy efficiency and the applicability to other systems.
Versuch. Install DO probes (optical or electrochemical) in the REBDC bulk liquid and use microelectrodes to profile DO in the biofilm at disc surface, mid-depth, and base. Measure at J = 0.63, 2.5, and 10.0 A/m² and HRT = 4, 12, 24 h. Correlate DO profile with TN removal pathway (nitrification vs. electrochemical reduction vs. heterotrophic denitrification) using 15N-labeled substrates or molecular methods.
Mittel No investigation of the effect of influent pH or catholyte pH on nitrogen and phosphorus removal, despite pH being a critical variable for electrochemical reactions, H₂ production, and denitrifier activity.
The paper reports influent pH of 6.19 ± 0.11 but does not measure effluent pH or pH in the cathode and anode compartments. Electrochemical H₂ production is pH-dependent (more favorable at low pH), and denitrification is sensitive to pH (optimal ~7–7.5). Phosphorus precipitation (electrocoagulation) is also pH-dependent. Without pH data, the mechanisms and optimization potential are unclear.
Versuch. Measure influent and effluent pH at each J and HRT condition. In REBDC, measure pH in the bulk liquid and at the cathode surface (using pH microelectrodes). In SBBR, measure pH in the bulk liquid and in the anode and cathode compartments (if separated). Vary influent pH from 5.5 to 8.0 at fixed J = 1.25 A/m² and HRT = 24 h. Measure TN removal, EEITNrem, H₂ production rate, and effluent NO₂⁻ and N₂O. Identify the pH window that maximizes energy efficiency.
Mittel No comparison of the two reactor types at identical HRT and current density ranges; SBBR was tested only at 24 h HRT and 0.63–5.0 A/m², while REBDC was tested at 4–24 h HRT and 0.63–10.0 A/m², preventing direct assessment of whether the anaerobic advantage holds across the full operating window.
The paper justifies limiting SBBR testing to 24 h HRT and 5.0 A/m² based on REBDC results (temperature rise at 10.0 A/m²), but this creates an incomplete comparison. It is unclear whether the anaerobic advantage persists at shorter HRT (4, 8, 12 h) or at higher current density (10.0 A/m²), or whether the SBBR would show similar energy penalties at longer HRT.
Versuch. Conduct a full factorial test of SBBR at J = 0.63, 1.25, 2.5, 5.0, 10.0 A/m² and HRT = 4, 8, 12, 24 h (with temperature control to prevent >50 °C). Compare EEINUTRIENTSrem, EEITNrem, EEITPrem, and removal efficiencies directly to REBDC results. Identify the operating window where anaerobic SBBR is superior and where aerobic REBDC may be preferable (e.g., if higher removal efficiency is needed despite higher energy cost).
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Extrahierte Werte
Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.
n = 117 extrahierte Werte
Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.
22 von 112 extrahierten Zeilen modellierbar
- 2 nicht kanonisiert (kein kanonischer Slug)
- 88 kein SI-Wert
| Parameter | Wert | Einheit | Konfidenz | Quelle | Anmerkungen | Modellierbar |
|---|---|---|---|---|---|---|
| Hydraulic retention time | 24 | h | 95 % | llm | abstract | |
| Current Density | 0,63 | A/m² | 95 % | llm | abstract | |
| Substrate | — | — | 90 % | llm | ||
| Chemical Oxygen Demand (COD) Concentration | 37,4 | mg_O₂/L | 90 % | llm | results | |
| Power Density | 30 | kWh/kg_NUTRIENTSrem | 90 % | llm | abstract | |
| Chamber Volume×2 | 2 | L | 95 % | extrahiert | "The experiment was carried out in four single-stage rotating contactors with tec…" · condition_hint=reactor design parameter for both REBDC and SBBR | Modellierbar |
| Electrode Surface Area×2 | 0,113 | m² | 95 % | extrahiert | "The experiment was carried out in four single-stage rotating contactors with tec…" · condition_hint=SBBR reactor design parameter, electrode_material=stainless-steel discs | Modellierbar |
| Electrode Surface Area×2 | 0,56 | m² | 95 % | extrahiert | "The experiment was carried out in four single-stage rotating contactors with tec…" · condition_hint=REBDC reactor design parameter, electrode_material=stainless-steel discs | Modellierbar |
| Ammonium Ion Concentration×2 | 18 | mg N/L | 90 % | extrahiert | "The composition of wastewater used in the study is presented in Table 2 [27]. Am…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater | Ausgeschlossen: kein SI-Wert |
| Electrolyte Conductivity×2 | 6 | mS/cm | 90 % | extrahiert | "The composition of wastewater used in the study is presented in Table 2 [27]. El…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater | Modellierbar |
| Nitrate concentration in influent×2 | 471 | mg N/L | 90 % | extrahiert | "The composition of wastewater used in the study is presented in Table 2 [27]. Ni…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater | Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug) |
| Influent Total Nitrogen (TN)×2 | 486 | mg N/L | 90 % | extrahiert | "The composition of wastewater used in the study is presented in Table 2 [27]. To…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater | Ausgeschlossen: kein SI-Wert |
| Influent Total Phosphorus (TP)×2 | 77,5 | mg P/L | 90 % | extrahiert | "The composition of wastewater used in the study is presented in Table 2 [27]. To…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater | Ausgeschlossen: kein SI-Wert |
| Specific Energy Consumption×2 | 611 | kWh/kg TPrem | 85 % | electrochemical measurement with direct current | "At the current density of 0.63 A/m2, the EEITPrem values ranged from 104 to 611 …" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Ausgeschlossen: kein SI-Wert |
| Phosphorus Removal×2 | 91,2 | % | 85 % | electrochemical measurement with direct current | "Here, the dephosphatation effectiveness exceeded 90% at both electric current de…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Modellierbar |
| Nitrate Removal×2 | 36,5 | % | 85 % | electrochemical measurement with direct current | "The denitrification efficiency reached 36.5% at the lowest current density and 2…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Modellierbar |
| Phosphorus Removal×2 | 81 | % | 85 % | electrochemical measurement with direct current | "Our previous study [27] demonstrated phosphorus removal effectiveness of 81.0% a…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Modellierbar |
| Nitrogen Removal×2 | 68,6 | % | 85 % | electrochemical measurement with direct current | "It is worth noting that our previous research [27] demonstrated the highest nitr…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Modellierbar |
| Phosphorus Removal×2 | 95,8 | % | 85 % | electrochemical measurement with direct current | "Here, the dephosphatation effectiveness exceeded 90% at both electric current de…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Modellierbar |
| Phosphorus Removal×2 | 99,8 | % | 85 % | electrochemical measurement with direct current | "Our previous study [27] demonstrated phosphorus removal effectiveness of 81.0% a…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Modellierbar |
| Specific Energy Consumption×2 | 49 | kWh/kg TNrem | 85 % | electrochemical measurement with direct current | "In the anaerobic sequencing batch biofilm reactor (SBBR), the values of the ener…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Ausgeschlossen: kein SI-Wert |
| Specific Energy Consumption×2 | 1.500 | kWh/kg TPrem | 85 % | electrochemical measurement with direct current | "At current densities of 5.00 A/m2 and 10.00 A/m2, HRT extension in the reactor f…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Ausgeschlossen: kein SI-Wert |
| Specific Energy Consumption×2 | 464 | kWh/kg NUTRIENTSrem | 85 % | electrochemical measurement with direct current | "In the SBBR, the values of the energy consumption during nutrient removal (Figur…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Ausgeschlossen: kein SI-Wert |
| Specific Energy Consumption×2 | 678 | kWh/kg TNrem | 85 % | electrochemical measurement with direct current | "At the current density of 1.25 A/m2 and the same HRTs, the EEITNrem values were …" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Ausgeschlossen: kein SI-Wert |
| Specific Energy Consumption×2 | 290 | kWh/kg TNrem | 85 % | electrochemical measurement with direct current | "The successive increase in the current density to 2.50 A/m2 caused a higher ener…" · T=20°C, pH(an)=6.19, substrate=soilless tomato cultivation wastewater with sodium acetate, steady_state | Ausgeschlossen: kein SI-Wert |
Methodik
Welches System und wie es betrieben wurde
Methodik
Methodology
Two laboratory-scale bioelectrochemical reactors (REBDC and SBBR) were operated in parallel stages. Stage 1 tested REBDC across four HRT values (4, 8, 12, 24 h) and four current densities (0.63, 1.25, 2.5, 5.0, 10.0 A/m²). Stage 2 tested SBBR at a single HRT (24 h) and four current densities (0.63, 1.25, 2.5, 5.0 A/m²), with the range limited based on Stage 1 results. Synthetic wastewater mimicking soilless tomato cultivation (486 mg N/L as NO₃⁻, 77.5 mg P/L, 260 mg O₂/L COD with added sodium acetate) was treated at ~20 °C. Influent and effluent were analyzed for TN, TP, NO₃⁻, NO₂⁻, NH₃-N, COD, pH, and conductivity. Energy consumption per unit removed nutrient load (EEILrem) was calculated using cell voltage, current, HRT, and removal load.
Biologische Parameter
| Feld | Wert |
|---|---|
| inoculum source | soil |
Leistungskennzahlen
| Feld | Wert |
|---|---|
| citation count | 8 |
Betriebsparameter
| Feld | Wert |
|---|---|
| substrate | ["wastewater"] |
Elektrochemische Daten
| Feld | Wert |
|---|---|
| max current density | 5 |
Betriebsbedingungen
21 Läufe extrahiert| Lauf | T°C | pHAnolyt | pHKatholyt | Substrat | [S]mg/L | HRTh | Modus | R_extΩ | V_appV | Inokulum |
|---|---|---|---|---|---|---|---|---|---|---|
| baseline_HRT_24h | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| baseline_HRT_24h #2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| baseline_HRT_24h #3 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_0.63_A_m2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_0.63_A_m2 #2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_0.63_A_m2 #3 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_1.25_A_m2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_1.25_A_m2 #2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_1.25_A_m2 #3 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_2.5_A_m2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_2.5_A_m2 #2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_2.5_A_m2 #3 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_5.0_A_m2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_5.0_A_m2 #2 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| current_density_5.0_A_m2 #3 | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| v2-4f11ada7348a029a | — | — | — | soilless tomato cultivation wastewater | — | 24 | continuous | — | — | — |
| v2-7ac0b034516299d6 | 20 | 6.19 | — | — | — | 24 | — | — | — | — |
| v2-9091896e6a5d02bd | 20 | 6.19 | — | soilless tomato cultivation wastewater with sodium acetate | — | — | steady_state | — | — | — |
| v2-bba35cc39305fdd9 | 20 | 6.19 | — | soilless tomato cultivation wastewater | — | — | — | — | — | — |
| v2-cb82af6e71382bc9 | 20 | 6.19 | — | soilless tomato cultivation wastewater with sodium acetate | — | — | — | — | — | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Extraktionspipeline
Rohextraktionen, Artefakte, Qualitätssignal
Extraktionsqualität
EhrlichkeitssignalBemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.
Parametervollständigkeit
50 %
Anteil der erwarteten Parameter, die extrahiert wurden
Datenvollständigkeit
60 %
Gesamtabdeckung der Extraktion über alle Felder
KI-Konfidenz
72 %
Vom Modell selbst angegebene Konfidenz
Mittlere Parameterkonfidenz
84 %
Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen
vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1
Diagramm-Explorer
Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.
Modell erkunden
Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.
KI-Erkenntnisse
Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.
Ähnliche Publikationen vergleichen
Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.
Quell-PDF
Die Publikation, wie sie erschienen ist.
Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die daraus extrahierten Werte stehen unter „Extrahierte Werte“.
In diesem Datensatz
Organismen, Parameter und Materialien, die diese Publikation berichtet. Jeder Eintrag verweist auf seine Seite.
Organismen · 1
- mixed culture biofilm
Materialien · 1
Schlagwörter
- Rotating biological contactor
- Hydraulic retention time
- Wastewater
- Nutrient
- Anaerobic exercise
- Phosphorus
Zitieren
Joanna Rodziewicz, Artur Mielcarek, Kamil Bryszewski et al. (2022). Energy Consumption for Nutrient Removal from High-Nitrate and High-Phosphorus Wastewater in Aerobic and Anaerobic Bioelectrochemical Reactors. Energies. https://doi.org/10.3390/en15197251
- Zeitschrift
- Energies