MESSAI.iO
Plattform
  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung
Labor
  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Methodik
Anwendungsfälle
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
Wissen
  • Die Wissenschaft
  • Handbuch
  • Whitepaper
Über uns

Sprache

  • Englishen
  • Deutschde

Plattform

  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung

Labor

  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Demo: Ressourcenrückgewinnung

Unternehmen

  • Über uns
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
  • Whitepaper
  • Handbuch
  • API-Dokumentation

Rechtliches

  • Datenschutz
  • Nutzungsbedingungen
  • Nachweise
  • Kontakt

MESSAI · KI für mikrobielle elektrochemische Systeme · © 2026

Jede Zahl auf dieser Website führt auf eine Quelldatei zurück – /proof

Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

← Zurück zur Forschung

High-rate ammonium removal and recovery and hydrogen production from wastewater using microbial electrolysis cell.

Bioresource technology·2026·doi.org/41435920
Interaktives 3D-ModellKI-angereichert· 75 %
SystemMEC

KI-Zusammenfassung

75 % Konfidenz

This study presents an integrated approach using microbial electrolysis cells (MECs) with external ammonium extraction systems for enhanced nitrogen removal and recovery from high-strength wastewater, achieving high ammonium removal and recovery rates, as well as hydrogen production. The MECs operated at 0.75 V and integrated with a thermally assisted stripping system showed the highest performances. The results highlight the potential of coupling MECs with stripping systems for efficient wastewater treatment and resource recovery.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Generic MECProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →

Was gemacht wurde

Systemtyp
MEC

Was funktioniert hat

Noch keine Ergebniskennzahlen extrahiert.

Zusammenfassung

This study presents an integrated approach combining microbial electrolysis cells (MECs) with three external ammonium extraction systems, Gas Diffuser (GD), Stripping Column (SP) and Thermally Assisted Stripping (SP + T), to enhance nitrogen removal and recovery from high-strength wastewater. Among the configurations, MECs operated at 0.75 V and integrated with SP + T achieved the highest performances, with current density of 8.8 A m -2 , ammonium removal and recovery rates reaching 69.8 and 37.9 gN m -2 d -1 , Faradaic efficiency of 74.9 % and specific energy consumption for ammonium recovery of 3.3 kWh kg -1 N. The SP + T system boosted ammonia volatilization at the catholyte and accelerated ammonium transport across the cation exchange membrane, leading to improved removal and recovery performance. Concurrently, H 2 generation reached 1557.6 L H 2 m -3 d -1 with specific energy consumption of 31.4 kWh kg -1 H 2 . These results highlight that coupling MEC and SP + T is a promising configuration for efficient nitrogen recovery and renewable hydrogen generation, while demonstrating MECs as a sustainable technology for wastewater treatment and resource recovery. STRUCTURED ABSTRACT: The study presents a novel approach for enhancing nitrogen recovery from wastewater using MECs integrated with different ammonium stripping systems. By evaluating three configurations, gas diffuser (GD), ambient-temperature stripping (SP) and thermally assisted MEC stripping system (SP + T), this work systematically investigates how operational strategies affect the performance of nitrogen removal and recovery. Key performance indicators such as current density, Faradaic efficiency, specific energy consumption and hydrogen production are quantified and compared as well. Furthermore, organic removal rates, percentage and energy efficiency of organic matter treatment in the anode are also assessed. The findings described highlight the importance of optimizing operational parameters such as temperature and contact surface to maximize ammonium recovery in MECs. The SP + T approach is relevant for bioelectrochemical and wastewater treatment systems aiming to optimize nitrogen management and valorization. Furthermore, the study includes a comprehensive energy analysis and contextualizes the results with respect to conventional ammonia production technologies such as the Haber-Bosch process, among others. Thus, these results are of relevance to the fields of wastewater treatment, nutrient recovery, energy/hydrogen production, environmental biotechnology and circular economy, offering a scalable and energy-efficient solution for nutrient valorization.

Schlagwörter

AmmoniumBioelectrochemical systemCircular economyFertilizerHydrogenMicrobial electrolysis CellWastewater treatment

Kennungen

DOI
41435920
PubMed
41435920
Zeitschrift
Bioresource technology
Jahr
2026
Generic MECProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →