Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MFC

Effect of operating modes on simultaneous anaerobic sulfide and nitrate removal in microbial fuel cell

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Interaktives 3D-ModellKI-angereichert· 78 %

Zusammenfassung

Abstract The effect of operating modes on the simultaneous sulfide and nitrate removal were studied in two-chamber microbial fuel cells (MFCs). The batch and continuous operating modes were compared and evaluated in terms of substrate removal and electricity generation. Upon gradual increase in the influent sulfide concentration from 60 to 1,020 S mg L⁻¹, and the hydraulic retention time decrease from 17.2 to 6 h, the MFC accomplished a good substrate removal efficiency whereby nitrogen and sulfate were the main end products. The removal efficiency of the MFC in the continuous mode was much higher than that in the batch mode, and its current densities in the continuous mode were more stable and higher than in the batch mode, which could be explained by the linear relationship between electrons released by the substrates and accepted on the electrodes. The electricity output in the continuous mode of the MFC was higher than that in the batch mode. MFC's operation in the continuous mode was a better strategy for the simultaneous treatment of sulfide and nitrate.

KI-Zusammenfassung

78 % Konfidenz

This study compared batch and continuous operating modes for simultaneous sulfide and nitrate removal in a two-chamber MFC with graphite felt electrodes. Continuous mode achieved higher substrate removal loading rates (1.18 kg S/(m³·d) at 6 h HRT vs. 0.68 kg S/(m³·d) at 1,020 mg S/L batch), more stable current densities (95–232 mA/m² vs. 23–231 mA/m² with sharp decay), and superior electron-to-electricity conversion efficiency (1.79 C/mmol vs. 1.12 C/mmol). Nitrogen and sulfate were the main end products in both modes. The paper demonstrates that decreasing HRT is more effective than increasing substrate concentration for improving performance.

Zentrale Erkenntnisse

  • Leistung Continuous mode achieved 1.74× higher steady current density (229 mA/m²) at 6 h HRT compared to batch mode at 1,020 mg S/L (120 mA/m²), with current remaining stable rather than decaying 44.7% within 3 hours.

    Was heißt das. Operators should use continuous mode with short HRT (6 h) to maintain stable, high current output; batch mode current decay indicates substrate depletion or product inhibition that continuous feeding prevents.

  • Zielkonflikt Decreasing HRT from 17.2 to 6 h increased sulfide removal loading rate 2.8× (0.42 to 1.18 kg S/(m³·d)) while increasing substrate concentration 17× only increased it 1.7× (0.04 to 0.68 kg S/(m³·d)).

    Was heißt das. Prioritize reducing HRT over increasing influent concentration to boost volumetric treatment capacity; HRT control is a more efficient lever than concentration.

  • Mechanismus Electron-to-electricity conversion efficiency was 1.79 C/mmol in continuous mode versus 1.12 C/mmol in batch mode, a 60% improvement, despite similar substrate removal efficiencies (87–98%).

    Was heißt das. Continuous operation not only treats faster but converts released electrons to usable electricity more efficiently; this is a hidden advantage beyond removal rate.

  • Schwellenwert At 1,020 mg S/L in batch mode, effluent pH dropped to 6.10 ± 0.1, causing process instability, while continuous mode at 300 mg S/L maintained pH 7.0 ± 0.1 throughout.

    Was heißt das. Batch mode accumulates acid (likely from sulfate production) and loses pH control; continuous mode with buffer circulation prevents acidification—a critical stability threshold.

  • Schwellenwert Nitrite accumulated in both modes: batch mode reached 5.61 mg N/L at 178.5 mg N/L influent (3.1% of input); continuous mode reached 2.92 mg N/L at 52.5 mg N/L influent (5.6% of input) at 6 h HRT.

    Was heißt das. Nitrite accumulation increases with decreasing HRT in continuous mode; monitor for incomplete denitrification and consider HRT optimization to avoid NO₂⁻ buildup.

Widersprüche1

Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.

  • Innerhalb der Publikation Substrate removal efficiency is similar between modes, yet electricity generation and loading rates differ substantially.

    Eine Seite

    Batch mode: 'little difference was observed regarding the removal efficiencies of MFCs under different operating modes' with 95–99.5% sulfide removal and 95.6–99.85% nitrogen conversion.

    “In terms of the substrate removal, little difference was observed regarding the removal efficiencies of MFCs under different operating modes (Figs. 1, 3). Both of the MFCs showed a good capacity for simultaneous sulfide and nitrate removal ”
    Andere Seite

    Continuous mode: steady current density 229 mA/m² vs. batch 120 mA/m² (1.9× higher) and loading rate 1.18 kg S/(m³·d) vs. 0.68 kg S/(m³·d) (1.74× higher).

    “The removal loading rate of MFCs in the continuous mode was much higher than that in the batch mode, and the current densities of the MFC in the continuous mode were more stable and higher than that in the batch mode.”

    Einordnung der Autoren. Authors reconcile this by distinguishing removal efficiency (%) from removal loading rate (kg/(m³·d)) and current stability; continuous mode achieves similar % removal but processes more substrate per unit time and electrode area due to steady-state operation and higher volumetric throughput.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch No measurement of N₂O production or accumulation despite denitrification pathway; only N₂ is reported as end product.

    Nitrite accumulation (2.92–5.61 mg N/L) suggests incomplete denitrification; N₂O is a likely intermediate or byproduct but is not quantified. This is critical for greenhouse gas accounting in bioelectrochemical denitrification.

    Versuch. Gas chromatography or membrane inlet mass spectrometry to measure N₂O, N₂, and NO in headspace across HRT range 6–17.2 h and batch time course; correlate with nitrite accumulation.

  • Hoch No cathode potential or anode potential measurement; only external resistance (1,000 Ω) is specified.

    Paper does not report actual electrode potentials, which are critical for understanding denitrification kinetics and N₂O formation risk. Cathode potential controls the reduction pathway (NO₃⁻ → NO₂⁻ → NO → N₂O → N₂).

    Versuch. Potentiostat control with cathode potential varied from −0.2 to −0.8 V vs. Ag/AgCl; measure nitrite, N₂O, and current density at each potential and each HRT.

  • Mittel No dissolved oxygen (DO) measurement in anode or cathode chambers; anaerobic conditions assumed but not verified.

    Batch mode shows pH drop to 6.1 and process instability; DO could be a confounding factor. Continuous mode uses KMnO₄ in cathode but DO in anode is not reported.

    Versuch. Continuous DO probe in anode chamber during batch and continuous operation; correlate DO spikes with current density decay and pH changes.

  • Mittel Catholyte pH not independently controlled; only influent pH maintained at 7.0 ± 0.1.

    Cathode medium is 50 mM PBS at pH 7.0 but no measurement of cathode pH during operation. Denitrification rate and N₂O selectivity are pH-sensitive; catholyte pH may drift.

    Versuch. Monitor cathode pH continuously; test pH range 6.5–8.5 in continuous mode at 6 h HRT to map nitrite and N₂O accumulation vs. pH.

  • Mittel C/N ratio not explicitly controlled or varied; only stoichiometric ratio (5:2 S:N molar) is used.

    Paper does not explore whether C/N imbalance affects denitrification completeness or N₂O formation. Nitrite accumulation suggests N-limitation or incomplete reduction.

    Versuch. Vary S:N molar ratio from 5:2 (stoichiometric) to 10:2 and 2.5:2 at fixed HRT 6 h; measure nitrite, N₂O, and current density.

  • Niedrig No microbial community analysis; only activated sludge inoculum used without characterization of enriched denitrifiers or sulfide oxidizers.

    Paper states 'simultaneous anaerobic sulfide and nitrate removal' but does not identify which organisms perform denitrification vs. sulfide oxidation, or whether they are the same species (as in Lee et al. Pseudomonas sp. C27).

    Versuch. 16S rRNA gene sequencing of anode biofilm at steady state in batch and continuous modes; correlate community composition with nitrite accumulation and N₂O production.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 2 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

0 von 2 extrahierten Zeilen modellierbar

  • 2 nicht kanonisiert (kein kanonischer Slug)
ParameterWertEinheitKonfidenzQuelleModellierbar
Reactor typedual-chamber—80 %
extrahiert
Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Chambers2—80 %
extrahiert
Ausgeschlossen: nicht kanonisiert (kein kanonischer Slug)

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

Two identical two-chamber MFCs (300 mL net volume each) with graphite felt electrodes (36 cm² area) separated by cation exchange membrane were operated in parallel: one in batch mode with influent sulfide 60–1,020 mg S/L (stoichiometric S:N = 5:2), the other in continuous mode with fixed influent (300 mg S/L, 52.5 mg N/L) and HRT varied 17.2–6 h. External resistance 1,000 Ω; cathode medium 50 mM PBS + 100 mg/L KMnO₄ recycled; anode inoculated with activated sludge. Voltage recorded every 1 min; current density normalized to anode area. Effluent analyzed for NO₃⁻–N, NO₂⁻–N, sulfide, sulfate, and pH daily or every 22 h.

Systemkonfiguration

FeldWert
reactor typeMFC
chamber config2-chamber

Leistungskennzahlen

FeldWert
citation count24

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

25 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

50 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

78 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

80 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MFC

Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MFC
System
2
Extrahierte Werte
2014
Jahr

Schlagwörter

  • Nitrate
  • Microbial fuel cell
  • Sulfide
  • Anaerobic exercise
  • Environmental chemistry
  • Hydrogen sulfide

Zitieren

Jing Cai, Ping Zheng, Mahmood Qaisar et al. (2014). Effect of operating modes on simultaneous anaerobic sulfide and nitrate removal in microbial fuel cell. Journal of Industrial Microbiology and Biotechnology. https://doi.org/10.1007/s10295-014-1425-4

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.