MESSAI.iO
Plattform
  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung
Labor
  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Methodik
Anwendungsfälle
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
Wissen
  • Die Wissenschaft
  • Handbuch
  • Whitepaper
Über uns

Sprache

  • Englishen
  • Deutschde

Plattform

  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung

Labor

  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Demo: Ressourcenrückgewinnung

Unternehmen

  • Über uns
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
  • Whitepaper
  • Handbuch
  • API-Dokumentation

Rechtliches

  • Datenschutz
  • Nutzungsbedingungen
  • Nachweise
  • Kontakt

MESSAI · KI für mikrobielle elektrochemische Systeme · © 2026

Jede Zahl auf dieser Website führt auf eine Quelldatei zurück – /proof

Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

← Zurück zur Forschung

Electrochemical insights into the two-step electron transfer mechanism of denitrifying biocathodes

Sen Lin, Wentao Tang, Yihang Xiao, Tianwei Hao

Energy & Environmental Sustainability·2025·24 Zitationen·doi.org/10.1016/j.eesus.2025.02.002
PublikationGrundlagenstudie
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die Parameterbereiche oben ordnen die berichteten Werte trotzdem in die Literaturverteilung ein.

Was gemacht wurde

Systemtyp
FUNDAMENTAL

Was funktioniert hat

Noch keine Ergebniskennzahlen extrahiert.

Zusammenfassung

Microbial electrochemical denitrification (MED) is emerging as a promising approach for nitrogen removal. However, its efficiency is limited by the low-rate extracellular electron transfer (EET) that occurs between microorganisms and electrodes. Due to the complex nature of electrochemical biofilms, the electron transfer mechanism in MED remains unclear. This study performs electrochemical characterization to investigate the EET mechanism of the MED biocathode. Reduction peaks observed at −0.442 ​± ​0.13 ​V and −0.218 ​± ​0.08 ​V vs. Ag/AgCl in cyclic voltammetry indicate the involvement of H 2 ase and cytochrome c in EET process, corroborated by the liner relationship between peak currents and scan rates. The decrease in charge transfer resistance of 19.2 ​% and 51.6 ​% at −0.2 ​V and −0.4 ​V, respectively, in electrochemical impedance spectroscopy fitting, indicates that cytochrome c and H 2 ase function in series to facilitate electron transfer. Elevated abundances of genes associated with H 2 ase and cytochrome c in the electroactive biofilm further support the combination of these two compounds involved in EET process. Findings in this study highlight the importance of H 2 ase and cytochrome c in MED, potentially offering alternative strategies for optimizing the MED system. • Comprehensive electrochemical characterization on denitrifying biocathode. • Direct electron transfer was identified in denitrifying biocathode. • Combination of H 2 ase and cytochrome c is the foundation of direct electron transfer. • An H 2 ase-cytochrome c pathway was proposed.

Schlagwörter

Denitrifying bacteriaElectrochemistryElectron transferMechanism (biology)

Kennungen

DOI
10.1016/j.eesus.2025.02.002
Zeitschrift
Energy & Environmental Sustainability
Jahr
2025
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die Parameterbereiche oben ordnen die berichteten Werte trotzdem in die Literaturverteilung ein.