MESSAI.iO
Plattform
  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung
Labor
  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Methodik
Anwendungsfälle
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
Wissen
  • Die Wissenschaft
  • Handbuch
  • Whitepaper
Über uns

Sprache

  • Englishen
  • Deutschde

Plattform

  • Atlas
  • Research Intelligence
  • Ihr Reproduzierbarkeitsbericht
  • Wissensgraph
  • Protokollgraph
  • Parameterkatalog
  • Mikrobenkatalog
  • Metaanalyse
  • Hunter
  • Erkenntnisse
  • Manuskriptprüfung

Labor

  • 3D-Labor
  • Modellkatalog
  • MESS Explorer
  • Parameterstudie
  • Vorhersagen
  • Experimente
  • Virtueller Sensor
  • Demo: Ressourcenrückgewinnung

Unternehmen

  • Über uns
  • Für Forschende
  • Für Unternehmen
  • Für Institutionen
  • Whitepaper
  • Handbuch
  • API-Dokumentation

Rechtliches

  • Datenschutz
  • Nutzungsbedingungen
  • Nachweise
  • Kontakt

MESSAI · KI für mikrobielle elektrochemische Systeme · © 2026

Jede Zahl auf dieser Website führt auf eine Quelldatei zurück – /proof

Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

← Zurück zur Forschung

Effects of draw solutes on an integrated forward osmosis—Microbial fuel cell system treating a synthetic wastewater

Matthew Ferby, Shiqiang Zou, Zhen He

Water Environment Research·2022·4 Zitationen·doi.org/10.1002/wer.10802
Interaktives 3D-ModellKI-angereichert· 95 %
SystemMFC

KI-Zusammenfassung

95 % Konfidenz

Advanced MFC research focusing on performance. Abstract Microbial fuel cells (MFCs) and forward osmosis (FO) are both attractive and versatile...

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Generic MFCProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →

Was gemacht wurde

Systemtyp
MFC

Was funktioniert hat

Noch keine Ergebniskennzahlen extrahiert.

Zusammenfassung

Abstract Microbial fuel cells (MFCs) and forward osmosis (FO) are both attractive and versatile wastewater treatment technologies that possess disadvantageous qualities that prevent their optimal performance. This study aimed to investigate how draw solute selection for FO treatment would affect MFC performance in a coupled FO‐MFC system. Two types of draw solutes, NH 4 HCO 3 and NaCl, were studied, and it was found that 1.0 M NH 4 HCO 3 (FO‐MFC‐A) and 0.68 M NaCl (FO‐MFC‐B) had similar water fluxes of 6.04 to 3.39 LMH and 6.25 to 3.54 LMH, respectively. The reverse salt flux from the draw decreased the feed solution resistance for both draw solutes, but the FO‐MFC‐A system (0.32 W m −2 ) had a higher maximum power density than the FO‐MFC‐B system (0.26 W m −2 ). The current density for the FO‐MFC‐B system increased due to continuous solution resistance decrease, whereas it remained constant for the FO‐MFC‐A. The difference in Coulombic efficiencies (32.8% vs. 25.6%) but similar Coulombic recoveries (10.2% vs. 11.4%) between the FO‐MFC‐A and FO‐MFC‐B systems suggested that the FO‐MFC‐A might have the inhibited microbial activity by high ammonium/ammonia. The FO‐MFC‐A system had the lower energy consumption for nutrient removal (2.01 kWh kg −1 NH 4 + ‐N) and recovery (8.87 kWh kg −1 NH 4 + ‐N). These results have shown that NH 4 HCO 3 as a draw solute can have advantages of higher power density, higher Coulombic efficiency, and recoverability for draw regeneration, but its potential inhibition on microbial activity must also be considered. Practitioner Points Forward osmosis can be connected to microbial fuel cells for wastewater treatment. Water recovery by forward osmosis can greatly reduce the wastewater volume to microbial fuel cells. Ammonium draw solutes can result in lower volumetric energy consumption. Ammonia inhabitation of anode microbes will decrease organic removal.

Schlagwörter

Microbial fuel cellForward osmosisFaraday efficiencyWastewaterAmmoniumAmmonia

Kennungen

DOI
10.1002/wer.10802
Zeitschrift
Water Environment Research
Jahr
2022
Generic MFCProxy-Topologie
Zum Interagieren tippen
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …
Extraktion

Berichtete Parameter

Noch keine extrahierten Parameter – fordern Sie eine KI-Extraktion an, um diese Publikation mit den Literaturverteilungen zu vergleichen.

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →