Microbial fuel cell (MFC) with nitrite as an electron acceptor in cathode provided a new technology for nitrogen removal and electricity production simultaneously. The influences of influent nitrite concentration and external resistance on the performance of denitrifying MFC were investigated. The optimal effectiveness were obtained with the maximum total nitrogen (TN) removal rate of 54.80±0.01 g m⁻³ d⁻¹. It would be rather desirable for the TN removal than electricity generation at lower external resistance. Denaturing gradient gel electrophoresis suggested that Proteobacteria was the predominant phylum, accounting for 35.72%. Thiobacillus and Afipia might benefit to nitrite removal. The presence of nitrifying Devosia indicated that nitrite was oxidized to nitrate via a biochemical mechanism in the cathode. Ignavibacterium and Anaerolineaceae was found in the cathode as a heterotrophic bacterium with sodium acetate as substrate, which illustrated that sodium acetate in anode was likely permeated through proton exchange membrane to the cathode .

KI-Zusammenfassung

82 % Konfidenz

This study operated a two-chamber denitrifying MFC with NO₂⁻ as the cathode electron acceptor, achieving a maximum TN removal rate of 54.80 g m⁻³ d⁻¹ at 188 mg L⁻¹ influent NO₂—N and 10 Ω external resistance. However, nitrite oxidation to nitrate increased from 0.33% to 26.33% as influent concentration rose, and lower external resistance favored TN removal over power generation. Microbial analysis revealed Proteobacteria (35.72%) dominated, with Afipia and Thiobacillus driving autotrophic denitrification, while Devosia catalyzed unwanted nitrification. The work reveals a critical trade-off: maximizing nitrogen removal requires operating conditions that suppress electricity generation.

Zentrale Erkenntnisse

  • Zielkonflikt TN removal rate increased 104% (from 26.91 to 54.80 g m⁻³ d⁻¹) when influent NO₂—N rose from 60 to 188 mg L⁻¹, but nitrification percentage jumped 79-fold (0.33% to 26.33%), indicating substrate concentration drives both desired denitrification and parasitic nitrite oxidation.

    Was heißt das. Operators must accept nitrification as an unavoidable cost of high-rate nitrogen removal; consider post-treatment or operate at intermediate NO₂—N (60–90 mg L⁻¹) if nitrate accumulation is unacceptable.

  • Zielkonflikt Decreasing external resistance from 200 Ω to 10 Ω increased TN removal rate from 42.25 to 51.51 g m⁻³ d⁻¹ (21.8% gain), but maximum power density (1.71 W m⁻³) occurred at 50 Ω, not at the optimal TN removal resistance.

    Was heißt das. Define your primary objective before setting external resistance: prioritize TN removal at ≤10 Ω, or balance both goals at 25–50 Ω; do not assume the same resistance optimizes both.

  • Schwellenwert Coulombic efficiency dropped from 279.5% at 60 mg L⁻¹ NO₂—N to 140.12% at 188 mg L⁻¹, and fell to 65.05% at 200 Ω external resistance, indicating accumulation of intermediate products (N₂O, NO) that consume electrons without completing reduction to N₂.

    Was heißt das. Monitor coulombic efficiency as an early warning of incomplete denitrification; if it drops below 100%, expect N₂O or NO in the effluent and consider increasing current density or adjusting cathode potential.

  • Leistung Cathode potential remained relatively stable (−35 to −47 mV vs. SHE) across influent NO₂—N concentrations, but shifted from −35.49 mV at 5 Ω to +31.11 mV at 200 Ω, crossing from reducing to oxidizing conditions and correlating with increased nitrate accumulation.

    Was heißt das. Maintain cathode potential below −30 mV vs. SHE to suppress nitrification; if potential drifts positive, reduce external resistance or increase anode-side driving force to restore reducing conditions.

  • Mechanismus Heterotrophic denitrifiers (Ignavibacterium, Anaerolineaceae) were detected in the cathode despite no organic substrate addition, attributed to ~25 mg L⁻¹ COD leakage from the anode through the Nafion membrane, indicating membrane permeability is a hidden source of substrate cross-contamination.

    Was heißt das. If autotrophic denitrification is the goal, minimize anode substrate concentration or use a more selective membrane; if heterotrophic activity is undesired, quantify and account for acetate leakage in mass balances.

Widersprüche2

Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.

  • Innerhalb der Publikation Coulombic efficiency exceeds 100% in most conditions, yet the paper attributes this to oxygen reduction and other oxidants, contradicting the claim that the cathode was maintained under strict anoxic conditions.

    Eine Seite

    Coulombic efficiency >100% (279.5%, 231.53%, 140.12%) at influent NO₂—N 60–188 mg L⁻¹

    “The cathode coulombic efficiency was higher than 100% due to other oxidizing substances (e.g., oxygen) in the cathode functioning as a terminal electron acceptor”
    Andere Seite

    Text states 'Under the condition of strict measures to maintain the anoxic condition in the cathode'

    “Under the condition of strict measures to maintain the anoxic condition in the cathode, but the cathode still showed obvious nitrite nitrification.”

    Einordnung der Autoren. Authors acknowledge that despite anoxic operation intent, trace oxygen and other oxidants (possibly produced electrochemically) persist and compete with NO₂⁻ reduction, explaining >100% efficiency. This is not a true contradiction but rather an unresolved operational challenge: anoxic conditions were not fully achieved despite effort.

  • Innerhalb der Publikation Nitrification is attributed to both biological (Devosia) and electrochemical processes, but the paper provides no quantitative split or clear operating window to suppress one or the other.

    Eine Seite

    Nitrification percentage increases from 0.33% to 26.33% as influent NO₂—N rises from 60 to 188 mg L⁻¹

    “the nitrification percentage increased from 0.33 to 26.33% meanwhile”
    Andere Seite

    Text states 'The small part of nitrite to nitrate transformation might be caused by biological nitrification... While the other part of the nitrite transformation also might be oxidized by other electrochemical processes'

    “The small part of nitrite to nitrate transformation might be caused by biological nitrification in this study (reaction 4) because of trace oxygen in the cathode. While the other part of the nitrite transformation also might be oxidized by o”

    Einordnung der Autoren. Authors speculate on dual mechanisms but do not experimentally isolate them. The paper does not test conditions (e.g., cathode potential, DO control, pH) that would suppress one pathway over the other, leaving the relative contribution and control strategy unclear.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch No systematic study of cathode potential control (potentiostatic operation) to suppress nitrification. The paper only reports potentials as a consequence of external resistance variation, not as an independent control variable.

    Cathode potential ranges from −35 to +31 mV across resistances, and positive potentials correlate with nitrification; setting potential <−100 mV might suppress Devosia activity, but this was never tested.

    Versuch. Operate at fixed cathode potentials (−200, −100, −50, 0, +50 mV vs. SHE) at constant influent NO₂—N (188 mg L⁻¹) and measure TN removal, nitrification %, and coulombic efficiency. Identify the threshold potential below which nitrification drops to <5%.

  • Hoch No investigation of dissolved oxygen (DO) control or measurement in the cathode. The paper mentions 'trace oxygen' as a cause of nitrification but never quantifies DO or tests anoxic vs. microaerobic conditions.

    Text states 'DO was determined using Hach-HQ30d' but no DO data are reported for the cathode. Coulombic efficiency >100% and presence of aerobic Truepera (39.64%) suggest DO is present but uncontrolled.

    Versuch. Measure and control cathode DO (target 0, 0.5, 1, 2 mg L⁻¹) while holding influent NO₂—N at 188 mg L⁻¹ and external resistance at 10 Ω. Quantify nitrification rate and microbial community shift as a function of DO.

  • Mittel No exploration of catholyte pH as an independent variable. Effluent pH varies from 0.85 to 1.18 across conditions, but the paper does not test whether pH control (e.g., buffering to pH 6–8) would suppress nitrification or improve denitrification kinetics.

    Effluent pH correlates with TN removal rate (Table 2), but causality is not established. Low pH may inhibit nitrifiers or shift denitrification pathway selectivity.

    Versuch. Operate at fixed influent NO₂—N (188 mg L⁻¹) and external resistance (10 Ω) while controlling catholyte pH at 6.0, 7.0, 8.0, and 9.0 using buffer or acid/base dosing. Measure TN removal, nitrification %, and coulombic efficiency.

  • Mittel No testing of intermediate influent NO₂—N concentrations (e.g., 100–150 mg L⁻¹) to identify the optimal point where TN removal is maximized and nitrification is minimized. Only three concentrations (60, 87, 188 mg L⁻¹) were tested.

    TN removal increases monotonically with NO₂—N, but nitrification also increases; a sweet spot may exist between 60 and 188 mg L⁻¹ where the trade-off is optimized.

    Versuch. Test influent NO₂—N at 60, 90, 120, 150, 180 mg L⁻¹ at fixed external resistance (10 Ω) and measure TN removal rate and nitrification %. Plot both metrics to identify the concentration that maximizes TN removal while keeping nitrification <10%.

  • Mittel No measurement or control of hydraulic retention time (HRT) as an independent variable. Flow rate was fixed at 3 mL h⁻¹ (HRT ~8 h), but longer HRTs might allow more complete denitrification to N₂ and reduce intermediate accumulation.

    Coulombic efficiency drops to 65% at high external resistance, suggesting incomplete denitrification; longer contact time might shift the pathway toward N₂ completion.

    Versuch. Vary flow rate (1, 2, 3, 5 mL h⁻¹; HRT 24, 12, 8, 5 h) at fixed influent NO₂—N (188 mg L⁻¹) and external resistance (10 Ω). Measure TN removal, N₂O/NO accumulation (via coulombic efficiency), and nitrification %.

  • Hoch No direct measurement of N₂O or NO in the cathode effluent. The paper infers their presence from low coulombic efficiency (<100%) but does not quantify them, leaving the magnitude of incomplete denitrification unknown.

    At 200 Ω external resistance, coulombic efficiency is only 65%, implying ~35% of electrons go to N₂O/NO instead of N₂, but the actual N₂O/NO concentrations are not reported.

    Versuch. Use gas chromatography or membrane inlet mass spectrometry (MIMS) to measure N₂O and NO concentrations in the cathode effluent at external resistances 5, 10, 50, 100, 200 Ω. Correlate with coulombic efficiency to quantify the denitrification pathway distribution.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 59 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

12 von 59 extrahierten Zeilen modellierbar

  • 33 nicht kanonisiert (kein kanonischer Slug)
  • 5 kein SI-Wert
  • 4 außerhalb physikalischer Grenzen
  • 5 nicht als modellierbar markiert
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Electrode chamber volume×2160cm³95 %
geometric calculation
"Each chamber was filled with rectangular graphite felts (140 mm long, 11.7 mm wid…" · replicates_n=1, condition_hint=design parameter, dual-chamber MFC, electrode_material=graphite feltAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Influent flow rate×23mL h⁻¹95 %
directly_reported
"The flow rate of influent was maintained at 3 mL h⁻¹." · replicates_n=1, condition_hint=operational parameterAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Total Ammonia Nitrogen Removal Rate54,8 ± 0,01 (SD)g m⁻³ d⁻¹95 %
calculated from influent/effluent no₂ and no₃
"TN removal (g m⁻³ d⁻¹) 54.80 ± 0.01 at influent 188.12 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: kein SI-Wert
External Load1.000Ω95 %
directly_reported
"The initial resistance was set at 1000 Ω for 15 days" · startupModellierbar
External Load100Ω95 %
directly_reported
"then turned to 100 Ω for about a month" · startupModellierbar
Long-term operation external resistance10Ω95 %
directly_reported
"Then, the resistance was kept constant at 10 Ω, and maintained for 240 days." · steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Cathode initial NO₂ concentration150mg L⁻¹95 %
directly_reported
"The cathode solution was composed of NaNO2 (0.15 g L⁻¹)" · replicates_n=1, condition_hint=cathode medium composition, substrate_normalization_basis=as_compoundAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Anode substrate concentration3.840mg L⁻¹95 %
directly_reported
"The anode solution was composed of CH3COONa (3.84 g L⁻¹)" · substrate=sodium acetateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Effluent NO₂—N0mg L⁻¹90 %
standard methods
"Effluent NO₂—N (mg L⁻¹) 0 at influent 60.11 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Influent NO₂—N60,1 ± 0,34 (SD)mg L⁻¹90 %
standard methods
"Influent NO₂—N (mg L⁻¹) 60.11 ± 0.34" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Influent NO₂—N86,7 ± 0,61 (SD)mg L⁻¹90 %
standard methods
"Influent NO₂—N (mg L⁻¹) 86.65 ± 0.61" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Influent NO₂—N188 ± 2,3 (SD)mg L⁻¹90 %
standard methods
"Influent NO₂—N (mg L⁻¹) 188.12 ± 2.3" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Effluent NO₂—N16,7 ± 0,59 (SD)mg L⁻¹90 %
standard methods
"Effluent NO₂—N (mg L⁻¹) 16.72 ± 0.59 at influent 188.12 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Incremental NO₃—N49,5 ± 0,5 (SD)mg L⁻¹90 %
standard methods
"1 NO₃—N = incremental nitrate (mg L⁻¹) 49.5 ± 0.5 at influent 188.12 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Startup voltage criterion200mV90 %
voltmeter
"When the output voltage of the MFC was stable and reached 200 mV with external r…" · startupAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Nitrification Percentage26,3%85 %
calculated from no₂ and no₃ measurements
"Nitrification Percentage (%) 26.33 at influent 188.12 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Effluent NO₂—N26,6 ± 0,85 (SD)mg L⁻¹85 %
standard methods
"the concentrations of nitrite in effluent and the TN removal rate decreased signifi…" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Effluent NO₂—N1,26 ± 0,09 (SD)mg L⁻¹85 %
standard methods
"concentrations of nitrite in effluent decreased from 26.55 ± 0.85 to 1.26 ± 0.09 m…" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Effluent NO₃—N52,8 ± 0,48 (SD)mg L⁻¹85 %
standard methods
"the nitrate concentration in effluent increased from 52.84 ± 0.48 to 92.62 ± 1.47 …" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Effluent NO₃—N92,6 ± 1,47 (SD)mg L⁻¹85 %
standard methods
"nitrate concentration in effluent increased to 92.62 ± 1.47 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Ignavibacteriae proportion17,1%85 %
dgge analysis of 16s rrna genes
"Ignavibacterium(bands 5 and 22) similar to Phylum Ignavibacteriae (17.14%)" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Coulombic efficiency232 ± 28,5 (SD)Außerhalb des physikalischen Bereichs, Quelle prüfen%85 %
calculation per logan et al. (2006)
"Columbic efficiency (%) 231.53 ± 28.53 at influent NO₂—N 86.65 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateAusgeschlossen: außerhalb physikalischer Grenzen
Current Density (Volumetric)18 ± 0,81 (SD)A m⁻³85 %
ohm's law from voltage and external resistance
"Current density (A m⁻³) 18.02 ± 0.81 at influent NO₂—N 60.11 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateModellierbar
Power Density Volumetric0,518 ± 0,035 (SD)W m⁻³85 %
p = i·v calculation
"Power density (W m⁻³) 0.518 ± 0.035 at influent NO₂—N 60.11 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateModellierbar
Current Density (Volumetric)19,3 ± 1,07 (SD)A m⁻³85 %
ohm's law from voltage and external resistance
"Current density (A m⁻³) 19.25 ± 1.07 at influent NO₂—N 86.65 mg L⁻¹" · T=32°C, substrate=sodium acetate, steady_stateModellierbar
25 von 57 angezeigt

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

A two-chamber MFC with graphite felt electrodes and Nafion-117 membrane was operated in batch mode with sodium acetate anode feed and nitrite cathode feed. Influent NO₂—N concentration (60–188 mg L⁻¹) and external resistance (5–200 Ω) were varied sequentially at constant flow (3 mL h⁻¹) and temperature (32°C). Nitrogen species (NO₂⁻, NO₃⁻) were measured by standard methods; voltage, current, and cathode potential were logged continuously. Cathode biofilm was analyzed by PCR-DGGE after 9 months of operation at 188 mg L⁻¹ NO₂—N and 10 Ω resistance.

Systemkonfiguration

FeldWert
reactor typeMFC
chamber config2-chamber

Betriebsbedingungen

9 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-0bd85d5ea89212b5——————startup1000——
v2-22a6a86a28c78b82——————startup100——
v2-61edd420edd29211———sodium acetate3840—————
v2-64c78bb05c3fab7332——sodium acetate3840—steady_state200——
v2-7ab70802d1d9341b32——sodium acetate3840—steady_state5——
v2-8ed53b53922424e232——sodium acetate3840—steady_state50——
v2-9548d77515f5d1e932——sodium acetate3840—steady_state10——
v2-d41d8cd98f00b204——————————
v2-f44452a66e2ca586——————steady_state10——

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

KI-Konfidenz

82 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

86 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

3D-Modell wird geladen …

Repräsentatives Modell, generisches MFC

Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

MFC
System
65,1Prozent
Bestes Ergebnis · Coulomb-Effizienz
59
Extrahierte Werte
2016
Jahr

Schlagwörter

  • Denitrifying bacteria
  • Nitrite
  • Microbial fuel cell
  • Environmental chemistry
  • Microbiology
  • Denitrification

Zitieren

Huimin Zhao, Jianqiang Zhao, Fenghai Li et al. (2016). Performance of Denitrifying Microbial Fuel Cell with Biocathode over Nitrite. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2016.00344

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen